User manual MAKITA AC320H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAKITA AC320H. We hope that this MAKITA AC320H user guide will be useful to you.

Lastmanuals help download the user guide MAKITA AC320H.


Mode d'emploi MAKITA AC320H
Download

You may also download the following manuals related to this product:

   MAKITA AC320H ANNEXE 907 (4811 ko)

Manual abstract: user guide MAKITA AC320H

Detailed instructions for use are in the User's Guide.

[. . . ] Air Tank pressure gauge Regulated pressure gauge "HP" Air regulator "HP" Quick coupler "HP" (Air outlet) Regulated pressure gauge "RP" Air regulator "RP" Quick coupler "RP" (Air outlet) Drain valve Operation panel 9 bar)* SCFM @ 330 PSIG (L/min @ 23 bar)* Bore x Stroke x Qty Tank Size Weight Dimensions (L x H x W) Lubrication Protective earthing Protective structure Working temperature Working humidity Height above sea level Storage temperature Storage humidity Outlet Max Pressure "HP" (Exclusively for High Pneumatic Use) Outlet Max Pressure "RP" (Exclusively for Regular Pneumatic Use) Noise Sound Pressure Level (Lpa) Sound Power Level (Lwa) Uncertainty K AC320H 220 - 240 V AC 7A 50 Hz ± 1 Hz 2 HP 2, 500 min-1 2. In consequence of operating conditions, environments and the hours of operation, outlet pressure is changed. ⷠDue to our continuing programme of research and development, the specifications herein are subject to change without notice. ⷠSpecifications may differ from country to country. [. . . ] Work in an area equipped with good cross ventilation. ⷠRead and follow the safety instructions provided on the label or safety date sheet for the material you are spraying. Use an approved respirator designed for use with your specific application. WARNING: Risk from Noise WHAT CAN HAPPEN The air compressor generates noise exceeding 80 dB (A) during operation. It may cause the operator and people around it to suffer hearing loss. WARNING: Risk from Compressed air WHAT CAN HAPPEN The compressed air stream can cause soft tissue damage, and can propel dirt, chips, loose particles and small objects at high speed, resulting in property damage or personal injury. hOW TO PRIVENT IT · Always wear approved safety glasses with side shields when using or maintaining the compressor. ⷠNever point any nozzle or sprayer toward any part of the body or other people or animals. ⷠAlways turn the compressor off and bleed pressure from the air line before attempting maintenance, attaching tools or accessories. WARNING: Risk from Moving Parts WHAT CAN HAPPEN The compressor cycles automatically when the switch is in the on position. If you attempt repair or maintenance while the compressor is operating or plug in, you can expose yourself to moving parts. These moving parts can cause serious injury. hOW TO PRIVENT IT · Always unplug the compressor and release air pressure from the tank and any attachments before attempting any maintenance. ⷠNever operate the compressor with guards or covers which are damaged or removed. ⷠKeep your hair, clothing, and gloves away from moving parts. Loose clothes, jewellery, or long hair can be caught in moving parts. ⷠAir vents may cover moving parts and should be avoided as well. Never put off the cover of the compressor except MAKITA authorized dealer. WARNING: Risk of Burn WARNING: Do not operate the portable compressor with the doors or enclosures open. WHAT CAN HAPPEN Contact with hot parts such as the compressor head or outlet tubes could result in a serious skin burn. hOW TO PRIVENT IT · Never touch hot components during or immediately after operation of the compressor. Do not reach around protective shrouds or attempt maintenance until unit has been allowed cool. [. . . ] Corrosion and damaging of a parts, tank bursting could lead to personal injury and property damage. NOTE: If drain valve is plugged, release all air pressure with air tools and accessory equipments. If you are not able to do so, arrange for repairs by MAKITA authorized dealer. Using the air tool or accessory, bleed the tank pressure down to zero. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAKITA AC320H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAKITA AC320H will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag