User manual LIFT-MASTER SL1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SL1000. We hope that this LIFT-MASTER SL1000 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER SL1000.


Mode d'emploi LIFT-MASTER SL1000
Download
Manual abstract: user guide LIFT-MASTER SL1000

Detailed instructions for use are in the User's Guide.

[. . . ] Doc 6001204 (01-20260) Rev C INSTALLATION AND OPERATION INSTRUCTIONS FOR THE MODEL SL 1000-B1 SLIDE GATE OPERATOR (-68 BOARD) TABLE OF CONTENTS SAFETY SUMMARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 BASIC INSTALLATION HINTS AND RULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PART 1 SITE PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOCATION AND LAYOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Note: If you select Alternate Action, you cannot use ATG = ON and TIMER = ON in procedures 8 and 9 that follow. If you want a fully open gate to automatically close after a period of time, on switch S1, set TIMER to ON and adjust Reclose Timer pot R94 to set the time period. If you don't want the gate to close automatically, on switch S1, set TIMER to OFF. Activate any entry command (except Manual OPEN) to open the gate and verify the Reclose Timer operation. NOTE: Reclose Timer is not functional when the Manual Open command is used. Inside Interrupt Loop and ATG (when exiting) 1. If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to restart when the vehicle drives off the Interrupt Loop, on switch S1, set SLIDE and ATG to OFF. If you want the gate to stop when a vehicle drives onto the Interrupt Loop and to close when the vehicle drives off the Interrupt Loop, on switch S1, set SLIDE to OFF and ATG to ON. If you want a closing gate to open when a vehicle drives on the Interrupt Loop, on switch S1, set SLIDE to ON and ATG to OFF. If you want a closing gate to stop when a vehicle drives on the Interrupt Loop and an opening or closing gate to close when the vehicle drives off the Interrupt Loop, on switch S1, set SLIDE and ATG to ON. Activate the CYCLE command, drive over the Interrupt Loop, and verify its operation. Rev C Doc 6001204 (01-20260) Page 18 of 40 10. Interrupt Bar While the gate is opening , push on the Interrupt Bar. Maglock Verify that the maglock activates when the gate is fully closed. To automatically close a fully open gate after power is restored, on switch S1, set TIMER to ON. Open the gate fully, then cycle the unit power switch to verify Automatic Gate Closure operation. Verify that switch S3 (Power Fail Open Direction switch) is set to the desired position (Figure 12). Record switch S3 setting in the space provided in the Maintenance Section. It is essential that maintenance personnel know what the gate will do when power is turned off during maintenance. Rev C Doc 6001204 (01-20260) Page 19 of 40 M. FINAL ASSEMBLY OF GATE OPERATOR Figure 19. Gate Operaor Final Assembly IMPORTANT SAFETY PROCEDURE If switch S3 (Power Fail Open Direction switch) is set to OPEN the gate, cycle the gate to its fully open position before performing step 1. If switch S3 (Power Fail Open Direction switch) is set to CLOSE the gate, cycle the gate to its fully closed position before performing step 1. Turn off power to the gate operator at the circuit breaker and wait for one minute. [. . . ] Shadow Loop: activation prevents a fully open or closed gate from moving while a vehicle is inside the arc of a swing gate. Loop detector: An electronic device that is activated by a loop sensor sensing a metallic object. Master/Slave: A synchronized system containing a pair of gate operators. Maglock: An electric magnet which is used to secure the closed gate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SL1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag