User manual MAXTOR CLE12048A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR CLE12048A. We hope that this MAXTOR CLE12048A user guide will be useful to you.

Lastmanuals help download the user guide MAXTOR CLE12048A.


Mode d'emploi MAXTOR CLE12048A
Download
Manual abstract: user guide MAXTOR CLE12048A

Detailed instructions for use are in the User's Guide.

[. . . ] MCLK 6 MCLK 19 EXSYNC 17 EXSYNC 4 FOR/REV 5 FOR/REV 18 GROUND 7 GROUND 11 GROUND 20 GROUND 24 POWER SUPPLY GROUND POWER SUPPLY GROUND PULSAR/DIG/MOD (68-pin SCSI-2 connector) Pin name Pin no. CLKOUT+ 24 CLKOUT58 HSYNC+ 26 HSYNC60 CTRL1+ 23 CTRL157 GROUND 1 GROUND 12 GROUND 34 GROUND 35 GROUND 46 GROUND 68 NOTE: it is very important that all the GROUNDs of the camera be connected together to the POWER SUPPLY GROUND, which in turn must be connected to the GROUND of the Pulsar PUL-CID-012 2 Interfacing non-standard cameras to Matrox Pulsar DALSA CL-E1-2048A May 29, 1996 Application Note: · The connections between the DB-25 connector on the rear panel of the camera and the power supply are as follows: DALSA CL-E1-2048A (DB-25 male connector) Pin no. Pin name 8 +5V 9 +15V 12 -5V 13 +5V 21 +15V 22 -5V 23 -15V POWER SUPPLY +5V +15V -5V -15V Mode 2: Variable line scan rate · · IMG-7W2-TO-5BNC cable required for TTL external trigger source and PULSAR/DIG/MOD required for digital data, syncs and control signals in RS-422 format The connections between the 20-pin dual row connector (labeled OS1) of the camera and the 68-pin SCSI-2 connector of the PULSAR/DIG/MOD are as in Mode 1: fixed line scan rate with the exception of the following: DALSA CL-E1-2048A (20-pin dual row connector - OS1) Pin name Pin no. [. . . ] Consult the Matrox Intellicam User Guide for more information The virtual frame rate for the current settings of the DCF is 6. 88Hz. In each virtual frame there are 484 lines, 480 of which are active. Both the number of active video lines and the number of blanking lines can be altered by using Matrox Intellicam to modify the DCF; the virtual frame rate will be altered accordingly. The number of blanking lines can be reduced to no less than 1. The host buffer of the Matrox Pulsar can grab images of up to 2048 x 2048 (4MB) and the display buffer can grab images of up to 2048 x 1024 (2MB) Mode 2: Variable line scan rate · · · · · · PSG FPGA version 3. 01 or newer is required The line rate is variable and is controlled by the external trigger signal; the exposure time is inversely proportional to the line rate Once it has received the external signal to trigger, the Pulsar sends the RS-422 EXPOSURE2 (EXSYNC) signal to the camera. The camera awaits the rising edge of the signal; a short (variable) delay thereafter, the camera sends the RS-422 LVAL signal to the Pulsar to initiate line readout. The LVAL signal is high for the period during which a line of data is being read out Trigger rate can vary between 0Hz and 0. 68Khz Virtual frame size is 2048 x 480, with 4 lines of vertical blanking; therefore an effective 480 lines out of every 484 lines are acquired With an optional LCD electronic shutter, the exposure time can be controlled independently of the external trigger signal and is set in the DCF at the hardware register level. A hardware register editor is provided by running Intellicam with the -hwreg option (specifically by running INTELCAM -hwreg). An additional menu item, "HW REGISTER EDITOR", appears on the main menu screen. The following registers are used to define exposure timings: CTRL_SET1CNTL CTRL_SET1CNTH CTRL_T1STARTL CTRL_T1STARTH PUL-CID-012 4 Interfacing non-standard cameras to Matrox Pulsar DALSA CL-E1-2048A May 29, 1996 Application Note: These last are two 16-bit registers that have been split in two: the low byte and the high byte. To set these registers, note first that CTRL_SET1CNTL must be equal to CTRL_T1STARTL and that CTRL_SET1CNTH must be equal to CTRL_T1STARTH; this minimizes the delay between the time the Pulsar receives the external trigger signal and the time it sends the hsync or EXPOSURE1 signal to the camera. These values must be in pixels and must be set in hexadecimal; the value of each 16-bit register can vary between 0 (0000 in Hex) and 65 535 (FFFF in Hex). The default width of the EXPOSURE1 pulse for use of this camera with an optional LCD electronic shutter is 8192 pixels, which in hexadecimal is 2000; at a clock rate of 7. 159mhz, this corresponds to an exposure time of 1. 14ms. Here the low byte corresponds to 0H and the high byte to 20H. The registers are set in the following way: CTRL_SET1CNTL CTRL_SET1CNTH CTRL_T1STARTL CTRL_T1STARTH 0H 20H 0H 20H When computing the hardware registers, the following question may be asked: "Some registers have been manually edited. Answer "no" to this question and to all questions that follow. [. . . ] Dorval, Quebec, Canada H9P 2T4 Tel: (514) 685-7230 Fax: (514) 822-6273 Sales Offices: U. K. Sefton Park, Stoke Poges Buckinghamshire U. K. SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599 France Matrox France SARL 2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05 Germany Matrox GmbH Inselkammerstr. 8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743 Asia Pacific Matrox Asia Liaison Office Rm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR CLE12048A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR CLE12048A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag