[. . . ] TriCodeTM TCR2 Dual Channel Receiver U. S. Patent Pending SPECIFICATIONS Output Rating: 5 Amps 28VAC or DC Max. Power: 12VDC or 18 to 34VAC/DC, @ 30ma RF Frequency: 300 or 310MHz Accessory Transmitters: TC1, TC2 and TC4 This device complies with FCC Rules Part 15 and IC Canada Rules and Regulations. [. . . ] The door/gate could close and cause serious injury or death. Do not allow children to operate the door control push button or the remote control transmitters. Install the receiver (and all door control push buttons) out of the reach of children and away from all moving parts of the door and door hardware, but where the door/gate is visible. TABLE OF CONTENTS DESCRIPTION PAGE Disconnect power to opener before installing receiver or removing/replacing receiver cover. Setting Power Supply Selection. . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setting Output Relay Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Setting the Configuration Switch. . . . . . . . . . . . . . . . . . . . . . . . . 3 Setting DIP Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Power Supply Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 POWER SWITCH SETTINGS CAUTION:To avoid possibility of duplicating codes in adjacent systems, all transmitters and receivers should be re-coded prior to operation. Unless using maximum number of codes the following four codes should not be used: · All DIP Switches ON · All DIP Switches OFF · DIP Switches alternating ON/OFF · DIP Switches alternating OFF/ON. Step 1 Power Supply Selection Setting The TriCodeTM receiver is factory set for 24 volt power input if 12 volt is required. Remove back cover of receiver by removing screws. Set jumper to the 12 volt setting (Refer to figure 1). Receivers should be installed at least 5 feet apart to avoid cross-talk. After completing installation, operate transmitter outside of building to make certain the chosen DIP switch setting does not operate with nearby garage door operators and/or security systems. If so, select another DIP switch setting and check the coded signal again. Repeat as necessary. RECEIVER MOUNTING Mount receiver to wall using #6 hardware (Not Supplied). Hardware used will depend on mounting application. (Refer to figure 1 for receiver mounting hole locations). BACK VIEW FIGURE 1 MOUNTING HOLES 2 OUTPUT RELAYS & CONFIGURATION SWITCH SETTINGS Step 2 Setting Output Relay Mode The TriCodeTM receiver is factory set for momentary relay output "MNT". (a) Momentary mode: The output relay will be on for . 5 seconds before turning off. (b) Constant pressure mode: Output relay is continuously on while receiving matching/valid ID code from transmitter. The output relay will turn off immediately once receiver does not receive a matching/valid ID code from the transmitter (Refer to figure 3). NOTE: If constant pressure mode is desired, open front cover and move mode jumper from "MNT" to "CST" (Refer to figure 2). [. . . ] If so, try reversing the setting on the TriCodeTM DIP switch (Refer to figures 4 and 5). Note: In 'LINEAR/DELTA-3TM' mode (8-bits system) the last 2 bits (DIP #9 & 10) settings are ignored. They can be left in either `ON' or `OFF' settings. FIGURE 4 FIGURE 5 Step 5 Power Supply and Relay out Connections There are six wires exiting the housing (Refer to figure 6): RED & BLACK - POWER INPUT BROWN & BLUE - CHANNEL 1 RELAY OUTPUT WHITE & GREEN - CHANNEL 2 RELAY OUTPUT FIGURE 6 01-17468C © 2000, The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER TCR2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER TCR2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag