User manual LG ARNU09GCEA2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG ARNU09GCEA2. We hope that this LG ARNU09GCEA2 user guide will be useful to you.

Lastmanuals help download the user guide LG ARNU09GCEA2.


Mode d'emploi LG ARNU09GCEA2
Download

You may also download the following manuals related to this product:

   LG ARNU09GCEA2 (4497 ko)
   LG ARNU09GCEA2 (763 ko)

Manual abstract: user guide LG ARNU09GCEA2

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH PORTUGUESE §§¡ LG Indoor Unit (2 Series) Type: Floor Standing Concealed Floor Standing OPERATING TEMPERATURE(°C) COOLING MODE INDOOR OUTDOOR MAX. 32°C 21°C 43°C 21°C HEATING MODE INDOOR OUTDOOR MAX. 27°C 20°C 24°C 1°C DUTCH IMPORTANT · Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. · Please retain this owner's manual for future reference after reading it thoroughly. êìëëäàâ üáõä Floor Standing Concealed Floor Standing Type Indoor Unit Owner's Manual TABLE OF CONTENTS FOR YOUR RECORDS Safety Precautions. . . . . . . . . . . . . . . . . 3 Prior to Operation . . . . . . . . . . . . . . . . . . 6 Operating Instructions. . . . . . . . . . . 7 Name and Function of Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Maintenance and Service . . . . . . 9 Before you Call for Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. [. . . ] Take care to ensure that nobody could step on or fall onto the outdoor unit. · This could result in personal injury and product damage. 4 Indoor Unit Safety Precautions I Installation Always check for gas (refrigerant) leakage after installation or repair of product. · Low refrigerant levels may cause failure of product. Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. · It may cause a problem for your neighbors. CAUTION Install the drain hose to ensure that water is drained away properly. · A bad connection may cause water leakage. Use two or more people to lift and transport the product. Keep level even when installing the product. · To avoid vibration or water leakage. Do not install the product where it will be exposed to sea wind (salt spray) directly. · It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation. Do not block the inlet or outlet of air flow. ENGLISH I Operation Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft. ) Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. · There is risk of damage or loss of property. Do not touch the metal parts of the product when removing the air filter. · There is risk of personal injury. · This could harm to your health. · It may cause product failure. Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. · There is risk of fire, electric shock, or damage to the plastic parts of the product. Clean the filter every two weeks or more often if necessary. · A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. [. . . ] When the air conditioner is to be used again. I Check that the air inlet and outlet of the indoor/outdoor unit are not blocked. Turn off the circuit breaker. CAUTION CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. Helpful information The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted. Operation Tips Do not overcool the room. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ARNU09GCEA2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG ARNU09GCEA2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag