User manual MEDISANA MEDITOUCH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MEDISANA MEDITOUCH. We hope that this MEDISANA MEDITOUCH user guide will be useful to you.

Lastmanuals help download the user guide MEDISANA MEDITOUCH.


Mode d'emploi MEDISANA MEDITOUCH
Download
Manual abstract: user guide MEDISANA MEDITOUCH

Detailed instructions for use are in the User's Guide.

[. . . ] Blood glucose monitor MediTouch Instruction Manual Please read carefully. Art. 79026 Contents 1 Explanation of symbols . . . . . . . . . . . . . . . . 1 2 Safety information . . . . . . . . . . . . . . . . . . . . . . . . . 2. 1 Always observe the following points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · If or remain in the display and no other entries are made then the test results will be saved in the memory with or . Press the container so that a tiny droplet forms on the tip of the container. Place the drop onto the blood sample area on the end of the test strip. Do not get any control solution on the top of the test strip. 2. Press twice, "CtL" appears in the display. Press , to confirm. 15 5 Operating Before you remove the test strip, check whether the result lies within the range indicated on the test strips container. 8. When a sufficient amount of control solution has been absorbed by the reaction cell you will hear a beep. The monitor starts a countdown of approx. 5 seconds which is shown in the display. In the display, a test result appears. 10. Once you have compared the test reading with the reading indicated on the test strip container, remove the test strip and throw it away. 16 5 Operating 5. 1. 3 Evaluating the control test result The permissible range for the control solution reading is indicated on the label of the test strip container. Your test result must lie within the range indicated. Make sure that you compare the test result with the correct range. If the control test result lies within the range indicated on the test strip container, then the monitor and the test strips are working accurately. If the control test result does not lie within the range indicated on the test strip container, then the following options will be displayed to rectify the problem: Cause Has the test strip been lying around open for a long time?Was the test strip container properly closed?Remedy Repeat the test with a test strip that has been stored correctly. Repeat the test as described in section 5. 1. 2. If problems persist, get in touch with the service centre. Use new control solution to check the performance of the monitor. Repeat the control test using strips and solution that have been stored correctly. Repeat the test as described in section 5. 1. 2. [. . . ] To disinfect the protective cap, soak it in 70 % - 75 % cleaning alcohol for 10 minutes once a week after cleaning. Leave the cap to dry thoroughly after disinfecting. 36 7 Miscellaneous 7. 3 Technical specifications Name and model Measuring methods Measuring range Measuring time Memory Calibration Operating conditions Storage/transport conditions Blood sample volumes Sample material Haemotocrit value (Htc) Power supply Battery operation Automatic switch-off Dimensions (display) Dimensions (base unit) L x W x H Weight Article number EAN number MEDISANA MediTouch blood glucose monitor Electrochemical biosensor technology 1. 1 - 33. 3 mmol/L approx. 5 seconds 360 test results with time and date Plasma Temperature 10°C ­ 40°C (50°F ­ 104°F), maximum relative humidity 90% Temperature 2°C ­ 30°C (35. 6°F - 86°F), maximum relative humidity 90% 0, 6 ÌL Fresh blood from the finger tip, palm of the hand or arm (capillary whole blood) 30 ­ 55 % 1 x 3 V CR2032 lithium battery For approx. 40 g without battery 79026 40 15588 79026 3 In accordance with our policy of continual product improvement, we reserve the right to make technical and visual changes without notice. 37 7 Miscellaneous Electromagnetic compatibility: The device complies with the EN 60601-1-2 standard for electromagnetic compatibility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MEDISANA MEDITOUCH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MEDISANA MEDITOUCH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag