[. . . ] Visit us at http://www. lgservice. com LG LG Multi Air Conditioner OWNER'S MANUAL Dear Owner Thank you for installing LG air conditioner. Your best choice guarantees you a great performance and service to make your life comfortable & pleasant. IMPORTANT · Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. · Please retain this owner's manual for future reference after reading it thoroughly. P/No. : MFL37562506 Room Air Conditioner Owner's Manual TABLE OF CONTENTS A. Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 B. [. . . ] If the system is not operating as desired, switch manually to another mode. To run the auto operation follow steps 1, and 2. (See operation mode) Auto Auto Clean (Optional) During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed. AUTO CLEAN NOTE 1. Press the AUTO CLEAN BUTTON to activate this function. Now whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. This dries up any remains of moisture & cleans the unit internally. If you press AUTO CLEAN BUTTON again during operation, this function is cancelled. During auto clean function, only START/STOP BUTTON and AUTO CLEAN BUTTON can be used. Owner's Manual 13 Operating Instructions Jet Cool/Heat Operation Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling. Similarly, jet heat function (available only in some models) warms up the room quickly by operating at super high fan speed and 30°C setting temperature for 60 minutes. You can activate this operation by pressing the JET COOL BUTTON. To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again. NOTE · Jet cool function cannot be activated during heating or auto changeover operations. · In case of Inverter, Art Cool and Art Cool Wide(non-Deluxe) model, you can use jet heat function by pressing JET COOL BUTTON for heating operation. · Art Cool and Art Cool Wide models close the side discharges during jet cool/heat operation, for strong cooling and heating. Display Luminosity (Optional) -Art Cool Mirror Type AUTO CLEAN · The Display Luminosity of the unit can be adjusted by using the Remote Controller. Press the start/stop button to start the unit. Open the door on the Remote Controller, press the 2nd F button and, press display luminosity button. Press the button again to set bright display. PLASMA Purification Operation (Optional) Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons. This plasma kills and destroys the contaminants completely to provide clean and hygienic air. Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller. Repressing it will deactivate the operation. NOTE This feature can be used in any operation mode and any fan speed can be used while plasma filter is functioning. 14 Room Air Conditioner Operating Instructions Forced operation Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button. ON/OFF button On/Off On/Off button button Cooling Model Operating mode Indoor FAN Speed Setting Temperature Cooling High 22°C Room Temp. 24°C Cooling High 22°C Heat pump Model 21°C Room Temp. < 24°C Healthy Dehumidification High 23°C Room Temp. < 21°C Heating High 24°C Test operation During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. [. . . ] If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room. This is not good for the health and wastes electricity. Keep blinds or curtains closed. Do not let direct sunshine enter the room when the air conditioner is in operation. Keep the room temperature uniform. Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room. Make sure that the doors and windows are shut thight. Avoid opening doors and windows as much as possible to keep the cool air in the room. Clean the air filter regularly. Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks. Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and ten. Use high fan speed for effective and fast cooling. The unit gives its rated cooling capacity when the fan speed is high. Self-Diagnosis Function This unit has an inbuilt error diagnosis capability. Unit LED( Please contact your serviceman/dealer in such a situation Error Display LED ( (once) ) ) will blink in case if thermistor fails. Check Point · Indoor room temperature thermistor open/short. · Indoor pipe temperature thermistor open/short. 3 sec 3 sec 3 sec Owner's Manual 21 Maintenance and Service Troubleshooting Tips! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG LMNH126D4L0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG LMNH126D4L0 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag