User manual MAXON LV AIRFLO M BULLETIN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXON LV AIRFLO M. We hope that this MAXON LV AIRFLO M user guide will be useful to you.

Lastmanuals help download the user guide MAXON LV AIRFLO M.


Mode d'emploi MAXON LV AIRFLO M
Download
Manual abstract: user guide MAXON LV AIRFLO MBULLETIN

Detailed instructions for use are in the User's Guide.

[. . . ] The entire burner assembly is mounted inside a process air duct directly in the air stream being heated. The air stream passes across the burner and through the mixing plates and is used as combustion air. [. . . ] For upstream process air temperature up to 315°C. LV-4D AIRFLO® burners have a ductile iron body and #310 stainless steel mixing plates for applications with outlet temperatures up to 815°C. For upstream process air temperature up to 540°C. LV-5D AIRFLO® burners complement their ductile iron bodies with Hastelloy-X mixing plates for use in applications with up to 930°C outlet temperature requirements. For upstream process air temperature up to 540°C. LV-5B AIRFLO® burners have an aluminum bronze body casting with Hastelloy-X mixing plates for use with applications requiring up to 930°C outlet temperatures. For upstream process air temperature up to 565°C. Typical burner data Fuel: natural gas at 15°C with 10. 9 kWh/Nm3 HHV - sg = 0. 6 [1] Combustion air: 15°C - 21% O2 - 50% humidity - sg = 1. 0 [1] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality. Burner size Maximum capacity per foot [2] Minimum capacity per foot [2] Natural gas differential pressure [3] Flame length [4] Pressure drop process air [5] kW kW mbar m mbar LV-NP1 175 9 10 0. 3 LV-3G 730 22 70 2 LV-4D 730 22 70 2 0. 5 - 6. 2 LV-5D 730 22 70 2 LV-5B 730 22 70 2 [1] sg (specific gravity) = relative density to air (density air = 1. 293 kg/Nm3) [2] Maximum and minimum capacities are highly dependent upon the application. Check "Specifications of LV AIRFLO burners" for more information. [3] Natural gas differential pressure at burner inlet at maximum stated burner capacity. The stated values are valid for burners with standard gas drillings. Refer to "Specifications of LV AIRFLO burners" for gas differential pressures to be used with alternative gas drillings. [4] Flame length at highest capacity and highest process air pressure drop across the burner when firing on fresh air. [. . . ] All rights reserved. Duct burners - LV AIRFLO® 4 - 21. 4 - 6 E - m - 11/10 Typical emissions MAXON Series LV AIRFLO® burners are especially designed to meet the high demands of most of the local standards on air quality of direct fired process air heating applications worldwide. If correctly used within the performance limits as described on page 4-21. 4-7, both CO and NOx will remain far below the limits as determined in most standards. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXON LV AIRFLO M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXON LV AIRFLO M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag