User manual LIFT-MASTER BG3100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER BG3100. We hope that this LIFT-MASTER BG3100 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER BG3100.


Mode d'emploi LIFT-MASTER BG3100
Download
Manual abstract: user guide LIFT-MASTER BG3100

Detailed instructions for use are in the User's Guide.

[. . . ] (01Doc 6001343 (01-20299) Rev B INSTALLATION AND OPERATION INSTRUCTIONS FOR THE 3100MODEL BG 3100-X1 BARRIER GATE OPERATOR (-73 BOARD) TABLE OF CONTENTS THE LIFTMASTER MODEL BG 3100-X1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 BASIC INSTALLATION HINTS AND RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PART 1 SITE PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Verify that Manual Close fully closes the gate and that the close limit switch stops the gate. Mechanical The gate swings open and closed smoothly. There is no squeak or vibration in the gate when it is moving. There is no belt slippage when the gate moves or stops. Master/Slave system only: Both gates open and close at the same time (Bi-Parting gates only). Gate Sensitivity Left/Right Reverse sensitivity: Apply a bump to the opening and closing gate and verify that the gate stops or reverses. Inrush (Gate response time): Apply a bump to the gate as it initiates opening and closing and verify that the gate responds to the bump within a second. Maximum Retry Count If you want the gate to resume operation automatically after an occurrence of a Fault, program for Max Retry Count and Retry Pause Time. If you do not want the gate to resume automatically after a Fault, disable Max Retry Count. Give the opening gate a quick bump to generate a fault and verify retry operation. Entry Inputs Activate the CYCLE input (entry system), RADIO input (radio transmitter), and EXIT Loop input (driving over the exit loop) and verify that they fully open the gate. If Reclose Timer is enabled, it will close the gate. Activate the FIRE input (fire department switch) and verify that the gate fully opens and then closes immediately. If Reclose Timer is enabled, it will close the gate. Note: If the gate stops due to a Reverse Fault, readjust the gate sensitivity pots. Use the Manual Input commands to verify that: 5. 1. 2. 16 of 40 Doc 6001343 (01-20299) Rev B 7. 2. Alternate Action If you want the CYCLE input (Entry system) or RADIO input (Transmitter) to both open and close the gate, disable RECLOSE TIMER and ATG. Activate the CYCLE command, wait until the gate is fully open, the activate the CYCLE command again. The gate should close, verifying the Alternate Action operation. Note: If you select Alternate Action, you cannot enable the ATG and RECLOSE TIMER in procedures 8 and 9 that follow. Reclose Timer If you want a fully open gate to automatically close after a period of time, enable the RECLOSE TIMER. If you don't want the gate to close automatically, disable the RECLOSE TIMER. Activate any entry command (except Manual OPEN) to open the gate and verify the Reclose Timer operation. Note: Reclose Timer is not functional when the Manual OPEN command is used. Inside Interrupt Loop and ATG (when exiting) If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to restart when the vehicle drives off the Interrupt Loop, set Gate Type = Swing and disable the ATG. [. . . ] Shadow Loop: activation prevents a fully open or close gate from moving while a vehicle is inside the arc of a swing gate. Loop detector: An electronic device that is activated by a loop sensor sensing a metallic object. Master/Slave: A synchronized system containing a pair of gate operators. Maglock: An electric magnet which is used to secure the closed gate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER BG3100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER BG3100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag