User manual KONICA VI-910

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA VI-910. We hope that this KONICA VI-910 user guide will be useful to you.

Lastmanuals help download the user guide KONICA VI-910.


Mode d'emploi KONICA VI-910
Download

You may also download the following manuals related to this product:

   KONICA VI-910 BROCHURE (7353 ko)

Manual abstract: user guide KONICA VI-910

Detailed instructions for use are in the User's Guide.

[. . . ] NON-CONTACT 3D DIGITIZER VIVID 910/VI-910 Instruction Manual (HARDWARE) NOTE The VI-910 is model name for Europe and the VIVID 910 is model name for other countries. Please note that the VIVID 910 model name is intended only for reference with this manual. Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as result of incorrect use of the instrument. Denotes a sentence regarding safety warning or note. Read the sentence carefully to ensure safe and correct use. The operation must never been performed. [. . . ] * Make sure that screw washers are fitted into the dents on the base of the instrument. If you have removed the handle from the top of the instrument, attach it to the base of the instrument. 4 Tripod Base Plate 22 Notes When Using the Instrument with Tripod 2. Mounting the Instrument to the Panhead After you have attached the tripod base plate to the instrument, they need to be mounted to the recommended panhead as explained below. First, remove the accessory plate from the panhead, attach it to the instrument, then attach both to the panhead. Memo Three screw holes are provided on the back of the tripod base plate (the side with rubber feet), to allow mounting the tripod base plate to the panhead. [Attaching the Accessory Plate] 1 2 Remove the accessory plate from the panhead. Place the top of the accessory plate on the tripod base plate (attached to the instrument), and secure them with two screws (U3/8, supplied with the accessory plate). U3/8 Screw Accessory Plate [Attaching to the Panhead] 1 2 Make sure that the tripod/panhead is secured in place. Remove the rubber feet on the base plate with the use of a hexagonal wrench. Memo Remove the two rubber feet located at the rear. Note · If the instrument is to be removed from the tripod/panhead and located on the base plate, attach the rubber feet. · Store the rubber feet in a safe place after removal. 3 4 Slide the accessory plate (attached to the tripod base plate on the instrument) into the panhead. Tighten the slide fixing knob to firmly secure the accessory plate to the panhead. Memo Refer to the tripod/panhead instruction manual for details on using the accessory plate locking knob. 23 Notes When Using the Instrument with Tripod 24 Chapter 3 Operation 25 Replacing the Lens Before starting acquisition of images, the lens may need to be replaced according to the size and distance to the object. Relationship between Measurement Distance and Object With the VIVID 910, three types of lens are available: wide-angle lens, middle-angle lens and telescopic lens. A lens suitable for the size of the object and distance must be used. Memo The closer the object to the VIVID 910, the higher the measurement accuracy is. On the other hand, influences of shades produced due to roughness on the surface of the object can be reduced if the object is positioned far from the VIVID 910. Select the most suitable lens by referring to the table given below. WIDE Lens Measurement Distance Horizontal Object Size Vertical 600 367. 0 275. 2 800 486. 6 364. 9 1000 606. 2 454. 6 1200 725. 8 544. 4 2000 1204. 2 903. 2 Unit (mm) MIDDLE Lens Measurement Distance Horizontal Object Size Vertical 600 204. 7 153. 6 800 270. 6 203. 0 1000 336. 5 252. 4 1200 402. 4 301. 8 2500 830. 6 622. 9 Unit (mm) TELE Lens Measurement Distance Horizontal Object Size Vertical 600 113. 9 85. 4 800 151. 0 113. 2 1000 188. 0 141. 0 1200 225. 1 168. 8 2500 465. 9 349. 4 Unit (mm) 26 Replacing the Lens Replacing Procedure The currently installed lens can be verified by the status information. To replace the lens with another one, follow the procedure given below. · Only the lenses supplied as standard accessories with the VIVID 910 can be used. (They are not compatible with other VIVID models since they have been calibrated with the VIVID 910 only. ) · Since the VIVID 910 is a precision instrument, do not leave it without lens when replacing the lens. · If you replace the lens before saving the image data, the image data will be lost. Before replacing the lens, all the necessary operations (e. g. · Do not touch the lens surface with fingers. · If dust or dirt has collected on the lens surface, remove it using a camera air blower etc. · Dust or dirt on the lens mount surface may produce incorrect measurement data. In this case, wipe the lens mount surface with a clean, dry cloth and then blow it with a camera air blower etc. · Dust and dirt collected on the lens mount surface on the body side must also be removed with a camera air blower etc. Note Ref. For display of the status information, refer to page 51. [Replacing Procedure] 1 Remove the lens hood. Memo The lens hood can be fixed with its bayonet mount. 2 Turn the lens fixing ring counter-clockwise to loose it completely. Memo The lens fixing ring can be fixed with its screw mount. 27 Replacing the Lens 3 Hold the external edge of the fixing ring and pull it out. Memo Hold the ring with your finger located near the red mark on the lens. Attach the lens cap to the removed lens, place it in the lens case and keep it in a safe place. Note The following information will appear in the viewfinder as shown on the right. Check the serial number of each lens displayed. CHANGE LENS TELE S/N MIDDLE S/N WIDE S/N PRESS ANY KEY 2001005 2001005 2001005 4 Attach the desired lens. [. . . ] If the problem still does not disappear, contact a Minolta-authorized service facility. Set the terminator to "ENABLE". TERMINATE ERROR PRESS ANY KEY SET TERMINATE ENABLE UNKNOWN MEMORY CARD PLEASE INSERT ANOTHER MEMORY CARD OR PRESS ANY KEY WB ERROR LIGHT IMPROPER PRESS ANY KEY SCSI terminator error has occurred. Press any key and set the terminator to "ENABLE". The currently inserted memory card is not suitable for the VIVID 910. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA VI-910

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA VI-910 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag