User manual LEICA TCS STED CW BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LEICA TCS STED CW. We hope that this LEICA TCS STED CW user guide will be useful to you.

Lastmanuals help download the user guide LEICA TCS STED CW.


Mode d'emploi LEICA TCS STED CW
Download
Manual abstract: user guide LEICA TCS STED CWBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Leica TCS STED CW The Fast Track to Superresolution · Freedom to choose ­ popular fluorescent dyes and proteins · Observe what´s inside ­ with confocal superresolution · Nanoscale imaging ­ devoid of mathematical artifacts · Upgrading, to STED ­ quick and affordable · Watch live cell dynamics ­ at the nanoscale! 2 Superresolution light microscopy is revolutionizing life science research with increasing speed. The charm of direct visual results from an intact specimen on the nanometer scale attracts scientists from all fields of biomedical research. In its early days, superresolution was only for biophysicists and optical specialists. Nowadays, it has become an indispensable method in many life science research institutes working with light microscopes. [. . . ] This reduces the effort of fluorescence labeling and offers the most direct way for live cell imaging. By offering excitation lines such as 488 nm and 514 nm in combination with the depletion line at 592 nm, proteins such as eYFP and Citrin can be imaged with the Leica TCS STED CW. This enables researchers to record in order to follow structural changes on the nanoscale ­ live!Standard fluorophores ­ for fixed and living cell investigations All researchers are attracted by the potential of superresolution microscopy. Still, they want to rely on their well proven standard procedures and labeling strategies. 8 Living Cell Imaging using Fluorescent Proteins Vesicle movement Confocal STED 3 m 3 m Confocal STED STED t = 0 sec 1 m t = 0 sec 1 m t = 18 sec STED STED STED t = 36 sec t = 54 sec t = 72 sec Time lapse experiment: movement of large dense core vesicles labeled with the fluorescent protein Venus inside of living PC12 cells. 9 Observe What's Inside ­ with Confocal Superresolution STED CW Features · Flexible STED-excitation: Ar Laser (488 & 514 nm) STED: Fiber laser 592 nm; intensity modulated by AOTF · XY-resolution (FWHM) < 80 nm (measured on Chromeo 488 nano-beads), depending on sample, embedding and staining · Integrated linear deconvolution · Z-resolution: confocal · Auto beam alignment of excitation and STED beam for long term stability · Vortex phase filter for maximum resolution · Available in combination with AOBS and dichroic systems · Simultaneous line sequential recording of STED and confocal possible · Recording speeds of > 20 frames per seconds with < 80 nm lateral resolution · Full range of SP5 features supported, exclusive 405/UV Life is three-dimensional ­ and many important events which scientists are interested in happen under the surface. Thus, there is no chance to get insights with imaging technologies which are limited to the area in direct contact with the coverslip. The superior optical sectioning of the true point scanning system TCS SP5 provides superresolution where you need it: deep in the sample. STED images of a 12 m thick drosophila larvae featuring a thick cuticula ­ no problem. This is the edge of confocal superresolution! Purely Optical The well-known saying "seeing is believing" expresses it best: The success story of light microscopy is directly connected to its direct delivery of information to the researcher about the investigated specimen. Breaking the diffraction resolution barrier by STED is the logical consequence of this very fact. STED is based on a well-thought-out interplay of fine optics and well understood photophysical processes of the fluorophore. And it is currently the method to achieve superresolution in a purely optical way. The Leica TCS STED CW microscope delivers superresolution pixel by pixel ­ independent of recording speed or the dye being used. Plenty of time can be saved since time-consuming data processing steps and complex algorithms are obsolete. STED microscopy requires one single frame to generate one superresolution image ­ in contrast to other localization or interference based concepts. This makes STED extremely robust against interframe-drifts and facilitates data handling due to their size. In addition, the experienced user can improve his data by applying image deconvolution on top of the STED recording. The processing steps are uncomplicated and the workflow is embedded into the Leica confocal software LAS AF. As in the TCS STED with pulsed laser beams, spatial overlay accuracy of excitation laser and STED "doughnut" remains crucial to get the best results. This is granted by the patented and software controlled alignment routine which adjusts the laser beams automatically, activated by a single mouse click and completed within a minute. The entire calibration routine takes place inside the scanner chassis, not on the sample being investigated. The specimen is not illuminated during that process and the experiments can be continued immediately afterwards, since all recording parameters are restored. [. . . ] Avalanche Photodetectors Avalanche Photodetectors (APDs) are established tools for single molecule detection methods like fluorescence correlation spectroscopy (FCS) because of their substantially higher quantum efficiency compared to conventional internal photodetectors. This increase in sensitivity makes them a good choice when working with weakly fluorescent samples and the ideal complement for STED microscopy. Particularly for CW STED it is possible to achieve a significant resolution increase, depending on sample and recording settings. Leica TCS SP5 Features · Precise optical sectioning with SuperZ Galvo stage · Femtosecond and picosecond IR lasers · Up to 64 Megapixels/image, field rotation 200°, also for resonant scan · Maximum transmission with prism-based Leica SP detector · 5 spectral confocal channels (max) · Extreme sensitivity with Leica AOBS® 8 non-descanned channels (max)* · APD (Avalanche Photo Diode) detection for ultimate sensitivity* · Very fast beam path configuration · Most effective channel separation *optional Tandem Scanner. By means of a motorized and computer controlled high precision device, a conventional and a resonant gavanometrically driven scan mirror are moved into the proper position for scanning, while the scan-electronics are switched simultaneously. 17 Configure Your STED System ­ According to Your Science! Applications/technical features AOBS Resonant scanner APD 5 PMT IR laser Transmitted & reflected light detectors · · Live cell imaging · · · Various fluorophores · · · · · · · · · Multiphoton imaging Multiple users · Deep tissue imaging · Figure legends: Page 2-3 (from left to right) 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEICA TCS STED CW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LEICA TCS STED CW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag