User manual LA CROSSE TECHNOLOGY WS2350

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS2350. We hope that this LA CROSSE TECHNOLOGY WS2350 user guide will be useful to you.

Lastmanuals help download the user guide LA CROSSE TECHNOLOGY WS2350.


Mode d'emploi LA CROSSE TECHNOLOGY WS2350
Download
Manual abstract: user guide LA CROSSE TECHNOLOGY WS2350

Detailed instructions for use are in the User's Guide.

[. . . ] Operation Manual Professional Remote Weather Station Table of Contents Page 1. 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Weather Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 15°C and a relative humidity of 50% the dewpoint will be about 5°C, at 80% humidity about 12°C. At a relative humidity of 100% saturation is reached, i. e. At a dewpoint below freezing the fallout will become frost or snow. Windchill has been introduced for battle planning during World War II. It represents not the real measured but the one temperature a person feels in open area under the influence of wind and cold. Windchill is laid out in tables for various temperatures and wind speeds. 8°C and calm winds a person moving at a speed of 6 m/s will already feel a windchill temperature of 0°C. Wind Data (LCD Section 3) The current wind direction will be displayed on the LCD compass on the wind section. Press the WIND key to toggle between wind direction as numerical (e. g. 225°) and abbreviated characters (e. g. SW) as well as numerical wind speed display inside the compass circle. 69 12. Operation keys The base station has 8 keys for easy operation. Please refer to the following table for use and function of each key: Further descriptions of the key functions with regard to their immediate range of application can be found in the Programming modes: SET - key - In normal mode to enter the manual basic programming mode - In basic programming mode to select the following setting modes: - LCD contrast setting - Manual time setting (hours/minutes) - 12/24 time format display - Calendar setting (year/month/date) - Time zone setting - °C/°F temperature setting - Wind speed unit setting - Rainfall unit setting - Pressure unit setting - Relative air pressure setting - Weather picture threshold setting - Storm warning setting - Acoustic storm alarm setting - In setting modes confirmation of the selected values - In alarm modes alarm ON/OFF - In alarm mode to enter programming of alarm values (long pressing) - To exit MIN/MAX modes - Toggle between Absolute and Relative air pressure displays - Toggle between the following current/ maximum/ minimum display modes: - Indoor temperature and humidity - Outdoor temperature and humidity - Outdoor wind chill - Outdoor dew point - Rainfall (24h, 1h, total) To toggle between the following settings: 70 PRESSURE key DISPLAY - key WIND - key ALARM - key - MIN/MAX - key PLUS(+) ­ key - MINUS(-) ­ key - Wind speed Wind direction Wind direction display in degrees In normal mode to enter the alarm programming mode In alarm programming mode to select the following setting modes: Time alarm setting Indoor temperature alarm (high & low) Outdoor temperature alarm (high & low) Indoor humidity alarm (high & low) Outdoor humidity alarm (high & low) Outdoor wind chill alarm (high & low) Outdoor dew point alarm (high & low) Rainfall alarm (24h, 1h) Pressure alarm (high & low) Wind speed alarm (high & low) Wind direction alarm In setting modes confirmation of the selected values To exit MIN/MAX modes To reset general alarm symbol In normal display mode to toggle between display of MIN/MAX values To toggle between MIN/MAX values in MIN/MAX mode To exit any programming mode In normal display mode to toggle between format of date display, seconds, time alarm and time zone To increase the values in the setting modes To exit MIN/MAX modes In normal display mode to re-enter data learning mode (long pressing for 2 seconds) In normal display mode to enable/disable the buzzer alarm (long pressing) To decrease the values in the setting modes In basic programming mode acoustic storm alarm ON/OFF 71 - To turn the alarms off 24 hours when the alarm is sounding - In MIN/MAX modes to resets recorded values and recorded dates and times * Press any key to activate the LCD Backlight 13. Basic Programming Modes Manual Setting modes The manual setting mode allows the user to change several basic settings, which is done by accessing one mode after the other simply by pressing the SET key. After the final mode, or if no key is pressed for 30 seconds, the manual setting returns to the normal display mode. The manual setting takes the user through the following modes: 1. 8 level LCD contrast setting (default level 5) 2. 12/24h time display select (default 24 hours) 4. Time zone setting ±12 hours (default 0) 6. Temperature display unit degree Celsius or Fahrenheit (default degree Celsius) 7. Wind speed display units in m/s, km/h, mph, Beaufort, knots (default setting km/h) 8. Rainfall display in mm or inch (default setting mm) 9. Air pressure display in hPa or inHg (default setting hPa) 10. [. . . ] Poorly shielded PCs can cause interferences that will reduce or in some cases stop reception Cleaning and Maintenance Clean the housing and screen of the base station only with a soft damp cloth. Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for blockages every now and then. Also clean the seesaw of the sensor with a damp cloth and - - 21. - 87 - - check by lightly tapping with your finger that it can move freely from side to side. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS2350

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS2350 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag