User manual MCCULLOCH FG5700A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MCCULLOCH FG5700A. We hope that this MCCULLOCH FG5700A user guide will be useful to you.

Lastmanuals help download the user guide MCCULLOCH FG5700A.


Mode d'emploi MCCULLOCH FG5700A
Download
Manual abstract: user guide MCCULLOCH FG5700A

Detailed instructions for use are in the User's Guide.

[. . . ] PLEASE READ For your own safety please read this manual before attempting to operate your new unit. Failure to follow instructions can result in serious personal injury. Spend a few moments to familiarize yourself with your generator before each use. Dear Customer, Thank you for purchasing a McCulloch product. [. . . ] We recommend unleaded gasoline because it produces fewer engine and spark plug deposits and extends exhaust system life. Occasionally you may hear light "spark knock" or pinging" (metallic rapping noise) while operating under heavy loads. If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. G RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly. NOTE: Do not allow the starter to snap back against the engine. When the switch level move to ON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the lever to OFF after stopping the engine. 6-1B) N CHOKE LEVER (B) G The choke is used to provide an enriched fuel mixture when starting a cold eingine. it can pulled and pushed by operL ating the choke lever manually. Pull the lever out toward CLOSED to enrich the mixture. 6-1C) I OIL ALERT SYSTEM S The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. H Before the oil level in the crankcase can fall below a safe limit, the oil alert system will automatically shut down the engine (the engine switch will remain in the ON position). Circuit Breaker The circuit breaker (A) will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle. If the circuit breaker is switched OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again. 6-2A) Ground Terminal The generator ground terminal (B) is connected to the frame of the generater, the metal non-current carrying parts of the generator, and the ground terminals of each receptacle. 6-2B) Connections to a Building's Electrical System Connections for standby power to a building's electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes. Improper connections to a building's electrical system can allow electrical current from the generator to backfeed into the utility lines. Such backfeed may electrocute utility company workers or others who contact the lines during a power outage. Improper connections to a building's electrical system can allow electrical current from the utility company to backfeed into the generator. When utility power is restored, the generator may explode, burn, or cause fires in the building's electrical system. In some areas, generators are required by law to be registered with local utility companies. [. . . ] An improperly tightened spark plug can become very hot and could damage the engine. E Never use spark plugs which have an improper heat range. AC CIRCUIT BREAKER SERVICE G If AC circuit breakers require replacement they must be replaced with a circuit breakers having identical ratings and performance characteristics. Keep the generator level to prevent fuel spillage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MCCULLOCH FG5700A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MCCULLOCH FG5700A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag