User manual LIFT-MASTER ROBO SWING

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER ROBO SWING. We hope that this LIFT-MASTER ROBO SWING user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER ROBO SWING.


Mode d'emploi LIFT-MASTER ROBO SWING
Download
Manual abstract: user guide LIFT-MASTER ROBO SWING

Detailed instructions for use are in the User's Guide.

[. . . ] copyright © 2004 chamberlain professional products - www. eliteaccess. com TABLE OF CONTENTS 2 2 3 3 4-6 7 8 9 10 11 12 13 14 15 16 17 18 19 19 20 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35-36 37 38 39 40-41 41 42 43 Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Swing Gate Systems Warnings and Precautions Safely Operating Gate Configuration and Specifications Concrete Pad and Gate Attachment Standard Installation Compact Installation Gate Arm Installation Gate Movement Direction Adjustment of Output Shaft Earth Ground Rod DC Power Supply Connection "Optional" Solar Panel Surge Suppressor Terminal Input Connections Adjusting Gate Traveling Distance Timer Adjustment Reversing Sensor Warning Placard Placement Emergency Release Safety Device Wiring "Optional" Input Board Maglock Wiring Connection Optional 12 VDC Photo Beam Wiring 3-Push Button Wiring Connection 3-Push Button Wiring Master / Slave Single Operator Loop Size and Placement Master / Slave Loop Size and Placement Loop Installation and Number of Wire Turns Wiring Loop Detector to Operator Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions Control Board LED Descriptions Troubleshooting How to Reset Breaker Switch / How to Check Fuses Gate will not close!If you hear a "BEEP" sound (Audio Alarm) Robo Swing Parts Illustrations, Robo Swing Parts List Maintenance Elite Robo Swing Accessories Owners Checklist of Installation Please DO NOT Touch me!. . Unless you are an Authorized Service Technician! © COPYRIGHT 1992-2003 BY ELITE ACCESS SYSTEMS, INC. No part of this manual may be reproduced in any means; graphic, electronic, mechanical, or photocopied without the express written permission of the publisher of this material. Release 7 7/03 For Toll Free Technical Support: 1-888-ELITE-10 35483 1 ROLE OF SPECIFIERS AND DESIGNERS Specifiers and designers should design an automatic vehicular gate system to: · · · · · · · · · Utilize an operator suited for gate system type, size, frequency of use, location and user population. [. . . ] Too sensitive = if the gate stops or reverses by itself. Not sensitive enough = if the gate hits an object and does not stop or reverse. Do Not Touch Alarm Sensor Pot Minimum Sensitivity HEAVY GATE CHECK CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 Important Note! There is a "Heavy Gate" LED which will light up when the gate is heavier than normal. This is a diagnostic LED and the operator will still function normally when this indicator is on. SYSTEM ON ALARM SENSOR ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW REVERSE SENSOR OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO FIRE DEPT STRIKE OPEN L STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIGHT Maximum Sensitivity WARNING PLACARD PLACEMENT Warning placards need to be permanently mounted on BOTH sides of the gate. 20 W1 OPEN EMERGENCY 1 Unscrew Bolt Special tool required for the "optional" security bolt RELEASE 2 Lift Off Cover 3 Loosen Red Handle Gate can now be manually moved Grab the Gate to Make Adjustments Tighten the Red Handle, Replace the Cover and Bolt when Finished When the power is turned on again, the gate will readjust itself automatically. 21 SAFETY DEVICE WIRING Sensing Edges ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER CLASS 2 SUPPLY Sensor Edges Top of Gate Sensor Edge Wires 1 4 Important: gate will stop and reopen upon activation of device Photo Beam Entrapment Protection Optional input board needed to preform this function P/N Q412 PATENT PENDING Elite Part # A OMRON12V 7 8 9 10 11 12 13 16-Pin Plug 1 3 5 7 9 11 13 15 16 ­ FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + RADIO RECEIVER 2 4 6 8 10 12 14 3&4 Black Orange CHECK CHARGINGFUSE BOARD POWER POWER ­+ Blue Brown SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD HEAVY GATE 11 13 POWER CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO L FIRE DEPT STRIKE OPEN STOP TIMER UP PW SAFETY LOOP EXIT LOOP RADIO REC If photo beam is blocked the gate will stop. The gate will remain stopped until the beam is cleared. W1 OFF Cut W1 Jumper at Bottom of Board Wall OPEN TO RIGHT Danger Gate Open Mounted Reflector 22 W1 CLOSE Important: ON 60 0 OPEN "OPTIONAL" INPUT BOARD The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. 1&2 3&4 5&6 7&8 9 &10 d 11 & 4 12 & 7 13 & 14 15 & 16 Open Switch (N. O. ) Stop Switch (N. C. ) (Cut W1 Jumper at Bottom of Board) Timer Close Output to Slave Timer Input from Master (Close Command or Close Switch) (N. O. ) Alarm Output will be set off with very heavy gates or object preventing gate operation. (Not Burglar Alarm) (9 = +12 VDC, 10 = Alarm) Emergency Open Switch (Direct Command from Battery to Motor) Emergency Close Switch (Direct Command from Battery to Motor) Magnetic Lock - Dry Contact Relay (13 = Com, 14 = N. C. ) Center Loop Option (For Swing Gate Operators Only) W1 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL FIRE DEPT 23 OPEN MAGLOCK WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Elite Part# Q203) Custom Bracket Magnetic Lock Plate Magnetic Lock Gate Fence Elite Part # A MG 1300 Relay Contact Rating 0. 5 Amp - 125 VAC 1 Amp - 24 VDC Dry Contact Relay 14 13 N. C. Common Power for Maglock 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOAR D POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA CENTRAL CO NTROL OPEN 24 FIRE DEPT OPTIONAL 12 VDC PHOTO BEAM SAFETY WIRING ® ® AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­ ­ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON + + RADIO RECEIVER CLASS 2 SUPPLY Orange 1 (Elite Part # A OMRON 12V) (Failsafe) 4 White Blue 11 Brown 13 Power Photo Beam (Safety) 12 VDC It is best to use 12 VDC Failsafe Photo Beam Sensors for this Safety Option Failsafe Photo Beam: If a failsafe photo beam is not working or loses power or photo beam is blocked, then the photo beam will stop all gate operation. Important: If photo beam is blocked the gate will stop and reopen. The gate will remain open until the obstruction is cleared. Contact your local dealer for more information. 25 3­PUSH BUTTON WIRING CONNECTION The "Optional" input board MUST be used to perform this function. (Elite Part# Q203) There can be NO common wires within this 3-push button station. Open-N. O. Contact 2 4 8 N. C. 1 3 7 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE POWER BOARD POWER SYSTEM ON J2 ALARM SENSOR Cut W1 jumper at the bottom of Board to use the stop button in the 3-push button station REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA W1 CENTRAL CON TROL FIRE DEPT STRIKE OPEN STOP TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 OFF 0 CLOSE OPEN TO RIG HT 26 W1 OPEN 3­PUSH BUTTON WIRING MASTER/SLAVE The "Optional" input board MUST be used on both operators to perform this function (Elite Part# Q203). A 12 VDC Double Pull Double Throw (DPDT) 3 Amp Minimum Relay must be used (Not Included). There can be NO common wires within this 3-button station. 1 3 ® ® 2 4 D 12PDT ReVDC 3 Am lay p Mini Com Com NO NO AC ­ AC ACCESS SYSTEMS INC ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1­­456 ­+ ­ + POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON RADIO RECEIVER CLASS 2 SUPPLY Open-N. O. Contact mum +­ 13 + 11 ­ N. O. 7 8 8 N. O. Com Com 7 1 3 5 7 9 11 13 15 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 16-Pin Plug 2 4 6 8 10 12 14 16 16-Pin Plug CHECK CHARGINGFUSE BOARD POWER POWER CHECK SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY The timers MUST be turned OFF on BOTH operators. CHARGINGFUSE BOARD POWER POWER SYSTEM ON J2 ALARM SENSOR REVERSE SENSOR OVERLOAD POWER CHARGE OK HEAVY GATE BATTERY LOW OPEN RELAY CLOSE RELAY DC OPERATOR v 5M MADE IN USA DC OPERATOR v 5M MADE IN USA CENTRAL CONTRO L FIRE DEPT STRIKE OPEN CENTRAL CONTRO L FIRE DEPT STRIKE OPEN OPEN STOP ON 60 0 SAFETY LOOP EXIT LOOP RADIO REC STOP TIMER UP PW TIMER ON UP PW SAFETY LOOP EXIT LOOP RADIO REC 60 0 CLOSE CLOSE OFF W1 OFF OPEN TO RIGHT OPEN TO RIGHT W1 Cut W1 jumper at the bottom of each board to use the stop button in the 3-push button station 27 W1 OPEN SINGLE OPERATOR LOOP SIZE AND PLACEMENT It is VERY important to have enough separation between loops and gates to prevent false detection. Caution: Distance "E" must be a minimum of 4 feet away from open gate! Maximum gate length for Robo Swing is 16 Feet. Drawing not to scale E open gate Inside Safety Loop Distance from Out Exit Loop H F Center Loop D C Outside Safety Loop In A I G B End of open gate Outside Safety Loop: If A = Then C = Center Loop: 6 Feet 4 Feet 9 Feet 4. 5 Feet 12 Feet 5 Feet 15 Feet 5 Feet 18 Feet 5. 5 Feet 21 Feet 6 Feet This loop must have enough space between loop and gate when opened or closed. If driveway is smaller than 18 ft, then D must be 4. 5 ft If driveway is bigger than 18 ft, then D must be 5 ft If B = Then E = Inside Safety Loop 6 Feet 4 Feet 9 Feet 4. 5 Feet 12 Feet 5 Feet 15 Feet 5 Feet If there is no center loop, then F 4 ft If there is a center loop, then F = B or G which ever is largest. Exit Loop H = G or I which ever is largest. This is for a typical single operator loop installation. Individual circumstances may alter dimensions. For toll free technical support: 1-888-ELITE-10 35483 28 MASTER/SLAVE LOOP SIZE AND PLACEMENT It is VERY important to have enough separation between loops and gates to prevent false detection. Caution: Distance "E" must be a minimum of 4 feet away from open gate! Maximum gate length for each Robo Swing is 16 Feet. Drawing not to scale E open gate Distance from Out Exit Loop H Inside Safety Loop F Center Loop D C Outside Safety Loop In Exit Loop A I G B E open gate End of open gate Distance from Outside Safety Loop: If A = Then C = Center Loop: 6 Feet 4 Feet 9 Feet 4. 5 Feet 12 Feet 5 Feet 15 Feet 5 Feet 18 Feet 5. 5 Feet 21 Feet 6 Feet This loop must have enough space between loop and gate when opened or closed. If driveway is smaller than 18 ft, then D must be 4. 5 ft If driveway is bigger than 18 ft, then D must be 5 ft If B = Then E = Inside Safety Loop 6 Feet 4 Feet 9 Feet 4. 5 Feet 12 Feet 5 Feet 15 Feet 5 Feet If there is no center loop, then F 4 ft If there is a center loop, then F = B or G which ever is largest. H = G or I which ever is largest. This is for a typical master/slave loop installation. Individual circumstances may alter dimensions. [. . . ] For parts, refer to Robo Swing parts page and this page. For parts, refer to Robo Swing parts page and this page. If you need further assistance, please call your local service company. If you need further assistance, please call your local service company. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER ROBO SWING

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER ROBO SWING will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag