User manual KUSSMAUL 091-96

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KUSSMAUL 091-96. We hope that this KUSSMAUL 091-96 user guide will be useful to you.

Lastmanuals help download the user guide KUSSMAUL 091-96.


Mode d'emploi KUSSMAUL 091-96
Download
Manual abstract: user guide KUSSMAUL 091-96

Detailed instructions for use are in the User's Guide.

[. . . ] BOOK# 091-96, 3-3-98 INSTRUCTION MANUAL LOAD MANAGER 1H UNDER-VOLTAGE DETECTOR RELAY WITH HYSTERESIS MODEL #091-96-XX A BATTERY VOLTAGE MONITOR WHICH DETECTS AN UNDER-VOLTAGE CONDITION. 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO. , INC. 170 CHERRY AVE. , WEST SAYVILLE, N. Y. 11796 TEL: in NY 631-567-0314 TOLL FREE: 800-346-0857 FAX: 631-567-5826 INTRODUCTION: The 091-98-xx LOAD MANAGER 1H is a device, which continuously monitors the voltage of the battery. [. . . ] To decrease the voltage turn counter clockwise. Two indicator LED's are provided adjacent to the terminal strip. When the green LED is lit, the voltage sensed is normal. When the red LED is lit, the voltage is below the set point. The voltage detector can be tested by gradually lowering the system voltage while simultaneously measuring the voltage applied to the input terminals with a precise voltmeter and noting the voltage at which the red LED turns "ON". The 091-98-xx Load Manager 1H contains an adjustable high hysteresis feature. With the normal trip point set to 12. 0 volts (24. 00 volts), the hysteresis circuit maintains the relay energized until the voltage increases above 13. 45 volts. This assures that the loads being controlled are not energized until the sensed voltage reaches 13. 45 volts. This limits the ON/OFF cycling of the load. The hysteresis may be adjusted using trimmer R15. Turning R15 CCW will decrease the hysteresis while turning CW will increase. Unless absolutely necessary it is recommended that the hysteresis remain at the factory setting. SPECIFICATIONS: Model Input voltage Input amps, relay off Input amps, relay on Relay contacts, amps Case Weight 091-96-12 10 to 15 volts D. C. [. . . ] shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-96

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KUSSMAUL 091-96 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag