User manual LIFT-MASTER HJ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER HJ. We hope that this LIFT-MASTER HJ user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER HJ.


Mode d'emploi LIFT-MASTER HJ
Download

You may also download the following manuals related to this product:

   LIFT-MASTER HJ REPLACEMENT PARTS (1072 ko)

Manual abstract: user guide LIFT-MASTER HJ

Detailed instructions for use are in the User's Guide.

[. . . ] LO G IC OWNER'S MANUAL MODELS: L C O N TR O L FACTORY SET C2 Wiring J H HJ See pages 15 and 16 for other wiring configurations LOGIC CONTROL (VER. 2. 0) INDUSTRIAL DUTY DOOR OPERATOR PATENT PENDING The Maintenance Alert System TM allows the installer to set an internal Maintenance Cycle Counter. An LED on the 3-button station will signal when the set number of cycles is reached or when the opener requires immediate service. 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR Before attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. These instructions are intended to highlight certain safety related issues. [. . . ] If the timer has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the Timer To Close until the next command input. The Timer To Close will function from the programmable mid-stop with this wiring type. (NOTE: Requires Optional self monitoring photo eyes to operate. ) 15 ON ON TS 1 2 3 4 OFF WIRING TYPE PROGRAM SETTINGS CONT'D TYPE STATION T 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close, and stop, with open override and Timer To Close. Every device that causes the door to open, except a reversing device, activates the Timer To Close. Auxiliary controls can be connected to open input to activate the Timer To Close. If the Timer To Close has been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The Timer to Close will function from the programmable mid-stop with this wiring type. (NOTE: Requires Optional self monitoring photo eyes to operate. ) FSTS Momentary button contact for open, close and stop. Radio controls allowing open, close and stop. The single button station opens the door to the full open limit bypassing the mid stop and activates the Timer To Close, putting the operator in TS mode until the door reaches the down limit, or is stopped in travel. At which time the operator enters the B2 mode. (NOTE: Requires Optional self monitoring photo eyes to operate. ) C2 Failsafe 3 Button, 3 Button Radio Control Same functions as C2. Self Monitoring safety device must be installed to operate door. See Self Monitoring Safety Device Options below. ON ON T 1 2 3 4 OFF ON ON FSTS 1 2 3 4 OFF ON ON C2 FAIL SAFE 1 2 3 4 OFF ON ON B2 Failsafe 3 Button, 1 Button, 1 & 3 Button Radio Control Same functions as B2. Self Monitoring safety device must be installed to operate door. See Self Monitoring Safety Device Options below. B2 FAIL SAFE 1 2 3 4 OFF ON ON D1 Failsafe 2 Button, 3 Button Radio Control Same functions as D1. Self Monitoring safety device must be installed to operate door. See Self Monitoring Safety Device Options below. D1 FAIL SAFE 1 2 3 4 OFF ON ON E2 Failsafe 2 Button, 3 Button Radio Control Same functions as E2. Self Monitoring safety device must be installed to operate door. See Self Monitoring Safety Device Options below. E2 FAIL SAFE 1 2 3 4 OFF SELF MONITORING SAFETY DEVICE OPTIONS To use the operator in any of the Failsafe wiring modes, or Timer To Close wiring modes (TS, T, FSTS), a LiftMaster self monitoring safety device must be installed. [. . . ] Lubricate Check set screw tightness Check & adjust as required Check condition & tension Check & tighten as required EVERY 3 MONTHS OR 5, 000 CYCLES EVERY 6 MONTHS OR 10, 000 CYCLES EVERY 12 MONTHS OR 20, 000 CYCLES l l l l l l l t t t t t t t Sprockets Clutch Belt Fasteners Manual Disconnect Check & Operate Bearings & Shafts Check for wear & Lubricate S Use SAE 30 Oil (Never use grease or silicone spray). Motor bearings are rated for continuous operation. n Inspect and service whenever a malfunction is observed or suspected. n CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION ARE AVAILABLE 6 DAYS A WEEK CALL OUR TOLL FREE NUMBER - 1-800-528-2806 MONDAY THROUGH FRIDAY 5 A. M. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER HJ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER HJ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag