User manual MARTIN AUDIO LE1500S SCHEMATICS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MARTIN AUDIO LE1500S. We hope that this MARTIN AUDIO LE1500S user guide will be useful to you.

Lastmanuals help download the user guide MARTIN AUDIO LE1500S.


Mode d'emploi MARTIN AUDIO LE1500S
Download
Manual abstract: user guide MARTIN AUDIO LE1500SSCHEMATICS

Detailed instructions for use are in the User's Guide.

[. . . ] 22 NomadLink network and PC editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 7. 7. 1 NomadLink network in the amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 7. 7. 2 Connection and setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 7. 7. 3 NomadLink network cable lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7. 7. 4 Ethernet network cable lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 7. 7. 5 DeviceControl editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 7. 5 7. 6 7. 7 8 APPENdIx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 8. 1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 8. 2 FAQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 8. 3 Bench test the amplifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 8. 4 Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 8. 5 BTU specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 9 TEChNICAL SPECIfICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 10 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Q Series Operation Manual 3 All material © 2007. Subject to change without notice. 2 APPROVALs This equipment conforms to the requirements of the EMC directive 89/336/EEC, amended by 92/31/EEC and 93/68/EEC and the requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC. Standards applied: EMC Emission EN55103-1, E3 EMC Immunity EN55103-2, E3, with S/N below 1% at normal operation level. Electrical Safety EN60065, Class I This equipment is tested and approved according to the U. S. [. . . ] Output operation and connection Screw-terminal connectors with + and ­ poles are provided at each channel output for connection of the speakers. Two electronically balanced Phoenix-type inputs are available. Follow the +, ­ and Ground labels when connecting the input signal. If an unbalanced connection is desired this can be achieved by summing the minus ("COLD") and Ground terminals and using the + terminal as the "HOT" signal. For the best possible performance, the summing of ground and minus wires should be done at the source unit end of the cable (e. g. Four connectors are supplied for attaching cables to the inputs. The type of connector used is: Phoenix Contacts, Part number MSTB 2, 5/3-STZ-5, 08 When linking the same source signal to several input channels, be aware that there is a limit to the number of channels an output source can "drive". a DSP crossover unit) can drive up to 4 amplifier channels before line-drivers would be required to buffer the signal. Make sure that the speaker cables are connected correctly and tightly, and that accurate polarity is maintained to all speakers in the system. As the amplifier outputs produce high voltage, do not connect or disconnect speaker cables when the mains power is on. Also, attach the safety cover on the speaker terminals for safe operation and to comply with electrical product approvals. 16 Q Series Operation Manual All material © 2007. The VPL allows you to set the correct maximum output peak power for optimum performance with the connected speakers. The correct setting depends on the system type (lo-or hi-impedance) and the specific load connected to the channel. Since each channel can be configured to deliver either very high voltage peak power OR high current draw at low impedances, it is important to set the VPL correctly. To configure an individual output channel for a constant voltage system, you simply adjust the DIP switches to the desired voltage. However, when using an output for a low impedance system (2, 4, 8 or 16 ohms), then sometimes you need to adjust the VPL to a lower setting to avoid either delivering excessively high continuous power to the Q Series Operation Manual 17 All material © 2007. Subject to change without notice. 7 OPERATION AND PERFORMANCE speaker or overheating of the output channel through high current draw. For example, with a very "hot" conti-nuous output signal, the temperature could rise to a critical level and activate Temp warning or even Temp Mute. Lowering the VPL setting normally will solve this situation. If the Current Peak Limiter is active or indicates low impedance, lowering the VPL setting can rectify this situation as well. 7. 4. 6 Constant Voltage 70 V and 100 V systems setup and operation When using Q Series amplifiers to drive constant voltage (hi-impedance) speaker systems at 70 Vrms or 100 Vrms, you can in most cases simply connect the speakers to the amplifier output terminals, select the correct VPL setting, and place the amplifier in service. 7. 4. 7 Output Current Peak Limiter (CPL) The Current Peak Limiter (CPL) ensures that the amplifier will not be damaged by trying to deliver more current to the outputs than that physically possible for the transistors. [. . . ] continuous output power all 4 channels driven at VPL: 141V and Gain: 35dB 16 ohms (per ch. ) 8 ohms (per ch. ) 4 ohms (per ch. ) 2 ohms (per ch. ) Hi-Z: 70V/100V (per ch. ) 650 W 1200 W 1700 W 1200 W 1600 W 625 W 1000 W 1200 W 600 W 900 W Mains connector, 230V CE version Mains connector, 115V ETL version Maximum mains current consumption, 230V version Maximum mains current consumption, 115V version 16A / CEE7 20 A / 5-20P 11. 2 A 22. 4 A 16A / CEE7 20 A / 5-20P 8, 7 A 17, 4 A PALTM reduces the maximum output power keeping the power supply in safe operating area and/or preventing excessive current draw tripping the mains breaker. The Voltage Peak output values translate to rms Voltage for a sine wave as: peak/1. 41 = Vrms. 141V peak is 100V rms and 100V peak is 70Vrms. This means that the outputs can be set for high impedance loads without the use of an external transformer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MARTIN AUDIO LE1500S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MARTIN AUDIO LE1500S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag