User manual LA CROSS TECHNOLOGY WS-7017U-IT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSS TECHNOLOGY WS-7017U-IT. We hope that this LA CROSS TECHNOLOGY WS-7017U-IT user guide will be useful to you.

Lastmanuals help download the user guide LA CROSS TECHNOLOGY WS-7017U-IT.


Mode d'emploi LA CROSS TECHNOLOGY WS-7017U-IT
Download
Manual abstract: user guide LA CROSS TECHNOLOGY WS-7017U-IT

Detailed instructions for use are in the User's Guide.

[. . . ] FCC ID: OMOTX29U (transmitter) RF Exposure mobile: The internal / external antennas used for this mobile transmitter must provide a separation distance of at least 20 cm (8 inches) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 21: Modifications not expressly approved by this company could void the user's authority to operate the equipment. 105: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. [. . . ] From one floor of a building to another floor). In areas where the weather is not largely affected by the change of air pressure, the sensitivity setting should be set to 1. WEATHER ICONS There are 3 possible weather icons that will be displayed in the FORECAST LCD: Air pressure is increasing and the weather is expected to improve or remain good, an arrow pointing down indicates that the air pressure is decreasing and the weather is expected to become worse or remain poor. The comfort level indicator is located at the center of the INDOOR LCD. The indicator will display a happy face icon when the temperature is between 68°F and 79°F (20°C and 25. 9°C) , and the humidity is between 45% and 65%. A sad face icon will be displayed when the temperature and humidity are outside the mentioned ranges. When there is more than one remote temperature sensor unit in operation, a "boxed" number will appear to the right of the temperature. This indicates which remote temperature sensor unit (1, 2, or 3) is currently displaying its data in the OUTDOOR LCD. MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-7017U-IT keeps a record of the MINIMUM and MAXIMUM temperature, and the time and date of their occurrence-for both the indoor and outdoor modes. "MIN" appears above the indoor temperature and the LCD will flash, indicating that the minimum temperature and humidity, and the time and date of occurrence of the indoor temperature are displayed. The minimum records will display for 30 seconds before returning to the normal display mode. While "MAX" is still displayed press the IN button again to return to the current data display. Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will automatically return to current data readings. "MIN" appears above the outdoor temperature and the LCD will flash, indicating that the minimum temperature, and the time and date of occurrence are displayed. The minimum records will display for 30 seconds before returning to the normal display mode. Press the OUT button again (once while "MIN" is still displayed, twice otherwise). "MAX" appears above the outdoor temperature and the LCD will flash, indicating that the maximum temperature and the time and date of occurrence are displayed. Press and release the SET button to confirm the forecast sensitivity and complete the programming. Sunny-indicates that the weather is expected to improve (not that the weather will be sunny). Sun with Clouds-indicates that the weather is expected to be fair (not that the weather will be sunny with clouds). Clouds with Rain-indicates that the weather is expected to get worse (not that the weather will be rainy). [. . . ] Screw mounting bracket onto the mounting surface. Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and casings. Immediately remove all low powered batteries to avoid leakage and damage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSS TECHNOLOGY WS-7017U-IT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSS TECHNOLOGY WS-7017U-IT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag