[. . . ] OPERATING MANUAL METO-FER® AUTOMATION AG COMPACT GRIPPER TYPE KZP 12 KZP 20 KZP 25 KZP 32 KZP 50 SERIES FROM 2-16 1. 1. 1 PRODUCT DESCRIPTION Introduction 1. 1. 1. Utilization The compact grippers KZP (KZP. . . D) are able to execute grip movements in any position. [. . . ] Performance Characteristics Type KZP 12 KZP 20 KZP 25 KZP 32 KZP 50 Clamping force at 72. 5PSI (5 Bar) 4 lb. ( 19 N) ( 30 N) ( 48 N) ( 85 N) (220 N) Air consumption for each double stroke at 72. 5 PSI (5 Bar) . 0002 scf (0. 004 NL) . 0005 scf (0. 014 NL) . 0010 scf (0. 027 NL) . 0025 scf (0. 072 NL) . 0079 scf (0. 224 NL) NL: Normal Liter 1. 2. 3 Operating Source 40mm filtered, unoiled or oiled air (dew point 6oC) Operating pressure Pmin 3 bar Pmax 8 bar 1. 2. 4 Connections Air connections 1. 2. 5 Environment Temperature Relative humidity Purity of the environment air 50oF to 122oF (+ 10oC to + 50oC) 95% (without condensation of water) regular working place atmosphere M5 (see sheet 6) 2 OPERATING MANUAL (KZP) 1. 3 1. 3. 1 Features Standard Features The compact gripper KZP (KZP. . . D) includes a sensor bracket for checking the open and closed positions. It is possible to add this sensor bracket later on by ordering KZP. . . Q. The inductive proximity sensors are not included. 1. 3. 2 Special Equipment The compact grippers KZP (KZP. . . D) can be equipped with proximity switches (see Meto-Fer® Electronic Catalog Page 15) so you will be able to check open and closed positions. Gripper KZP 12 D KZP 20 D KZP 25 D KZP 32 D KZP 50 D 2. SAFETY REGULATIONS Inductive Proximity Switches IM-004-. . . -. . . IM-006-. . . -. . . 2. 1 In general See chapters 1. 1. 1 1. 1. 2 1. 1. 3 2. 2 Specifically Do not make any changes or modifications to the unit (voids warranty). 3. CONSTRUCTION AND FUNCTION To check the open and closed positions, the compact gripper can be equipped inductive proximity switches. The stroke (clamp) can be adjusted by turning of with 3 the set screw (see list). OPERATING MANUAL (KZP) Compact Gripper Type KZP 12 KZP 20, 25 KZP 32, 50 4. 4. 1 INITIAL OPERATION Compressed Air Position No. of Set Screw 207 208 209 Remove the safety caps from the air connections. In order to regulate the velocity of the movement, we recommend our flow controls DV-M5 (see sheet 5. 021). 5. 1 MAINTENANCE Introduction The compact gripper unit does not require any special maintenance procedure Never use any type of solvents in order to clean the unit. 5. 2 Air Supply The mini linear unit is equipped with oil-free seals and can be operated with dry and non-oiled compressed air. If oiled compressed air is used, we recommend: Airpress compound SAE 5 (Klueber Order No. [. . . ] Housing Pos. 6 Pos. 1 Pos. 1 Pos. 1 Pos. 1 Cylinder Screw Pos. 205 Pos. 206 Pos. 206 Pos. 207 Pos. 207 Piston Pos. 7 Pos. 2 Pos. 2 Pos. 2 Pos. 2 Set Screw Pos. 11 Pos. 10 Pos. 10 Pos. 13 Pos. 13 Type KZP 12 KZP 20 KZP 25 KZP 32 KZP 50 7. 7. 1 SPARE PARTS LIST Spare Parts When ordering spare parts, the type and serial number of the unit must be supplied. Seal Kit Order Number 460. 100. 0302 Position Order Description Number 201 025. 100. 0320 O-Ring 202 025. 150. 0500 Piston Seal 203 025. 150. 0160 O-Ring Seal Kit Order Number 460. 100. 0304 Position Order Description Number Type Quantity 1 Piece 1 Piece 1 Piece KZP 12 Type Quantity 6 KZP 20 201 202 203 025. 100. 0520 025. 150. 0550 025. 100. 0230 O-Ring Piston Seal O-Ring 1 Piece 1 Piece 1 Piece 7 OPERATING MANUAL (KZP) Type KZP 25 Seal Kit Order Number 460. 100. 0306 Position Order Description Number 201 025. 100. 0580 O-Ring 202 025. 150. 0600 Piston Seal 203 025. 100. 0270 O-Ring Seal Kit Order Number 460. 100. 0308 Position Order Description Number 201 025. 100. 0660 O-Ring 202 025. 150. 0650 Piston Seal 203 025. 100. 0310 O-Ring Seal Kit Order Number 460. 100. 0309 Position Order Description Number 201 025. 100. 0795 O-Ring 202 025. 150. 0700 Piston Seal 204 025. 100. 0420 O-Ring Quantity 1 Piece 1 Piece 1 Piece Type Quantity 1 Piece 1 Piece 1 Piece KZP 32 Type Quantity 1 Piece 1 Piece 1 Piece KZP 50 7. 2 Lubrication Grease for seals Staburag NBU 4 Atemp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE METO-FER KZP 12

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual METO-FER KZP 12 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag