User manual LIFT-MASTER BG3000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER BG3000. We hope that this LIFT-MASTER BG3000 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER BG3000.


Mode d'emploi LIFT-MASTER BG3000
Download
Manual abstract: user guide LIFT-MASTER BG3000

Detailed instructions for use are in the User's Guide.

[. . . ] ESTATE SERIES B3 MODEL BG 3000-B3 INSTALLATION MANUAL HEAVY DUTY, HIGH CYCLE, INDUSTRIAL BARRIER GATE OPERATOR MODEL BG 3000-B3 IS FOR VEHICULAR PASSAGE GATES ONLY, NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE 3 YEAR WARRANTY Serial # _____________________ (located on electrical box) Installation Date ______________ TABLE OF CONTENTS SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 BASIC INSTALLATION HINTS AND RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PART 1 SITE PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOCATION AND LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Doc 01-20206 (6001521) 14 of 36 M. POST INSTALLATION PROCEDURES 1. Turn on the main power at the gate operator's circuit breaker. Verify that switch S2 (the Gate Open Direction switch) is set to the correct position. Verify that Manual Open fully opens the gate and that the open limit switch stops the gate. Verify that Manual Close fully closes the gate and that the close limit switch stops the gate. Note: If the gate stops due to a Obstruction Fault, readjust the gate sensitivity pots. Mechanical Use the Manual Input commands to verify that: 1. The gate swings open and closed smoothly. There is no squeak or vibration in the gate when it is moving . There is no belt slippage when the gate moves or stops. Both gates open and close at the same time (Bi-Parting gates only). Left/Right Obstruction sensitivity: Apply a bump to the opening and closing gate and verify that the gate reverses. Start-up (Gate response time) : Apply a bump to the gate as it initiates opening and closing and verify that the gate responds to the bump within a second. Activate the CYCLE input (entry system), RADIO input (radio transmitter), and EXIT Loop input (driving over the exit loop) and verify that they fully open the gate. If Reclose Timer is ON, it will close the gate. Activate the FIRE input (fire department switch) and verify that the gate fully opens and then closes immediately. If Reclose Timer is ON, it will close the gate. If you want the CYCLE input (Entry system) or RADIO input (Transmitter) to both open and close the gate, on switch S1 set TIMER to OFF and ATG to OFF. Activate the CYCLE command, wait until the gate is fully open, then activate the CYCLE command again. The gate should close, verifying Alternate Action operation. Note: If you select Alternate Action, you cannot use ATG = ON and TIMER = ON in procedures 8 and 9 that follow. Rev E Doc 01-20206 (6001521) 15 of 36 7. If you want a fully open gate to automatically close after a period of time, on switch S1, set TIMER to ON and adjust Reclose Timer pot R94 to set the time period. [. . . ] $ Exit or Open Loop: activation opens the gate. $ Interrupt or Reverse or Reopen Loop: activation reverses or stops the gate. $ Shadow Loop: activation prevents a fully open or closed gate from moving while a vehicle is inside the arc of a swing gate. Loop detector: An electronic device that is activated by a loop sensor sensing a metallic object. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER BG3000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER BG3000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag