User manual KONICA CM-600D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CM-600D. We hope that this KONICA CM-600D user guide will be useful to you.

Lastmanuals help download the user guide KONICA CM-600D.


Mode d'emploi KONICA CM-600D
Download

You may also download the following manuals related to this product:

   KONICA CM-600D BROCHURE (386 ko)
   KONICA CM-600D BROCHURE 2 (1620 ko)

Manual abstract: user guide KONICA CM-600D

Detailed instructions for use are in the User's Guide.

[. . . ] Spectrophotometer CM-700d/600d E Instruction Manual Es Manual de instrucciones Notes on this Manual · Copying or reproduction of all or part of the contents of this manual without KONICA MINOLTA SENSING's permission is strictly prohibited. · The contents of this manual are subject to change without prior notice. · Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact a KONICA MINOLTA SENSING-authorized service facility. [. . . ] Settings The setting values are the same as those for "Illuminant 1" and "None". 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Disp. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Disp. Cond. > screen without changing the setting. E-41 Condition Setting Setting the Measurement Conditions To set measurement conditions, select "Meas. Cond. " from the <Option> screen. You can select or specify the following four items as the measurement conditions: · Mode: Select the specular component mode. · Wait Time: Specify the delay between the press of the measuring button and the flash of the lamp. · Auto Ave. : Specify the number of measurements for auto averaging. · Manual Ave. : Specify the number of measurements for manual averaging. [Setting Procedure] 1 Hold down the [MENU] button and press the button of the cross key. The <Option> screen is displayed. 2 Use the or button of the cross key to move the cursor to "Meas. Cond. " and then press the [SAVE/SEL] button. The <Meas. Cond. > screen is displayed. Note When setting of "Cond" is "ON" (refer to page E-56), "Disp. Cond" cannot be selected. · The <Meas. Cond. > screen shows the current settings. 3 After you set the measurement conditions, press the [TARGET] (Back) button to return to the <Option> screen. E-42 Condition Setting Mode Select the specular component mode. [Setting Procedure] Start the procedure from the <Meas. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Mode" and then press the [SAVE/SEL] button. The <Mode> screen is displayed. 2 Use the or button of the cross key to move the cursor to the desired item. Settings SCI: Specular component included SCE: Specular component excluded SCI+SCE: Automatic SCI/SCE switching 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Meas. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Meas. Cond. > screen without changing the setting. E-43 Condition Setting Wait Time Specify the delay between the press of the measuring button and the flash of the lamp. [Setting Procedure] Start the procedure from the <Meas. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Wait Time" and then press the [SAVE/SEL] button. The <Wait Time> screen is displayed. 2 Use the or button of the cross key to specify a value. · Use the or button of the cross key to move the cursor to the digit on the left or right. Setting Sec. [0. 0 to 3. 0]: To eliminate the influence of instrument shake, provide a period between the press of the measuring button and the flash of the lamp for measurement in increments of 0. 1 seconds. When 0. 0 seconds is specified, measurement starts immediately. 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Meas. Cond. > screen. Note If you press the [TARGET] (Back) button without pressing the [SAVE/SEL] button, you return to the <Meas. Cond. > screen without changing the setting. E-44 Condition Setting Auto Averaging (Auto Ave. ) Specify the number of measurements for auto averaging. [Setting Procedure] Start the procedure from the <Meas. Cond. > screen. 1 Use the or button of the cross key to move the cursor to "Auto Ave. " and then press the [SAVE/SEL] button. The <Auto Ave. > screen is displayed. 2 Use the or button of the cross key to specify a value. · Use the or button of the cross key to move the cursor to the digit on the left or right. Setting Times [1 to 10]:Specify the number of measurements, from 1 to 10, to perform when using auto averaging. 3 Press the [SAVE/SEL] button. The selection is confirmed and the screen returns to the <Meas. [. . . ] If you want to control the instrument from a PC, you need software that allows the connection and operation of the instrument. If you want to develop your own program to control the instrument from a PC, contact a KONICA MINOLTA SENSING-authorized service facility. E-115 Principles of Measurement Initial Settings * Initialization of the instrument will reset the settings to the initial values shown in the table below. The measured data, target color data and tolerances set for each target color are protected and not cleared by the initialization. * The zero calibration data will be reset to the factory-set data. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-600D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-600D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag