User manual MAXTOR TM1010

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAXTOR TM1010. We hope that this MAXTOR TM1010 user guide will be useful to you.

Lastmanuals help download the user guide MAXTOR TM1010.


Mode d'emploi MAXTOR TM1010
Download
Manual abstract: user guide MAXTOR TM1010

Detailed instructions for use are in the User's Guide.

[. . . ] Application Note: PULNiX TM-1010 Camera Descriptions · · · · · · Interfacing non-standard cameras to Matrox Pulsar February 10, 1998 996 x 1016 x 10-bit. Digital (RS-422) or analog video output @ 15 fps. [. . . ] Camera sending RS-422 hsync (Line Data valid or LDV), RS-422 vsync (Frame Data Valid or FDV), and RS-422 pixel clock (CLK @ 20 MHz) signals to Matrox Pulsar. DCF used: TM1010AE. DCF Mode 1: Continuous mode (analog video output) Cabling Requirements · · · IMG-7W2-TO-1BNC cable required for video output of camera (single channel). Video input BNC of IMG-7W2-TO-1BNC cable should be connected to VIDEO OUT BNC connector of camera. The two switches on the rear of the camera must be set respectively to NRM (normal mode) and NSP (normal speed); the Shutter Control Switch on the rear of the camera must be set to 0 (no shutter). Mode 2: Continuous mode (digital video output) · · PULSAR/DIG/MOD required for digital data and syncs in RS-422 format The two switches on the rear of the camera must be set respectively to NRM (normal mode) and NSP (normal speed); the Shutter Control Switch on the rear of the camera must be set to 0 (no shutter). PUL-CID-045 2 Application Note: PULNiX TM-1010 Interfacing non-standard cameras to Matrox Pulsar February 10, 1998 Cabling Requirements (Continued) · The connections between the 68-pin connector of the PULSAR/DIG/MOD and the 31-pin connector of the camera are as follows: PULSAR/DIG/MOD (68-pin connector) Pin name Pin no. CLKIN+ 29 CLKIN- 63 HSYNC+ 26 HSYNC- 60 VSYNC+ 25 VSYNC- 59 GROUND 34 GROUND 12 DATA0+ 20 DATA0- 54 DATA1+ 19 DATA1- 53 DATA2+ 16 DATA2- 50 DATA3+ 15 DATA3- 49 DATA4+ 14 DATA4- 48 DATA5+ 13 DATA5- 47 DATA6+ 11 DATA6- 45 DATA7+ 10 DATA7- 44 DATA8+ 09 DATA8- 43 DATA9+ 08 DATA9- 42 PULNiX TM-1010 (31-pin DC connector) Pin name Pin no. CLK+ 01 CLK- 17 LDV+ 02 LDV- 18 FDV+ 03 FDV- 19 GND 04 GND 16 D0+ 06 D0- 22 D1+ 07 D1- 23 D2+ 08 D2- 24 D3+ 09 D3- 25 D4+ 10 D4- 26 D5+ 11 D5- 27 D6+ 12 D6- 28 D7+ 13 D7- 29 D8+ 14 D8- 30 D9+ 15 D9- 31 Mode 3: Asynchronous Reset (Pulse Width Control Mode) · · IMG-7W2-TO-5BNC cable required for TTL external trigger; PULSAR/DIG/MOD required for digital data and syncs in RS-422 format, and for TTL control signals. The two switches on the rear of the camera must be set respectively to ASY (asynchronous shutter mode) and NSP (normal speed); the Shutter Control Switch on the rear of the camera must be set to 9 (external pulse width control mode). PUL-CID-045 3 Application Note: PULNiX TM-1010 Cabling Requirements (Continued) · Interfacing non-standard cameras to Matrox Pulsar February 10, 1998 The connections between the 68-pin connector of the PULSAR/DIG/MOD and the 31-pin connector of the camera are as in continuous mode (digital video output) with the exception of the following: PULSAR/DIG/MOD (68-pin connector) Pin name TTL_EXPOSURE1 · Pin no. 66 PULNiX TM-1010 (31-pin DC connector) Pin name Pin no. VINIT 20 TTL external trigger source should be connected to the TTL Trigger Input of the IMG-7W2TO-5BNC cable. An RS-422 external trigger input may also be used once the following connections between the 68-pin connector of the PULSAR/DIG/MOD and the external trigger source are made: PULSAR/DIG/MOD (68-pin connector) Pin name Pin no. TRIGGER+ 27 TRIGGER61 External trigger source Pin name "RS-422 TRIGGER+" "RS-422 TRIGGER-" · · Use Matrox Intellicam in order to modify the DCF for an RS-422 external trigger input. Consult the Matrox Intellicam User Guide for more information The DCF(s) mentioned in this application note can be found on the MIL and MIL-Lite CD, or our FTP site (ftp. matrox. com). [. . . ] 1901, 19/F, Workington Tower, 78 Bonham Strand E. , Sheung Wan, Hong Kong. Tel: 852. 2877. 5387 Fax: 852. 2537. 9530 PUL-CID-045 4 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR TM1010

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR TM1010 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag