User manual LIFT-MASTER SW2200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LIFT-MASTER SW2200. We hope that this LIFT-MASTER SW2200 user guide will be useful to you.

Lastmanuals help download the user guide LIFT-MASTER SW2200.


Mode d'emploi LIFT-MASTER SW2200
Download
Manual abstract: user guide LIFT-MASTER SW2200

Detailed instructions for use are in the User's Guide.

[. . . ] When the gate closes, the single button will have no effect. However, you may program the "STOP" or "REVERSE" options (see below). Selectable options include the following: GATE CONDITIONS OPENING PROGRAMMABLE FUNCTIONS POSSIBLE STOP OPEN ONLY STOP, NO TMR RST STOP REVERSE MID-STOP OPEN MID-STOP REVERSE Table 1: Programmable Options CLOSING AT MID-STOP If the gate is . If "TIMER TO CLOSE" is activated (see p. [. . . ] Press and hold (+) or (­) to open the gate. When the gate reaches the desired open limit position, release (+) and (-) and press ENTER. The Open Limit LED will blink to indicate that the open limit position is accepted but not yet stored in the memory. Press ENTER to test the gate's limits. The gate will automatically close, open, and finally close to the programmed close/open limit positions. Press any key to stop the gate during the limit test. When the operator finishes the test, the Close Limit and Open Limit LEDs will stay lit to indicate that the limit positions are now stored in the system's memory. DISPLAY PROMPT LIMITS MENU ENTER TO CHANGE RESET LIMITS (+) (+) TO CONTINUE (­) TO EXIT SET CLOSE LIMIT (+/­) TO POSITION SET CLOSE LIMIT ENTER TO SET 6 7 SET OPEN LIMIT (+/­) TO POSITION SET OPEN LIMIT ENTER TO SET 8 PRESS ENTER TO TEST LIMITS 9 Doc 01-16169 Rev B LiftMaster 7 Setting the Gate Operator Speed This feature allows you to change the speed of the gate. Please note that max speed (normal gate speed) and min speed (decelerated gate speed) have their own minimum and maximum range. For the SW2200, Table 4 provides speed settings based on the total amount of time it takes the gate to fully open or close. Refer to Table 3 and Table 4 to select proper gate speeds for the SLMAX and SW2200: MAX GATE SPEED (INCHES/SEC) 12" 11" 10" 9" 8" 7" 6. 8" MIN GATE SPEED (INCHES/SEC) 8. 8" 8" 7" 6" 5" 4. 2 --- PROGRAMMED SETTING 170 157 144 130 117 104 100 (Min. ) PROGRAMMED SETTING 120 (Max. ) 110 97 83 70 60 (Min. ) --- Table 3: Max and Min Gate Speeds for the SLMAX GATE OPEN OR CLOSE TIME (SEC) 14 15 16 17 18 19 20 21 22 23 24 25 PROGRAMMED SETTING 220 (Max. ) 200 190 170 155 145 130 120 115 110 105 100 (Min. ) Table 4: Max Gate Speed for the SW2200 Doc 01-16169 Rev B 8 SLMAX/SW2200 Programming Instructions NOTE: The open/close time settings in Table 4 are valid if: (1) You install the gate with the gate dimensions recommended in the installation manual. -and(2) The Open and Close Deceleration Limits are programmed at the minimum (100) setting. -and(3) The Min Gate Speed is programmed to 120. Factory Defaults SLMAX = MAX SPEED: 220 MIN SPEED: 60 = MAX SPEED: 220 MIN SPEED: 60 SW2200 Setting the Gate Speed To set the operator speed, follow the steps below: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the OPERATOR SPEED option and press ENTER. Press (­) or (+) to set the maximum gate speed. NOTE: Maximum speed refers to the speed of the gate during opening or closing. Press (­) or (+) to set the minimum gate speed. NOTE: Minimum speed refers to the speed of the gate when it slows down prior to reaching the open or close limit. MIN SPEED: (See Table) (+/­) TO ADJUST DISPLAY PROMPT OPERATOR SPEED MAX SPEED: (See Table) (+/­) TO ADJUST Doc 01-16169 Rev B LiftMaster 9 Setting the Deceleration Limits This feature allows you to set the distance during which the gate starts to slow down prior to stopping at the open or close limit. Set the Open Deceleration Limit FACTORY DEFAULT = MEDIUM To set the Open Deceleration Limit, follow these steps: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the OPEN DECEL LIMIT option and press ENTER. Press (­) or (+) to set the distance. DISPLAY PROMPT OPEN DECEL LIMIT __ __ __ I __ __ __ [LESS 3 Press ENTER to save. MORE Set the Close Deceleration Limit FACTORY DEFAULT = MEDIUM To set the Close Deceleration Limit, follow these steps: PROCEDURES 1 2 Pressing the MENU buttons (!"), locate the CLOSE DECEL LIMIT option and press ENTER. Press (­) or (+) to set the distance. [. . . ] OFF = Alarm does not sound off during gate movement. 1-9 = Alarm sounds off during gate movement. Gate will start after set number of seconds (1-9). DISPLAY PROMPT OPERATOR WARNING OPERATOR WARNING DELAY START: (0-9) Setting the Gate's Timer to Close FACTORY DEFAULT = OFF This feature allows you to set the time (in seconds) the gate stays open prior to closing automatically. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SW2200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER SW2200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag