User manual LA CROSS TECHNOLOGY WS-1610TWC-IT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSS TECHNOLOGY WS-1610TWC-IT. We hope that this LA CROSS TECHNOLOGY WS-1610TWC-IT user guide will be useful to you.

Lastmanuals help download the user guide LA CROSS TECHNOLOGY WS-1610TWC-IT.


Mode d'emploi LA CROSS TECHNOLOGY WS-1610TWC-IT
Download
Manual abstract: user guide LA CROSS TECHNOLOGY WS-1610TWC-IT

Detailed instructions for use are in the User's Guide.

[. . . ] PROFESSIONAL WEATHER CENTER WS-1610TWC-IT Quick Set up Manual Quick Set Up Manual ­ Professional Weather Center Using 915MHz wireless transmission of weather data, this unique weather station can be powered using batteries for all your weather needs in the home or office. Carefully open and check that the following contents are complete: Item: Base Station Consisting of: 1) Main unit Fittings: Illustration: 1 ThermoHygro Sensor 1) Main unit 2) Rain protection cover 1) Wall mounting screws 2) Plastic anchors for screws 3) 2 x cable ties 1 x U-bolts for mast holder 2) 2 x Washers 3) 2 x Nuts 4) 2 x cable ties 1) Wind Sensor 1) Main unit with wind vane 2) 32ft cable (already attached the main unit) 3) Mast holder 1) Base and funnel 2) 32ft cable (already attached the main unit) Rain Sensor 1) 2 x Screws and Plastic anchors 2 Setting Up: Important: Operating power is supplied to both the wind and rain sensors by the thermo-hygro sensor Thermo-Hygro Sensor Weather center Sockets for wind and rain sensor Battery compartment Setting up using batteries: 1) Sensors: Pull and remove the protective rain cover of the Thermo-Hygro Sensor to reveal 2 socket ports and the battery cover. Insert the cables of the wind and rain sensors in the correctly marked sockets. Slide open the battery 3 2) compartment and checking the correct polarity insert 2 x AA IEC, LR6 1. 5V batteries and replace the cover and rain cover Base Station: Now open the battery cover at the back of the unit and checking the correct polarity insert 3 x AA IEC, LR6 1. 5V batteries and replace the battery cover Performing a function test and Setting time manually: 1. [. . . ] Remember to ensure that it locks into place before releasing. Thermo-hygro Sensor Rain Cover Main Unit Wall Bracket 50 An ideal mounting place for the Thermo-hygro sensor would be the outer wall beneath the extension of a roof, as this will protect the sensor from direct sunlight and other extreme weather conditions. To wall mount, use the 2 screws to affix the wall bracket to the desired wall, plug in the Thermo-hygro sensor to the bracket and secure both parts by the use of the supplied screw and ensure that the cables from the wind and rain sensors are correctly plugged in otherwise data transmission errors could occur. Wind Sensor Wind vane Vertical mast Wind fan Horizontal panel 51 Firstly, check that the wind-fan and the wind-vane can rotate freely before fixing the unit. For correct and accurate readings it is important to mount the sensor so that the front (marked E) is pointing in East-West direction. The wind sensor should now be mounted using the screw or cable tie provided onto a solid wall/ panel mast or mast to allow the wind to travel around the sensor unhindered from all directions (ideal mast 5 1 size should be from diameter about /8" to 1 /4"). Once the wind sensor is fixed onto the mast, connect the cable to the corresponding thermo-hygro sensor socket so that operating power supply can be received and data can be transmitted to the base station. Rain Sensor For best results, the rain sensor should be securely mounted onto a horizontal surface about 1 meter above the ground and in an open area away from trees or other coverings where rainfall may be reduced causing inaccurate readings. When securing into place, check that rain excess will not collect and store at the base of the unit but can flow out between the base and the mounting surface (test by pouring clean water). 52 After mounting the rain sensor, connect the cable to the thermo-hygro sensor at the corresponding socket so power supply can be received and data be transmitted to the base station The rain sensor is now operable. For testing purposes, very slowly pour a small amount of clean water into the rain sensor funnel. The water will act as rainfall and will be received and displayed at the base station after about 2 minutes delay i. e. when the reading interval is reached. CARE AND MAINTENANCE: · · · · · · Extreme temperatures, vibration and shock should be avoided as these may cause damage to the units and give inaccurate forecasts and readings. When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or scouring agents as they may mark the LCD and casings. Immediately remove all low powered batteries to avoid leakage and damage. Replace only with new batteries of the recommended type. Do make any repair attempts to the units. Return it to their original point of purchase for repair by a qualified engineer. Opening and tampering with the units may invalidate their guarantee. Do not expose the units to extreme and sudden temperature changes, this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy. 53 SPECIFICATIONS: Temperature measuring range: Outdoor : -40°F to +139. 8°F with 0. 2°F resolution -40ºC to +59. 9ºC with 0. 1ºC resolution ("OF. L" displayed if outside this range) Relative humidity measuring range: Outdoor : 1% to 99% with 1% resolution ("- -" displayed if < 1%, "99" displayed if 99%) Wind speed : 0 to 111. 8 mph (0 to 50 m/s) (displayed "OF. L" when > 50m/s) Wind chill : -40°F to +139. 8°F (-40ºC to +59. 9ºC) (displayed "OF. L" if outside this) Relative pressure pre-set range Rainfall Outdoor data reception Air pressure checking interval Transmission range Power: Weather Center Thermo-hygro sensor Battery life : : : : : : 27. 17 to 31. 90 inHg (919 to 1080 hPa) 0" to 393. 6" (0 to 9999 mm) (displayed "OF. L" when > 9999mm) every 4. 5 seconds every 15 seconds up to 330 feet (100meters) in open space : 3 x AA, IEC LR6, 1. 5V : 2 x AA, IEC LR6, 1. 5V approximately 24 months (Alkaline batteries recommended) 54 Dimensions (L x W x H) Weather Station Thermo-hygro transmitter Wind sensor Rain sensor : 6. 51" x 1. 21" x 5. 58" (165. 4 x 30. 8 x 141. 9 mm) : 2. 25" x 2. 44" x 6. 18" (57. 3 x 62 x 157 mm) : 9. 84" x 6. 45" x 7. 58" (250 x 164 x 192. 7 mm) : 5. 67" x 2. 15" x 3. 46" (144 x 54. 6 x 88 mm) LIABILITY DISCLAIMER · · · · · · · · · The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment. Please contact your local or/and regional authorities to retrieve the addresses of legal dumping grounds with selective collection. All electronic instruments must from now on be recycled. [. . . ] N'exposez pas les appareils à des changements extrêmes et soudain de température ; ceci peut provoquer des modifications rapides des prévisions et réduire ainsi leur précision. CARACTÉRISTIQUES TECHNIQUES : Plage de mesure de la température : Extérieure : -40°F à +140°F (résolution de 0, 2°F) -40ºC à +59, 9ºC (résolution de 0, 1ºC) ("OFL" affiché en dehors de cette plage) Plage de mesure de l'hygrométrie relative : Extérieure : 1% à 99% (résolution de 1%) ("- -" affiché si < 1%, "99" affiché si 99%) 113 Vitesse du vent Windchill Réglage de la Pression relative Pluviométrie Intervalle de réception de la données extérieures Intervalle de relève de la pression atmosphérique Rayon de transmission : : : : 0 à 111, 8 mph (0 à 50 m/s) (affiche "OFL" quand > 50m/s) -40°F à +140°F (-40ºC à +59, 9ºC) (affiche "OFL" en-dehors de ce rayon) 27, 17 à 31, 90 inHg (919 à 1080 hPa) 0" à 393, 6" (0 à 9999 mm) (affiche "OFL" quand > 9999mm) 4, 5 secondes 15 secondes jusqu'à 330 ft (100 m) en champ libre : : : Alimentation : Station Météo : 3 x AA, IEC LR6, 1, 5 V Transmetteur Thermo-Hygro : 2 x AA, IEC LR6, 1, 5 V Durée de vie des piles : environ 24 mois (Piles alcalines recommandées) Dimensions (L x P x H) Station Météo : 6. 51" x 1. 21" x 5. 58" (165. 4 x 30. 8 x 141. 9 mm) Transmetteur Thermo-Hygro : 2. 25" x 2. 44" x 6. 18" (57. 3 x 62 x 157 mm) Anémomètre : 9. 84" x 6. 45" x 7. 58" (250 x 164 x 192. 7 mm) Pluviomètre : 5. 67" x 2. 15" x 3. 46" (144 x 54. 6 x 88 mm) 114 INFORMATION DU CONSOMMATEUR : · · · · · · · · · · Les déchets des appareils électroniques peuvent contenir des substances dangereuses. Le rejet de ces déchets dans des décharges sauvages et/ou non contrôlées nuit fortement à l'environnement Consultez les services officiels locaux ou régionaux pour connaître les points de collecte sélective et de traitement les plus proches de chez vous Tous les appareils électroniques doivent être désormais recyclés. Chaque utilisateur doit contribuer activement au recyclage de ses propres déchets Le rejet sauvage des déchets électroniques peut avoir des conséquences sur la santé publique et sur la qualité de l'environnement Ainsi qu'il est indiqué sur la boîte et sur le présent produit, la lecture du manuel est recommandée pour une utilisation optimisée ; ce produit ne doit pas être jeté dans des poubelles non-spécialisées Le fabricant et ses fournisseurs déclinent toute responsabilité pour tous relevés incorrects et toutes conséquences pouvant découler de l'utilisation de relevés incorrects. Ce produit est conçu uniquement pour une utilisation domestique comme indicateur de températures et d'humidités. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSS TECHNOLOGY WS-1610TWC-IT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSS TECHNOLOGY WS-1610TWC-IT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag