User manual KONICA CA-2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CA-2000. We hope that this KONICA CA-2000 user guide will be useful to you.

Lastmanuals help download the user guide KONICA CA-2000.


Mode d'emploi KONICA CA-2000
Download

You may also download the following manuals related to this product:

   KONICA CA-2000 BROCHURE (1528 ko)

Manual abstract: user guide KONICA CA-2000

Detailed instructions for use are in the User's Guide.

[. . . ] 2D Color Analyzer CA-2000 Series Instruction Manual Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding safety warning or precaution. Read the sentence carefully to ensure safe and correct use. The instruction must be strictly adhered to. Never disassemble this instrument. Notes on this manual l Copying or reproduction of all or any part of the contents of this manual without KONICA MINOLTA SENSING's permission is strictly prohibited. [. . . ] Also, do not place heavy object on power cord, or damage or modify one. Any of these may cause fire or electric shock due to damage to power cord. Do not disassemble or modify this instrument or AC adapter. Doing so may cause fire or electric shock. Should this instrument or AC adapter be damaged or smoke or odd smell be generated, do not keep using one without correction. Switch power off immediately, unplug AC adapter from AC outlet in such case. If operated on battery, remove battery and contact the nearest KONICA MINOLTA SENSING authorized service facility. Caution (Failure to adhere to following points may result in injury or damage to instrument or other property. ) Use this instrument near AC outlet for easy plugging or unplugging in using AC adapter. Connection procedure 1. Be sure that power switch is OFF ([ ] mark pressed). 2. Connect AC adapter plug to AC adapter input terminal of body. 3. Plug AC adapter to outlet (AC 100 V-240 V , 50 Hz-60 Hz). l Insert AC adapter plug all the way seated in AC outlet. ~ ON (|) / OFF ( ) of Power Switch To ON Installing 1. Press [|] side of power switch to ON. To OFF 2. Press [ ] side of power switch to OFF after completion of measurement. Connecting with PC Before connecting CA-2000 body with PC, install software CA-S20w in PC. (For detail, see the instruction manual for data management software CA-S20w. ) Use accessory USB cable (3 m) IF-A for this purpose. No problem would occur if USB cable is plugged or unplugged while power is on, but instruction here indicates the case when power is off. Operation procedure 1. Connect USB cable to USB connector on body. Check whether the connection is secure. Communication interface of this instrument complies with USB2. 0. Always hold plug portion of USB cable in unplugging. Match the USB cable plug shape with the slot of either body or PC before inserting. Any USB port is usable on PC if it has multiple, but abnormal operation could be detected on PC in case that it is used together with other USB device than CA-2000. 9 20 Measurement 2 Measuring Flow 1. Attach lens corresponding to measurement target. p. 23 p. 6-7 p. 24 p. 24-25 Measurement 3. Adjust CA-2000 position to measurement object. A d j u s t p o s i t i o n a n d d i r e c t i o n o f C A -2 0 0 0 t o measurement object and focus while watching the finder view on software CA-S20w. Adjust shutter speed as needed if the finder view is not good. Set up measurement condition with software CA-S20w. (For detail, see the instruction manual for data management software CA-S20w. ) l l l l Lens Lens position (Distance) (p. 25-27) Measuring range Exposure mode and light intensity adjustment (Selection of shutter speed, signal amplification circuit gain, and ND filter) Light intensity can be adjusted with 3 factors; shutter speed, signal amplification circuit gain, and ND filter for this series. Adjustment of these is indispensable to gain appropriate light intensity for measurement. [. . . ] , 770 mm/2, 000 mm Approx. Measurement luminance 0. -00, 000 cd/m2 0. -00, 000 cd/m2 0. 5-00, 000 cd/m2 0. 5-00, 000 cd/m2 -00, 000 cd/m2 range (including ND filter use) Single : Approx. or more; 6-time integration: Measurement time (*2) Approx. or more Luminance Accuracy (*3) Chromaticity ±3 % ±0. 005 ±3 % ±0. 005 ±3 % ±0. 005 ±3 % ±0. 005 ±3 % ±0. 005 Temperature/humidity characteristics (within the operating temperature/humidity range) Luminance: ±2% of change compared to reference temperature and relative humidity of 23°C and 40% Chromaticity: ±0. 004 of change compared to reference temperature and relative humidity of 23°C and 40% 0. 5 % 0. 00 0. 5 % 0. 00 ±2 % ±0. 002 ±3 % ±0. 003 0. 5 % 0. 00 ±2 % ±0. 002 ±3 % ±0. 003 0. 5 % 0. 00 ±2 % ±0. 002 ±3 % ±0. 003 0. 5 % 0. 00 ±2 % ±0. 002 ±3 % ±0. 003 Repeatability Luminance (*4) Chromaticity Luminance (*6) ±2 % Inter-point error (*5) Chromaticity (*6) ±0. 002 Luminance (*7) ±3 % Chromaticity (*7) ±0. 003 Other functions Interface Operating temperature and humidity range (*) Storage temperature and humidity range (*) Body only Size Weight Power source Lens Hood Standard accessories Hood Cap Calibration data DVD Other Optional accessories When lens and hood are attached Interval measurement, Measurement sync (Synchronization frequency selectable), Integration function, Enhanced nonuniformity display, Conversion of enhanced nonuniformity image into numerical values (statistical values, etc. ) USB 2. 0 0-30°C, Relative humidity 70% or less/No condensation 0-30°C, Relative humidity 70% or less/No condensation 30-30°C, Relative humidity 55% or less/No condensation 60 (W) × 64 (H) × 99 (D) mm (Height including handle: 2 mm) 224 (D) mm 29 (D) mm 224 (D) mm 230 (D) mm 237 (D) mm 3. 5 Kg approx. (when standard lens and hood are attached) Exclusive AC adapter (00 - 240 V~, . 2 A, 50-60 Hz) CA-A6 CA-A7 CA-A69 CA-A75 CA-A6 CA-A7 CA-A70 Included with each lens. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CA-2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CA-2000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag