User manual LIFT-MASTER SJ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SJ. We hope that this LIFT-MASTER SJ user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER SJ.


Mode d'emploi LIFT-MASTER SJ
Download
Manual abstract: user guide LIFT-MASTER SJ

Detailed instructions for use are in the User's Guide.

[. . . ] OWNER'S MANUAL MODEL SJ SPEED JACKSHAFT OPERATOR TH E CH EL AM MHU BE RS RL T, AIN IL LI GRO NO IS UP 60 , IN 12 C. 6 41 B6 PL AC E LI ST ED RA TIN G LA BE L DO OR HE RE OPE RA TO R NOT FOR RESIDENTIAL USE 2 YEAR WA R R A N T Y Serial # (located on electrical box cover) Installation Date Wiring Type SPECIFICATIONS MOTOR TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Synchronous continuous duty ENCLOSURE:. . . . . . . . . . . . . . . . . . . . . . . ODP NEMA 56c face mount. HORSEPOWER: . . . . . . . . . . . . . . . . . . . 1 HP Single or Three phase SPEED: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1725 RPM VOLTAGE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 & 230 Single phase 230 & 460 Three phase 575 Three phase CURRENT: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See motor nameplate ELECTRICAL TRANSFORMER: . . . . . . . . . . . . . . . 1PH: 120/240 VAC 24VAC 3PH: 240/480 VAC 24VAC 3PH: 575 VAC 24VAC CONTROL STATION: . . . . . . . . NEMA 4 three button station. OPEN/CLOSE/STOP WIRING TYPE: . . . . . . . . . . . . . . . . . . . Standard C2 Wiring- Standard operators are shipped from the factory set for C2 wiring, which requires momentary contact to open, constant pressure to close, stop on reverse. [. . . ] Mount the wall mounted starter where the door is visible, but not directly underneath the door, operator, or mounting hardware. MOUNT WARNING NOTICE IMPORTANT: Mount WARNING NOTICE beside or below the wall mounted starter. WARNING INSTALL THE WALL MOUNTED STARTER WHERE THE DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND ITS HARDWARE. IF STARTER CANNOT BE INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN THE CONTROL STATION IS USED TO ACTIVATE THE DOOR, A REVERSING EDGE MUST BE INSTALLED ON THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A REVERSING EDGE UNDER THESE CIRCUMSTANCES MAY RESULT IN SERIOUS INJURY OR DEATH TO PERSONS TRAPPED BENEATH THE DOOR. W CAUTION TH E C EL HA MH MB UR ER ST LA , IL IN LI GR NO O IS UP, 60 IN 12 C 6. OPEN WARNING CLOSE 41 B6 LI PL AC E RA TIN G STE D LA BE L DO OR TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR HE RE OP ER ATO R WARNING Notice 6 CONTROL WIRING (con't) Radio Controls All radio controls must have dr y contact relay outputs. Power for radio is to be supplied by an outside source. Do not take power from the components inside the electrical enclosure. WARNING DO NOT USE RADIO CONTROLS WITH YOUR OPERATOR UNLESS YOU HAVE INSTALLED SOME TYPE OF ENTRAPMENT PROTECTION DEVICE. THE USE OF RADIO CONTROLS PRESENTS POTENTIAL HAZARDS DUE TO THE USER'S ABILITY TO OPEN OR CLOSE THE DOOR WHEN OUT OF SIGHT OF THE DOOR. W CAUTION Additional Access Control Equipment Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD WIRING CONNECTIONS diagram. Any control with a normally (N. O. ) isolated output contact may be connected in parallel with the OPEN button. More than one device may be connected in this manner. Use 16 gauge wire or larger for all controls. 2) Terminal J2-19 and J2-20 will close when the door is stopped at any position other than fully closed. 3) Terminal J2-21 and J2-22 will close when the door is in motion. Single button control is available as an optional device and is wired to terminals J2-11 and J2-12 on the LMPLC board. POWER WIRING POWER WIRING CONNECTIONS 1. Connect power wires to the J1 terminal block located on the Printed Circuit Board (shown below). CONTROL STATION WIRING CONTROL WIRING CONNECTIONS 1. Connect control wires to the J2 terminal block located on the Printed Circuit Board (shown below). (See wiring diagram page 11, 13, and 15) (See wiring diagram page 11, 13 and 15) GROUND WIRING 1. Connect earth ground to chassis ground screw in the electrical box enclosure marked with the label shown below. 2. Press OPEN push button and observe direction of door travel and then Press the STOP button. If door did not move in the correct direction, check for improper wiring at the control station or between operator and control station. (See page 19) 40-10033B 2. Use same conduit entry into the electrical box as the power wiring. (See wiring diagram page 11, 13 and 15) 8 OPTIONAL CONTROL SETTINGS NOTE: All functions are independent of each other and do not require other control settings to be set at any certain configuration. For dip switch location refer to illustration below. All switches are factory preset to the "OFF" position. SI-1 SI-2 SI-3 SI-4 WIRING TYPE - B2 wiring in the OFF position and C2 wiring in the ON position. NOT USED NOT USED INFRARED EYES STATE - The operator will support Chamberlain (CPS LN4) Infrared Eyes when enabled, and ignore IR inputs when disabled. ON (C2) ON (IR'S ENABLED) 1 2 3 4 1 2 3 4 OFF (B2) OFF (IR'S DISABLED) DIP SWITCH (S1) TERMINAL BLOCK (J2) TERMINAL BLOCK (J1) NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. [. . . ] Limit switches do not hold their settings. Door `drifts' when motor shuts off. Operator does not shut off at full OPEN or at full CLOSE position. Adjust nut to proper torque. Brake inoperative or worn. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SJ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SJ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag