User manual LIFT-MASTER CARWASH MODIFICATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER CARWASH MODIFICATION. We hope that this LIFT-MASTER CARWASH MODIFICATION user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER CARWASH MODIFICATION.


Mode d'emploi LIFT-MASTER CARWASH MODIFICATION
Download
Manual abstract: user guide LIFT-MASTER CARWASH MODIFICATION

Detailed instructions for use are in the User's Guide.

[. . . ] ADDENDUM Carwash Operator with Logic 2. 0 Circuit Models: T, GT, GH, H and J This addendum is to be used in conjunction with the owner's manual included with this operator. Refer to the manual for all mounting and wiring instructions. The carwash modification includes a TEFC motor, Watertight/Oiltight Control Enclosure, watertight/oiltight 3button control station, and nickel-plated chain in lieu of all standard components of the operator. 1. [. . . ] 48B9 X 3/8" (CGT ONLY) PHOTO CUP WASHER, SHIM ROLL PIN, 1/8" DIA. E-RING, 3/8" Qty 1 2 2 1 1 1 7 1 HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER - 1-800-528-2806 HOURS 7:00 TO 3:30 p. m. Time) MONDAY Through SATURDAY VARIABLE COMPONENT KITS 5011L2 5021L2 5023L2 5043L2 5025L2 5038L2 7511L2 7521L2 7523L2 7543L2 7525L2 7538L2 1011L2 1021L2 1023L2 1043L2 1025L2 1038L2 1511L2 1521L2 1523L2 1543L2 1525L2 1538L2 2023L2 2043L2 2038L2 3023L2 3043L2 3038L2 3353L2 5053L2 7553L2 1053L2 ITEM PART NO. DESCRIPTION 21-14182 Transformer, 115 Volts 3 21-5460 21-5575 25-2006 25-2008 25-2010 4 25-2015 25-2020 Transformer, 460 Volts Transformer, 575 Volts Overload, 6 Amp Overload, 8 Amp Overload 10 Amp Overload 15 Amp Overload 20 Amp 25-10296 Overload 2. 8-4. 4 Amp 25-11107 Overload 5. 2-8. 0 Amp 25-13840 Overload 2. 0-3. 0 Amp 11 03-8024K K-Line Contactor 2 ILLUSTRATED PARTS ­ ELECTRICAL BOX 17 17 14 15 L7 L9 S5 L6 S6 L1 3 4 8 5 L8 S2 L2 L9 L7 L3 3 RECOMMENDED POWER AND CONTROL CONNECTIONS Before installing power wiring or control stations be sure to follow all specifications and warnings described below. Failure to do so may result in severe injury to persons and/or damage to operator. For best protection against the environment follow directions below for recommended specifications for power and control wiring connections. SUGGESTED CONDUIT & FITTINGS Liquidtight Flexible Nonmetallic Conduit is permitted for use in both exposed and concealed areas and for electrical systems that require flexibility and protection from vapors, liquids or solids. LFNC conduit should be used for Liquidtight environments as stated by NEMA guidelines. All conduit and conduit fittings should be marked as "Liquidtight", conduit and fittings marked "Raintight" or "Wet Locations" are not to be automatically considered liquidtight. NOTE: Select all conduit and conduit connectors based on local code and application of job. ANY MAINTENANCE TO THE OPERATOR OR IN THE AREA NEAR THE OPERATOR MUST NOT BE PERFORMED UNTIL DISCONNECTING THE ELECTRICAL POWER VIA, THE MAIN DISCONNECT SWITCH. UPON COMPLETION OF MAINTENANCE THE AREA MUST BE CLEARED AND SECURED, AT THAT TIME THE UNIT MAY BE RETURNED TO SERVICE. DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. OPERATOR MUST BE PROPERLY GROUNDED AND CONNECTED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES. NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE CAPACITY. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED INDIVIDUAL. CONDUIT & FITTING PREPARATION The most efficient assembly of a liquidtight conduit and fitting system can be achieved, and optimum performance ensured, by adherence to simple conduit preparation and assembly techniques: 1. Square off ends of conduit by cutting the end of the conduit squarely using a hacksaw or similar tool, conduit manufacturers sometimes offer cutting jigs for this purpose. [. . . ] Insert gasketing around threaded area and secure in place with nut supplied. (Refer to manufacturer specifications for proper torque requirements). NOTE: For fitting attachments, always follow the manufacturers instructions. c 2000, The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CARWASH MODIFICATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER CARWASH MODIFICATION will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag