User manual LG PQRCVCL0QW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG PQRCVCL0QW. We hope that this LG PQRCVCL0QW user guide will be useful to you.

Lastmanuals help download the user guide LG PQRCVCL0QW.


Mode d'emploi LG PQRCVCL0QW
Download
Manual abstract: user guide LG PQRCVCL0QW

Detailed instructions for use are in the User's Guide.

[. . . ] ENGLISH ITALIANO ESPAÑOL FRANCAIS DEUTSCH PORTUGUESE êìëëäàâ üáõä OWNER’S & INSTALLATION MANUAL SIMPLE WIRED REMOTE CONTROLLER Please read this manual carefully before operating your set and retain it for future reference. Models : PQRCVCL0Q PQRCVCL0QW P/NO : MFL62862002 www. lg. com Simple Wired Remote Controller Ownerʼs & Installation Manual TABLE OF CONTENTS n Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 n Part Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Simple Wired Remote Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 n Installation Instruction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5~6 Group control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installer setting – How to enter installer setting mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installer setting – Test Run Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installer setting – Setting Address of Central Control . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installer setting – E. S. P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Installer setting – Thermistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installer setting – Ceiling Height Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Installer setting – Static Pressure Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Installer setting – Remote Controller Master/Slave Setup. . . . . . . . . . . . . . . . . . . . 15 Installer setting – Celsius/Fahrenheit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 n Owners instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Standard Operation – Cooling Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Standard Operation – Heating Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Standard Operation – Auto Operation Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Standard Operation – Dehumidification Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Standard Operation – Fan Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Function Setting – Fan Speed Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Function Setting – Room temperature check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Function Setting – Child Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Function Setting – Auto Swing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Function Setting – Vane Angle Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Different mode drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Checkups before reporting breakdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 2 Wired Remote Controller Safety Precaution ENGLISH Safety Precaution • The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company. • For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service. • The following safety cautions are provided to prevent unexpected dangers or losses. WARNING : If the user does not follow the mandatory items, it may result in serious injury or death. CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property damage. [. . . ] - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. OPER MODE • As the characteristic of the ʻ2THʼ function can be different in accordance with the products, refer to the product instruction manual for its detail. 12 Wired Remote Controller Installation instruction ENGLISH Installer Setting -Ceiling Height Selection This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product) button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the button. * Ceiling height setting code value : 05 OPER MODE 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE Code value Value *Setting value 01: Low 02: Standard 03: High 04: Very high currently 3 When pressing the heightbutton, will be established ceiling value set up. button 4 When pressing the for moreand 3 button simultaneously than OPER MODE • As the ceiling height setting standard can be different in accordance with the products, refer to the product instruction manual for its detail. seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. <Ceiling Height Selection Table> 01 02 03 04 Ceiling Height Level Low Standard High Very high Description Decrease the indoor airflow rate 1 step from standard level Set the indoor airflow rate as standard level Increase indoor airflow rate 1 step from standard level Increase indoor airflow rate 2 steps from standard level • Ceiling height setting is available only for some products. • Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit. • Refer to the product manual for more details. Ownerʼs & Installation Manual 13 Installation instruction Installer Setting -Static Pressure Setting This function is applied to only duct type. Setting this in other cases will cause malfunction. button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the oper-mode button. * Static pressure setting code value : 06 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE Code value Value *Setting value 01:V-H 02:F-H 03:V-L 04:F-L button, currently 3 When pressing pressure value will be established static set up. button 4 When pressing the for moreand 3 button simultaneously than OPER MODE seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. <Static Pressure Setting Table> Pressure selection 01 02 03 04 V-H F-H V-L F-L Function Zone state Variable Fixed Variable Fixed ESP standard value High High Low Low 14 Wired Remote Controller Installation instruction ENGLISH Installer Setting-Remote Controller Master/Slave Setup It is a function for settings in group control, or 2-remote controller control. button 1 When pressing the for moreand 3 button simultaneously than OPER MODE seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the oper-mode button. * Remote controller master/slave setting code value : 07 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE *Setting value 00:Slave 01:Master Code value Value button, currently 3 When pressing thepressure value will be established static set up. 4 When pressing the forbutton and 3 button simultaneously more than OPER MODE seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. Remote controller Master Slave Function Indoor unit operates based on master remote controller at group control. (Master is set when delivering from the warehouse. ) Setup all remote controllers except one master remote controller to slave at group control h Refer to the 'group control' part for details • When controlling in groups, basic operation settings, airflow strength weak/medium/strong, lock setting of the remote controller, time settings, and other functions may be restricted. Ownerʼs & Installation Manual 15 Installation instruction Installer Setting-Celsius / Fahrenheit Switching This function is used for switching the display between Celsius and Fahrenheit. (Optimized only for U. S. A) 1 When pressing the button and button simultaneously for more than 3 seconds, the system will be entered into the installer setting mode. - After entering into the installer setting mode, select the ceiling height setting code value by pressing the oper-mode button. * Celsius/Fahrenheit setting code value : 07 OPER MODE 2 Select the desired setting value with the temperature up(▲), down(▼) button. FAN SPEED TEMP OPER MODE *Setting value 00:Celsius 01:Fahrenheit Code value Value 3 When pressing button, currently established celsius/Fahrenheit setting value will be set up. 4 When pressing the button and button simultaneously for more than 3 seconds after the setting has been completed, the setting mode will be released. - If there isn’t any button input for more than 25 seconds, the installer setting mode will also be released. OPER MODE • Whenever press temp up(s), down(t) button in Fahrenheit mode, the temperature will increase/drop 2 degrees. 16 Wired Remote Controller Owner's instruction ENGLISH Owner's instruction Standard Operation - Cooling Mode It cools the room by comfortable and clean wind. operation 1 Cooling button. will begin if you press the set the 2 Press the temperature button andthan the desired room temperature lower current room temperature. A click of the button will increase the desired temperature by 1°C or 2°F. [. . . ] 60 seconds after the setting, the system will be coming out of the vane angle control setting mode automatically. OPER MODE * Vane number and the angle of wind can be selected differently in accordance with the products. 26 Wired Remote Controller Owner's instruction ENGLISH Different mode drive Different mode drive is a phenomenon taking place when indoor units' drive mode is different in the case that a few indoor units are set up at one AHU. (Different mode drive doesn't show up at cooling exclusive model. ) heating 1 If one indoor unit operateoperating mode while several indoor units are cooling mode, outdoor segment and cooling segment are blinking like display on the left. => It means operation of cooling mode in outdoor unit. operate cooling or 2 If one indoor unitmode while several indoor dehumidification units are operating heating mode, outdoor segment and cooling segment are blinking. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG PQRCVCL0QW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG PQRCVCL0QW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag