User manual MAYTAG HV650HBVITCGA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MAYTAG HV650HBVITCGA. We hope that this MAYTAG HV650HBVITCGA user guide will be useful to you.

Lastmanuals help download the user guide MAYTAG HV650HBVITCGA.


Mode d'emploi MAYTAG HV650HBVITCGA
Download
Manual abstract: user guide MAYTAG HV650HBVITCGA

Detailed instructions for use are in the User's Guide.

[. . . ] Series Six POWER VENT GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers HV640YBVITCGA HV650YBVITCGA HV640HBVITCGA HV650HBVITCGA CANADIAN MANUAL · · · · · · Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A. 1005 www. maytagwaterheaters. com 1 PART NO. 185376-000 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. [. . . ] This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48. 8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2. 4 m). One 45° elbow is approximately equal to 4 feet (1. 2 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. 50, 000 BTU Units: For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12. 2 m). This does not include the supplied Vent Termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 3" Venting, the maximum equivalent feet of pipe allowed is 120 feet (36. 6 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 3" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). One 45° elbow is approximately equal to 2. 5 feet (0. 8 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. For 4" Venting, the maximum equivalent feet of pipe allowed is 160 feet (48. 8 m). This does not include the Vent Termination (supplied locally) for the water heater. For the 4" venting, one 90° elbow is approximately equal to 8 feet (2. 4 m). [. . . ] Water temperature sensor is either open or short circuited. Unit shuts down and in lockout. ABC ABC ABC Unit shuts down. ABC Unit shuts down and in lockout. TROUBLESHOOTING GUIDELINES These guidelines should be used by a qualified Maytag Customer Service Center Agent. Call the Maytag Customer Service Center at 1-800-788-8899 for assistance. Inform the associate that this is a "Flammable Vapor Ignition Resistant" Product. 30 REPAIR PARTS LIST MAYTAG GAS WATER HEATER MODEL NO'S 40 Gallon Natural Gas 50 Gallon Natural Gas 40 Gallon Propane (L. P. ) 50 Gallon Propane (L. P. ) HV640YBVITCGA HV650YBVITCGA HV640HBVITCGA HV650HBVITCGA BURNER ASSEMBLY OUTER DOOR (ALTERNATE) 1 Part Description HV640YBVIT Burner Assembly TBD Burner Head 66001494 Burner Orifice TBD Burner Tube TBD HSI Ignition Assembly TBD Inner Door 66001499 Inner Door Gasket 66001500 Flue Baffle TBD Flue Restrictor 66001513 Blower Assembly TBD Air Intake Screen - Base Pan 66001503 Inlet Tube 66001646 Gas Control Valve TBD Drain Valve 66001016 Drain Valve Washer 66001021 Outer Door TBD Anode Rod TBD Temperature-Pressure Relief Valve 66001079 Viewport Assembly 66001509 20" Dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HV650HBVITCGA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HV650HBVITCGA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag