User manual MARTIN ATOMIC 3000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MARTIN ATOMIC 3000. We hope that this MARTIN ATOMIC 3000 user guide will be useful to you.

Lastmanuals help download the user guide MARTIN ATOMIC 3000.


Mode d'emploi MARTIN ATOMIC 3000
Download
Manual abstract: user guide MARTIN ATOMIC 3000

Detailed instructions for use are in the User's Guide.

[. . . ] Atomic 3000 user manual 424 239 450 5 x Ø12. 20 90 150 84 496 143 234 © 2001-2005 Martin Professional A/S, Denmark. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. P/N 35000094, Rev D Contents Safety information . . 25 Atomic 3000 user manual 3 SAFETY INFORMATION Warning: This product is for professional use only! [. . . ] 2 Connect up to 31 additional fixtures output-to-input. 3 Insert a termination plug in the output of the last fixture on the link. DA T A · CONNECTION TIPS Use shielded twisted-pair cable designed for RS-485 devices: standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to 300 meters (1000 ft. ). Use heavier gauge cable and/or an amplifier for longer runs. · Never use both outputs to split the link. To split the serial link into branches use a signal splitter. · · Do not overload the link. Up to 32 devices may be connected on a serial link. Terminate the link by installing a termination plug in the output socket of the last fixture. The termination plug, which is a male XLR plug with a 120 ohm, 0. 25 watt resistor soldered between pins 2 and 3, "soaks up" the control signal so it does not reflect and cause interference. · Use a phase-reversing cable to connect older Martin fixtures with reversed polarity sockets (pin 3 cold). 12 Controller operation Atomic 3000 user manual DMX CONTROL MODES The DMX control options are selected on the Mode DIP switch. 1-channel DMX mode allows you to strobe from 0 flashes per second to the maximum flash rate and trigger the blinder effect from the controller. Intensity is maximum in 1-channel DMX mode. The maximum intensity can be reduced by selecting low power mode as described on page 9. DU R A T I O N Flash duration can be set from 0 to 650 ms on 50 Hz power supplies, or 0 to 530 ms on 60 Hz power supplies, on channel 2 in the 3- and 4-channel DMX modes. Flash duration is fixed in 1-channel DMX mode. RA T E Flash rate can be set from 0 flashes per second to 25 flashes per second Hz on 50 Hz power supplies, or from 0 to 30 flashes per second on 60 Hz power supplies, on channel 3 in the 3- and 4-channel DMX modes. Flash rate is also controllable in 1-channel DMX mode. PR O G R A M M E D EFFECTS Six programmed effects are available on channel 4 in the 4-channel DMX mode only. The effects may be altered using the intensity, duration, and rate controls. · · · · Ramp up: Light gradually increases in intensity, then blacks out. Ramp down: Light flashes to full intensity, then gradually fades. Ramp up-down: Light gradually increases and decreases. Random flash: Light flashes randomly with variable rate and intensity. Multiple units flash independently of each other. · · Lightning: The flashes simulate lightning. Spikes: The lamp remains dimly illuminated between flashes. Set flash intensity, duration, and rate as normal. BLINDER EFFECT The blinder effect, in which the light remains on for an extended period, is available in all DMX modes. In the 3- and 4-channel modes, the effect is achieved Atomic 3000 user manual Controller operation 15 whenever the combination of flash duration and rate prevents pauses between flashes. [. . . ] Remove the spent fuse from the holder and replace it with an identical 20 amp 6. 3 x 32 mm time-delay fuse. 3 Replace the fuse holder in the side plate. FIRMWARE UPDATES If you suspect that the firmware installed on your Atomic 3000 has become corrupted, please contact your Martin dealer for assistance. Atomic 3000 user manual Service 23 DMX PROTOCOLS 1-CHANNEL DMX Channel 1 Value 0-5 6 - 249 250 - 255 Percent 0-1 2 - 98 98 - 100 A MODE Function Blackout Flash rate, slow to fast Continuous "Blinder" effect 3 AND 4 CHANNEL Percent 0-1 2 - 100 0 - 100 DMX Function MODES Channel 1 Value 0-5 6 - 255 0 - 255 Flash intensity Blackout Minimum to maximum Flash duration 0 - 650 ms @ 50 Hz AC, or 0 - 530 ms @ 60 Hz AC Flash rate No flash (single flash with ch. 1) 0. 5 - 25 Hz @ 50 Hz AC, or 0. 6 - 30 Hz @ 60 Hz AC Special effects No effect Ramp up Ramp down Ramp up-down Random Lightning Spikes 2 3 0-5 6 - 255 0-1 2 - 100 Note: Enable channel 4 with Mode DIP switch no. 0-5 6 - 42 43 - 85 86 - 128 129 - 171 172 - 214 215 - 255 0-1 2 - 16 16 - 33 33 - 50 50 - 67 67 - 84 84 - 100 4 ATOMIC 3000 SPECIFICATIONS PHYSICAL B Size (without bracket): . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MARTIN ATOMIC 3000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MARTIN ATOMIC 3000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag