User manual LIFT-MASTER 90 T1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER 90 T1. We hope that this LIFT-MASTER 90 T1 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER 90 T1.


Mode d'emploi LIFT-MASTER 90 T1
Download
Manual abstract: user guide LIFT-MASTER 90 T1

Detailed instructions for use are in the User's Guide.

[. . . ] If the power rating of such device exceeds the contact rating, use a relay for interfacing. A timer defeat switch may be used to disable the timer when it is not required. PACKING LIST: PART NUMBER 24-24-6 26-200-1 27-10199 40-10222 42-104 84-ST-06 82-PX-06-06t 82-PX06-19 82-PX08-10T 84-LN-06 85-FW-06 95-OR08-68 95-BK13-69 95-RD13-69 95-YE13-69 95-BL13-19 95-BR03-66 95-RD12-68 95-RD24-88 95-GY12-68 95-BR14-66 95-YE27-46 76-29V30500 84-FN-08 95-BR27-9G Timer Kit DESCRIPTION RELAY, 24VAC, 3PDT TIMER, DUAL FUNCTION 24V TY WRAPS LABEL FOR TERMINAL BLOCK 4 POSITION TERMINAL BLOCK TINNERMAN NUT #6-32 X 3/8" SELF TAP SCREW #6-32 X 1-3/8" PH SCREW #8-32 X 5/8" PHILLIPS SELF TAP SCREW #6-32 LOCKNUT #6 FLATWASHER WIRE 8" ORANGE . 250 SPADE X . 187 FASTON (INSULATED) WIRE, 13" BLACK, 1/4" INSULATED FASTON x . 250 SPADE WIRE, 13" RED, 1/4" INSULATED FASTON x . 250 SPADE WIRE, 13" YELLOW, 1/4" INSULATED FASTON x . 250 SPADE WIRE, 13" BLUE, STRIP x 1/4" INSULATED FASTON WIRE, 3" BROWN . 250 FORK x . 250 FORK WIRE, 12" RED . 187 FASTON x . 250 FORK (INSULATED FASTON) WIRE, 24" RED . 187 FASTON x . 187 FASTON (INSULATED) WIRE, 12" GREY . 187 FASTON x . 250 FORK (INSULATED FASTON) WIRE, 14" BROWN . 250 FORK x . 250 FORK WIRE, 27" YELLOW . 250 FASTON x . 250 FORK MOV ASSEMBLY FOR USE WITH TIMER KIT #8-32 SERRATED FLANGE NUT WIRE 27" BROWN . 250 FASTON (INS) X . 250 DOUBLE FASTON QUANTITY 1 1 16 1 2 2 1 1 2 1 2 1 2 1 1 1 1 1 1 1 1 1 1 2 1 INSTALLATION INSTRUCTIONS NOTE: Before you start modification, test all operator functions, then disconnect power. 1. COMPONENT MOUNTING Familiarize yourself with the component layout in the electrical box of the operator and the new parts included with this kit. [. . . ] Determine which limit switch is the open auxiliary switch and remove all three wires (yellow, orange and purple) from the switch and the terminals they are attached to, discard wires. From the new R1 relay remove the red wire (that goes from coil of the relay to the R3 terminal on 3 position radio block) from the coil of the relay and install on common of the auxiliary open limit switch. From the new R1 relay install a new 24" red wire from the coil to the normally closed on the auxiliary open limit switch. From the new R1 relay remove red wire from coil that goes to terminal #1 and discard wire. From the new R1 relay connect new 12" red wire from coil to terminal #11. Move the grey wire from terminal #1 to terminal #11. Move the orange wire from terminal #7 to terminal #1. On timer locate the brown & orange double connected wire. Install the orange wire on third common on new R1 relay. Install the brown wire on R1 of the 3 position radio block. Install the 12" grey wire to the normally open on the new R1 relay that corresponds to the orange wire in step (i) and connect to terminal #11. Install the 3" brown jumper wire between terminals #11 and #12 (if timer defeat switch is going to be used put switch in place of brown jumper wire). Install the 13" blue wire from the #3 on the timer to the orange wire nut. Install the 13" yellow wire from #5 on the timer to terminal #12. Install the 13" red wire from #1 on the timer to terminal #2. Install the 13" black wire from #6 on the timer to terminal #14. Install the 13" black wire from #7 on the timer to terminal #13. Locate MOV (Metal Oxide Varsitor #76-29V30500) this looks like two orange wires with black heat shrink tubing and install from A1 to A2 on the open contactor coil (see figure on pg. For "T1" type wiring install the 14" brown jumper between terminals #1 an #11. Refer to control wiring features on back page to determine desired wiring type. To utilize radio receiver block (R1, R2 and R3): a. If open and a start timer is not desired move the yellow wire from terminal #7 to terminal #1. [. . . ] CONTROL FEATURES NOTES: CONTROL FEATURES OPEN control (1) requiring only momentary contact WIRING TYPE T1 T2 CLOSE button requiring only momentary contact 1. OPEN control may be any number of the following devices wired in parallel: push-button, key switch, pull switch, card reader, digital key, vehicle loop detector, photo beam, telephone entry control, or other similar device. SAFETY device may be any number of the following devices wired in parallel: pneumatic door edge, electric door edge, photo beam, motion detector, or other similar device. Audible/visible Warning device may be light, strobe, horn, buzzer, or other simular device. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 90 T1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 90 T1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag