User manual LIFT-MASTER 1145C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER 1145C. We hope that this LIFT-MASTER 1145C user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER 1145C.


Mode d'emploi LIFT-MASTER 1145C
Download
Manual abstract: user guide LIFT-MASTER 1145C

Detailed instructions for use are in the User's Guide.

[. . . ] Unit 11, 230 Bayview Drive Barrie, Ontario L4N 5E9 Owner's Manual Garage Door Opener (1100 Series -- Canada) FOR RESIDENTIAL USE ONLY CAUTION!PLEASE READ THIS MANUAL CAREFULLY The MODEL NUMBER label is located on the front panel of your opener CONTENTS PAGE CONTENTS PAGE Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features of Your Opener. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Door will OPEN from Door Control Button, Key Switch and Keyless Entry Systems. Door will CLOSE if door control button is pressed and held until the door closes fully. If button is released before down travel is completed, door will reverse. TO TURN OFF: Press Lock Switch button again. Normal operation will LIGHT SWITCH TO ACTIVATE: Press Light Switch button. Opener light will turn on (or remain on if opener is still in 41/2 minute automatic cycle). TO TURN OFF: Press Light Switch button again. WIRING INSTRUCTIONS FOR ACCESSORIES NOTE: To turn light OFF during 4-1/2 minute automatic cycle, press Light Switch button twice · to activate and then to turn off Light Switch Feature. The Protector SystemTM To white and black opener terminals Outdoor Key Switch: To red and white opener terminals INSTALL THE LIGHTS Install a 75 Watt maximum light bulb in each socket. Lights will turn ON and remain lit for 4-1/2 minutes when power is connected. If bulbs burn out prematurely due to vibration, replace with "Garage Door Opener" bulbs. INSTALL THE LENSES Slide lens into guides as shown. For convenience, lenses may be installed after Adjustment Step 3, Page 22. 15 INSTALLATION STEP 6 Attach Manual Release Rope & Handle USE MANUAL RELEASE ROPE ONLY TO DISENGAGE TROLLEY. DO NOT USE ROPE AND HANDLE TO PULL DOOR OPEN OR CLOSED. PROCEDURE: Thread one end of rope through hole in top of red handle so 'NOTICE' reads right side up as shown. NOTE: Knot should be at least 1" from the end of the rope to prevent slipping. Thread other end of rope through hole in release arm of outer trolley. Adjust rope length so that handle is 6 feet above the floor. NOTE: If it is necessary to cut rope, heat seal cut end with a match or lighter to prevent fraying and/or raveling. INSTALLATION STEP 7 Connect Electric Power Opener MUST be permanently wired or plugged into a grounded 3-prong receptacle wired according to local electrical codes. DO NOT USE an extension cord. TO AVOID SERIOUS PERSONAL INJURY FROM ENTANGLEMENT, REMOVE ALL THE ROPES CONNECTED TO GARAGE DOOR BEFORE OPERATING OPENER. TO AVOID DAMAGE TO GARAGE DOOR AND OPENER, MAKE DOOR LOCKS INOPERATIVE BEFORE CONNECTING ELECTRIC POWER. USE A WOOD SCREW OR NAIL TO HOLD LOCKS IN "OPEN" /UNLOCKED) POSITION. THE INSTALLATION & THE WIRING MUST BE IN COMPLIANCE WITH LOCAL ELECTRICAL AND BUILDING CODES. OPERATION AT OTHER THAN 120V 60Hz WILL CAUSE OPENER MALFUNCTION AND DAMAGE. RIGHT WRONG PROCEDURE FOR PERMANENT WIRING (if required by local codes) DISCONNECT THE POWER AT THE FUSE BOX BEFORE PROCEEDING. Refer to illustration. [. . . ] and RPM sensor) Cover (Specify model) Helical gear & retainer w/grease Limit switch assembly RPM sensor assembly Wire harness assy. w/plug Shaft bearing kit Interrupter cup assy. (Model 1145) (Models 1160 and 1150) Complete with: Logic board End panel w/all labels End panel w/all labels (Model 1145) End panel w/all labels (1160 and 1150) NOT SHOWN Chassis assy. hardware kit (includes screws not designated by a number in illustration) 3 4 5 6 7 8 9 41A2817 41B2991-1 143D100 41A2916 175B88 108D36 108D34 30B363 30B387 12A373 12 13 14 15 16 17 18 19 51R370 41A2818 41D3452 41C3005 41C2726 41A2826 41A2822 41A3627 41A3626 20 41A3712 41A3673 41A2825 27 LIFT-MASTER SERVICE IS ON CALL OUR LARGE SERVICE Organization SPANS THE UNITED STATES AND CANADA HOW TO ORDER REPAIR PARTS Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SIX DAYS A WEEK. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 1145C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 1145C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag