User manual M-TECH SX 35 DSC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual M-TECH SX 35 DSC. We hope that this M-TECH SX 35 DSC user guide will be useful to you.

Lastmanuals help download the user guide M-TECH SX 35 DSC.


Mode d'emploi M-TECH SX 35 DSC
Download
Manual abstract: user guide M-TECH SX 35 DSC

Detailed instructions for use are in the User's Guide.

[. . . ] SX 35 DSC SELECT VOL DISTRESS SQ MENU EXIT HI/LO SCAN END MEM 16 CALL SX 35 DSC ENT LIFT HERE OFF OWNER'S HANDBOOK Declaration of Conformity I hereby declare that the product Maritime transceiver : M-TECH SX 35 DSC (Name of product, type or model, batch or serial number) satisfies all the technical regulations applicable to the product within the scope of Council Directives 73/23/EEC, 89/336/EEC and 99/5/EC : EN 60945:1997 ETSI EN 301 843-1, -2 V1. 1. 1: 2001-02 ETSI EN 301 025-1: V1. 1. 2: 2000-08 ETSI EN 301 025-2 : V1. 1. 1: 2000-08 ETSI EN 301 025-3: V1. 1. 1: 2001-05 (Title(s) of regulations, standards, etc. ) All essential radio test suites have been carried out. Rasek - Address : Boelwiese 5, 91320 Ebermannstadt, Germany Identification Number : 0678 MANUFACTURER or AUTHORISED REPRESENTATIVE : - Address : Pony Electric Corporation No. 202, 6-28, Akasaka 9-chome, Minato-ku, Tokyo 107-0052, Japan. This declaration is issued under the sole responsiblility of the manufacturer and, if applicable, his authorised representative. [. . . ] The MMSID does not appear in the directory list. The DIRECTORY topic appears in the display. · To edit an existing name or MMSID in the directory: · · MENU Press the ENT key. DSC Calling Directory entries appear in the display. The directory stores a maximum of 32 entries which are displayed four at a time. Use the SELECT knob to move the cursor to the entry name for editing. · 24 SX 35 DSC · Press the ENT key. The DIRECTORY NAME/ID screen appears presenting the name and MMSID for the selected directory entry. The blinking cursor is positioned at the start of the entry's name. Press the ENT · · · · · or ENT key. The cursor becomes an underline instead of a blinking square and moves to the first character position. Use the SELECT knob to move the underline cursor to the character position needing change. The blinking cursor appears. Use the SELECT knob or microphone keys to change the contents of the character to the new value. When new value is correct, press the ENT key or the ENT key. If more ENT characters in the same line need changing, use the ENT or or EXIT key to move the blinking cursor to the next desired character. If no more changes are desired on the same line, use the MENU key to move the cursor back to the start of the line. · When both the name and MMSID are correct, press the the data and exit to the directory listing. MENU key to save LAMP Allows adjustment of illumination for the LCD display, keypad and microphone keypad. · · · Press the MENU key. Menu topics appear in the display. Use the SELECT knob to position the cursor on the LAMP topic. The BRIGHTNESS adjust screen appears in the BRIGHTNESS LO HI USA INT Brightness Control · Use the SELECT knob or microphone keys 0~3 to change the setting. SX 35 DSC 25 · Press the ENT or MENU key to store the setting and exit. CONTRAST Allows adjustment of LCD display contrast for best readability in varying lighting conditions. · · · Press the MENU key. Menu topics appear in the display. Use the SELECT knob to position the cursor on the CONTRAST topic. The CONTRAST adjust screen appears in the dis- CONTRAST LO HI USA INT Contrast Control · · Use the SELECT knob or microphone keys 0~7 to change the setting. Press the ENT or MENU key to store the setting and exit. DATA SET Provides On/Off control for display of Lat/Lon, Date/Time, Speed/Course, and Manual Lat/Lon. [. . . ] · SOG/COG& LL Position (3 digit for seconds). · Time & Manual LL Position (no seconds). · No Data. Data Output: DSC call formats can be sent to PC & printer using 4800 baud and standard Terminal program. Three scanning Modes: · All Scan · Memory Scan (nonvolatile) · Priority Scan Noisy channels can be temporarily deleted in All Scan Mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE M-TECH SX 35 DSC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual M-TECH SX 35 DSC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag