User manual KONICA CS-200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CS-200. We hope that this KONICA CS-200 user guide will be useful to you.

Lastmanuals help download the user guide KONICA CS-200.


Mode d'emploi KONICA CS-200
Download

You may also download the following manuals related to this product:

   KONICA CS-200 BROCHURE (2840 ko)
   KONICA CS-200 BROCHURE 2 (2466 ko)

Manual abstract: user guide KONICA CS-200

Detailed instructions for use are in the User's Guide.

[. . . ] CHROMA METER CS-200 Instruction Manual Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding a safety warning or note. Read the sentence carefully to ensure safe and correct use. The operation must never been performed. The instruction must be strictly adhered to. [. . . ] Setting remains even after switching OFF (O). 55 CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 448 y 0. 448 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC> 200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ Backlight ON/OFF Whether turning backlight on LCD is ON or OFF is selectable. Operation Procedure Setting BACK LIGHT 2 1 3 CH00:<DEFAULT> 1. Press ESC key when menu or target value setting menu appears. Measurement screen appears on LCD screen. Lv 20. 80cd/m2 x 0. 4476 y 0. 4477 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 2. Make sure that [ ] appears on left bottom indicating this instrument has not been set for SHIFT mode. If [SFT] appears instead, it means that instrument is to operate in SHIFT mode. Press SHIFT key to cancel SHIFT mode. 3. Press BACKLIGHT key. If backlight has been on, it is switched off, and off, switched on. This has been set for [ON] by the time switching this instrument ON (|) after the shipment from factory. Setting remains even after switching OFF (O). 56 Setting BACK LIGHT 57 Setting Sleep Mode Sleep mode can be set for saving electric power consumption for the case that key has not been operated or communication has not been done for more than 30 minutes. Operation Procedure Setting SLEEP MODE 2 3 1, 7 4, 6 CH00:<DEFAULT> 5 Lv 20. 80cd/m2 x 0. 4476 y 0. 4477 <MODE>SINGLE [ ] [ 2° ] 1. Press ESC key when menu or target value setting menu appears. Measurement screen appears on LCD screen. <ANGL> 1° VIEW <SPD> AUTO <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 2. Make sure that [ ] appears on left bottom indicating this instrument has not been set for SHIFT mode. If [SFT] appears instead, it means that instrument is to operate in SHIFT mode. Press SHIFT key to cancel SHIFT mode. 3. Press MENU key three times. Menu 3/4 screen appears on LCD screen. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 4. Press ENTER key. Inversion cursor moves from [SLEEP MODE] to right to change setting for sleep mode. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 58 5. Press either or to set either for [ON] or [OFF]. If [ON] is set, this instrument operates in sleep mode when key operation or communication has not been done for more than 30 minutes. "SLEEP MODE" appears on LCD in sleep mode. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 ON Setting BREAK : [ESC] [ 2° ] SLEEP MODE SLEEP MODE If measurement button or any key is pressed, original screen appears after "PLEASE WAIT". CH02:<DEFAULT> <ANGL> 1° VIEW <SPD> AUTO Lv ------cd/m2 <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM x 0. 4476 PLEASE<MEMORY DATA> WAIT. . . y 0. 4477 ] [ 2° ] MOOO:(NO DATA) Lv -----x 0. 4155 y 0. 4242 <MODE>SINGLE [ 6. Press ENTER key. Inversion cursor returns to [SLEEP MODE] to fix setting. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 ON BREAK : [ESC] [ 2° ] 7. Press ESC key to return to measurement screen. This has been set for [ON] by the time switching this instrument ON (|) after the shipment from factory. Setting remains even after switching OFF (O). 59 CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 448 y 0. 448 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC> 200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ Setting Internal Clock This instrument is equipped with internal clock to record measurement time. Although measurement date and time are not indicated in this instrument, one can be output together with measurement value when this unit is controlled with PC. If used with either standard accessory data management software CS-S10w Standard or optional CS-S10w Professional, measurement time is to display together with measurement value. Setting DATE & TIME Operation Procedure 6 2 3 1, 9 8 4, 5 1. Press ESC key when menu or target value setting menu appears. Measurement screen appears on LCD screen. CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 4476 y 0. 4477 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC>200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 2. Make sure that [ ] appears on left bottom indicating this instrument has been set for SHIFT mode. If [SFT] appears instead, it means that instrument is to operate in SHIFT mode. Press SHIFT key to cancel SHIFT mode. 3. Press MENU key three times. Menu 3/4 screen appears on LCD screen. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 60 4. Press either or to select [DATE & TIME] and then ENTER key. < DATE & TIME > screen appears. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF Setting BREAK : [ESC] [ 2° ] 5. Press either or set arbitrary value. to key for larger number. If kept pressed, value continuously increases. If kept pressed, value continuously becomes small. SLEEP MODE DATE &2005Y/01M/01D TIME BUZZER 00:00:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> DATE & TIME OFF 6. Press key to move cursor to second digit position. Cursor shall not move if unsettable number has been entered. SLEEP MODE DATE &2005Y/01M/01D TIME BUZZER 00:00:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> OFF 7. Repeat the procedures from 5. as necessary. Year range available to set is 2000 to 2099. If you enter month and day that do not exist in calendar, error occurs. Time range available to set is 00:00:00 to 23:59:59. If you enter incorrect time, error occurs. Press ESC key to stop. SLEEP MODE DATE &2005Y/02M/01D TIME BUZZER 15:52:00 VERSION [ ] BREAK : [ESC] [ 2° ] <DATE & TIME> OFF 8. Press [ENTER] key. Menu 3/4 screen appears on LCD screen indicating internal clock has been set. SLEEP MODE DATE & TIME BUZZER VERSION [ ] <MENU> 3/4 OFF BREAK : [ESC] [ 2° ] 9. Press ESC key to return to measurement screen. Internal clock adjustment has been completed before shipment form factory. CH00:<DEFAULT> Lv 20. 80cd/m2 x 0. 448 y 0. 448 <MODE>SINGLE [ ] [ 2° ] <ANGL> 1° VIEW <SPD> AUTO <SYNC> 200. 00Hz <LENS>STANDARD <MEM> AUTO NUM <MEMORY DATA> MOOO:(NO DATA) Lv -----x -----y ------ 61 62 Measurement Preparation 63 Calibration Calibration Channel There are 21 calibration channels from CH00 to CH20. Following settings are available for all channels. (1) Correction coefficient of user calibration (2) Target color (3) CH ID name These are commonly used among each measurement mode of Lvxy, Lvu'v', LvTuv, XYZ, and dominant wavelength in one channel. CH00 is for measurement based upon KONICA MINOLTA SENSING's calibration standard. Its calibration correction coefficient has been set and is unchangeable. [. . . ] Hasn't remote mode been cancelled? 100 101 Has prepared program been correct? - Switch ON to charge backup battery. 6 Backup battery is to fulfill its function after fully charged for approx. Shelf life of backup battery is 10 years under general use, but replacement is needed should memory disappears soon after full charge. For replacing backup battery, please contact the nearest KONICA MINOLTA SENSING authorized service facility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CS-200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CS-200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag