User manual LIFT-MASTER LGO50113L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER LGO50113L. We hope that this LIFT-MASTER LGO50113L user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER LGO50113L.


Mode d'emploi LIFT-MASTER LGO50113L
Download
Manual abstract: user guide LIFT-MASTER LGO50113L

Detailed instructions for use are in the User's Guide.

[. . . ] MODELS LGO50113R, LGO50113L LGO50113XR & LGO50113XL LIGHT DUTY GRILL OPERATOR OWNER'S MANUAL 2 YEAR WARRANTY Serial # Box Installation Date LISTED DOOR OPERATOR NOT FOR RESIDENTIAL USE TABLE OF CONTENTS SPECIFICATIONS Operator Specifications . . 3 ADJUSTMENTS Limit Switch Adjustment . . 11 PREPARATION Operator Preparation . . 12 TROUBLESHOOTING Testing the Operator . [. . . ] Remove the cover screws and set the cover aside (Figure 2). Connect the black (hot) wire to the screw on the brass terminal; the white (neutral) wire to the screw on the silver terminal; and the ground wire to the green ground screw. The operator must be grounded (Figure 3). Re-install the cover. Figure 2 Figure 3 Cover Screws Ground Wire Ground Screw Black Wires White Wires 7 I N S TA L L AT I O N O F D O O R C O N T R O L S THREE BUTTON STATION (STANDARD) Operator must be programmed to B2 Mode. Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware. Fasten the door control button securely with 6AB X 1-1/2" screws. If installing into drywall, drill 5/32" holes and use anchors provided. Run the wire up the wall to the operator. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a staple. Receiver terminal screws are located inside the operator access panel on the interface board. This includes pneumatic and electric edges, and through beam and retro reflective photo eyes. If your door does not have bottom safety photo eyes or a sensing edge and you wish to add a safety device to your application, please contact your local LiftMaster Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. IMPORTANT NOTES: · To install a sensing edge, ask for sensing edge connection kit LGOSE. This must be installed in order to add a sensing edge. · Proceed with Limit Switch Adjustments before making any sensing edge wiring connections to operator as described below. · Electrician must hard-wire the junction box to the operator electrical box in accordance with local codes. CAUTION It is strongly recommended that a safety photo eye or sensing edge be used in conjunction with the operator. TAKE-UP REEL: Take-up reel should be installed 12" above the top of the door. COIL CORD: Connect operator end of coil cord to junction box (not provided) fastened to the wall approximately halfway up the door opening. 9 CONNECTION PROCEDURE 1. Run the wires from the edge to the operator. Use a take-up reel or coil cord for this purpose. [. . . ] warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806, toll free, before dismantling this product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LGO50113L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LGO50113L will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag