User manual MAXTOR CLC31024N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR CLC31024N. We hope that this MAXTOR CLC31024N user guide will be useful to you.

Lastmanuals help download the user guide MAXTOR CLC31024N.


Mode d'emploi MAXTOR CLC31024N
Download
Manual abstract: user guide MAXTOR CLC31024N

Detailed instructions for use are in the User's Guide.

[. . . ] Line scan rate is fixed and is determined by frequency of EXSYNC signal. Matrox Pulsar sending RS-422 EXPOSURE1 (PRIN), RS-422 EXPOSURE2 (EXSYNC) and RS-422 Reference clock (MCLK) signals to camera; the EXPOSURE1 and EXPOSURE2 signals control the exposure time and initiates line readout. Matrox Pulsar receiving RS-422 pixel clock (STROBE @ 15 MHz) and RS-422 VSYNC (LVAL) signals from camera; the LVAL signal indicates valid lines (pixels). [. . . ] The clock rate is 15 Mhz; the line rate is therefore 3. 5KHz. The line rate of the camera, and therefore the exposure time, can be modified in the DCF using Matrox Intellicam. Consult the Matrox Intellicam User Guide for more information. The virtual frame rate for the current settings of the DCF is 287µs x 512 = 146. 9µs = 6. 8Hz. In each virtual frame there are 512 active lines. The host buffer of the Matrox Pulsar can grab images of up to 2048 x 2048 (4MB) and the display buffer can grab images of up to 2048 x 1024 (2MB) The time between the rising edge of the EXPOSURE1 and EXPOSURE2 signals is the exposure time. In order to select the exposure time, the width and deployment time of each EXPOSURE 1 and EXPOSURE 2 must be set in Matrox Intellicam. T1 µ 287µs EXPOSURE 1 (PRIN) 286µs µ T2 200µs µ EXPOSURE 2 (EXSYNC) 534ns 68. 27µs µ HSYNC (LVAL) Line rate = 1 287µs = 3. 5 KHz Mode 2: Variable line scan rate · · · · PSG FPGA version 3. 01 or newer is required. Line rate is variable and is controlled by the external trigger signal. Virtual frame size for this DCF is 1024 x 1 x 512 Once it has received the external signal to trigger, the Matrox Pulsar sends the RS-422 EXPOSURE1 (PRIN) signal to the camera to initiate exposure. The Matrox Pulsar will send the RS-422 EXPOSURE2 (EXSYNC) signal to the camera following a delay that is equal to the desired exposure time. A short (variable) delay after receiving the EXPOSURE2 pulse, the camera sends the RS-422 LVAL signal to the Matrox Pulsar to indicate line readout (line valid). PUL-CID-041 2 Application Note: DALSA CL-C3-1024N Camera Interface Details (continued) Interfacing non-standard cameras to Matrox Pulsar June 11, 1997 The maximum possible delay between the EXPOSURE2 pulse and the LVAL pulse is calculated to be: EXSYNC to LVAL = 4µs + 11 MCLK pulses + 4 MCLK pulses + 400ns Maximum = 4µs + (11 x 66. 7ns) + (4 x 66. 7ns) + 400ns = 4µs + 0. 734µs + 0. 267µs + 400ns = 5. 4µs µ TTL external trigger EXPOSURE1 (PRIN) 534ns EXPOSURE2 (EXSYNC) µ 200µs variable delay HSYNC (LVAL) µ exposure time = 200µs - 534ns shift and readout 68. 27µs µ Cabling Requirements Mode 1: Fixed line scan rate · · PULSAR/DIG/MOD required for digital data, syncs and control signals in RS-422 format. The connections between the OS1 20-pin dual row connector of the camera and the 68-pin connector of the PULSAR/DIG/MOD are as follows: DALSA CL-C3-1024N (20-pin dual row connector - OS1) Pin name Pin no. AD7+ 1 AD7- 2 AD6+ 3 AD6- 4 AD5+ 5 AD5- 6 AD4+ 7 AD4- 8 AD3+ 9 AD3- 10 AD2+ 11 AD2- 12 AD1+ 13 AD1- 14 AD0+ 15 AD0- 16 (Pin-out continued) PULSAR/DIG/MOD (68-pin connector) Pin name Pin no. DATA7+ 10 DATA7- 44 DATA6+ 11 DATA6- 45 DATA5+ 13 DATA5- 47 DATA4+ 14 DATA4- 48 DATA3+ 15 DATA3- 49 DATA2+ 16 DATA2- 50 DATA1+ 19 DATA1- 53 DATA0+ 20 DATA0- 54 PUL-CID-041 3 Application Note: DALSA CL-C3-1024N Cabling Requirements Interfacing non-standard cameras to Matrox Pulsar June 11, 1997 17 18 19 20 CLKIN+ CLKIN- HSYNC+ HSYNC- 29 63 26 60 STROBE+ STROBE- LVAL+ LVAL- · The connections between the DB-25 connector on the rear panel of the camera and the 68-pin connector of the PULSAR/DIG/MOD are as follows: DALSA CL-C3-1024N (DB-25 male connector) Pin name Pin no. [. . . ] Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273 Sales Offices: U. K. Sefton Park, Stoke Poges Buckinghamshire U. K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599 France Matrox France SARL 2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05 Germany Matrox GmbH Inselkammerstr. 8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743 Asia Pacific Matrox Asia Liaison Office Rm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR CLC31024N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR CLC31024N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag