User manual MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T. We hope that this MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T user guide will be useful to you.

Lastmanuals help download the user guide MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T.


Mode d'emploi MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T
Download
Manual abstract: user guide MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T

Detailed instructions for use are in the User's Guide.

[. . . ] Series Nine GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. Model Numbers HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A . 0905 1 www. maytagwaterheaters. com PART NO. 184382-001 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. [. . . ] Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater. Consult your Maytag Service Center at 1-800-788889 or gas supplier if any such changes are planned. For proper venting in certain installations, a larger diameter vent pipe may be necessary. Consult your Maytag Customer Service Center or gas supplier to aid you in determining the 16 FIGURE 19. All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other draft hood. Vent pipes must be secured at each joint with sheet metal screws. There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer's clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement. plate is for the purpose of input adjustment. If the gas control valve is subjected to pressures exceeding 1/2 pound per square inch (3. 5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas. If the main gas line Shut-off serving all gas appliances is used, also turn "OFF" the gas at each appliance. Leave all gas appliances shut "OFF" until the water heater installation is complete. A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223. 1/NFPA 54 and your gas supplier concerning pipe size. There must be: · A readily accessible manual shut off valve in the gas supply line serving the water heater, and · A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve. · A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit. Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input. Failure to have required clearances between vent piping and combustible material will result in a fire hazard. Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation. Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive. Gas Piping Water heaters covered in this manual have been tested and approved for installation at elevations up to 7, 700 feet (2, 347 m) above sea level. [. . . ] 1 2 3 4 5 6 7 *8 9 10 11 12 13 14 15 16 *17 18 19 *20 21 22 23 24 25 26 27 28 Part Description Air Intake Screen Anode Rod Burner Assembly Burner Head** Burner Orifice** Burner Tube** Dip Tube/Inlet Tube Dip Tube/Inlet Tube Gasket Draft Hood Drain Valve Drain Valve Washer Flue Baffle Flue Restrictor Gas Control Valve Inner Door** Inner Door Gasket Instruction Manual Nipple w/Heat Traps Outer Door Outer Door Filler Piezo Igniter w/Bracket Pilot Assembly** Pipe Insulation Secondary Anode Rod T & P Insulation Temperature-Pressure Relief Valve Thermostat Shield (Optional) Viewport Assembly HRN4930T 66001503 66001591 66001585 66001494 66001538 66001593 66001518 66001812 66001502 66001016 66001021 66001501 66001187 66001504 66001595 66001500 184382-001 66001705 66001506 NA 66001507 66001550 66001755 66001514 66001709 66001079 66001667 66001509 HRP4930T 66001503 66001591 66001587 66001511 66001515 66001594 66001518 66001812 66001502 66001016 66001021 66001501 66001187 66001576 66001595 66001500 184382-001 66001705 66001506 NA 66001507 66001516 66001755 66001514 66001709 66001079 66001667 66001509 Model Numbers HRN4940S 66001503 66001251 66001491 66001494 66001538 66001495 66001596 66001812 66001502 66001016 66001021 66001522 66001187 66001504 66001498 66001500 184382-001 66001705 66001506 NA 66001507 66001547 66001755 66001514 66001709 66001079 66001667 66001509 HRP4940S 66001503 66001157 66001557 66001568 66001515 66001521 66001596 66001812 66001502 66001016 66001021 66001522 66001187 66001505 66001498 66001500 184382-001 66001705 66001506 NA 66001507 66001516 66001755 66001514 66001709 66001079 66001667 66001509 HRN4940T 66001503 66001020 66001558 66001494 66001538 66001496 66001544 66001812 66001502 66001016 66001021 66001589 66001187 66001504 66001499 66001500 184382-001 66001705 66001506 NA 66001507 66001547 66001755 66001514 66001709 66001079 66001667 66001509 HRP4940T 66001503 66001020 66001559 66001511 66001515 66001497 66001544 66001812 66001502 66001016 66001021 66001589 66001187 66001505 66001499 66001500 184382-001 66001705 66001506 NA 66001507 66001519 66001755 66001514 66001709 66001079 66001667 66001509 * Not Shown. Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Be sure to provide all pertinent facts when you call or visit. THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HRN4930T HRP4930T HRN4940S HRP4940S HRN4940T HRP4940T HRN4950S HRP4950S HRN4950T HRP4950T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag