User manual MIELE DA 362-75

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE DA 362-75. We hope that this MIELE DA 362-75 user guide will be useful to you.

Lastmanuals help download the user guide MIELE DA 362-75.


Mode d'emploi MIELE DA 362-75
Download

You may also download the following manuals related to this product:

   MIELE DA 362-75 (900 ko)

Manual abstract: user guide MIELE DA 362-75

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions Ventilation System DA 362-75 DA 362-110 To prevent accidents and machine damage, read these instructions before installation or use. UV M. -Nr. 06 191 500 Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the hood Operation Main power switch . 14 Cleaning and care Cleaning the casing . 20 After Sales Service Installation instructions Caring for the environment Electrical data Appliance dimensions Installation Air extraction mode . [. . . ] The indicators of the fan power scale show the programmed time: 1st indicator from the left = 20 hours 2nd indicator from the left = 30 hours 3rd indicator from the left = 40 hours 4th indicator from the left = 50 hours ^ Press the Delayed Shut Down and the grease filter buttons at the same time. The indicator for the grease filter and one of the fan power scale indicators will flash. ^ Use the joystick to select the desired time. Press it to the left for a shorter operating time, to the right for a longer operating time. ^ Store the selection by pressing the grease filter button. If the procedure is not stored within 4 minutes of programming the hood will automatically default to the "old" data. 14 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and can not be used to exhaust fumes. The charcoal filter timer is not preset. Before using the hood in recirculation mode, the charcoal filter timer must be programmed. ^ Press the joystick to the left to turn the fan off. ^ Use the joystick to select the desired time. Press it to the left for a shorter operating time, to the right for a longer operating time. ^ Press the Delayed Shut Down and charcoal filter buttons at the same time. The indicator for the charcoal filter and one of the fan power scale indicators will flash. ^ Store the selection by pressing the charcoal filter button. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. The indicators of the fan power scale show the programmed time: 1st indicator from the left = 120 hours 2nd indicator from the left= 180 hours 3rd indicator from the left = 240 hours 4th indicator from the left = infinite 15 Cleaning and care Stainless steel Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker. Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can also be used. Stainless steel colored controls These controls may become discolored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls. Cleaning the casing Warning: Never use abrasive cleansers, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ All external surfces and controls can be cleaned with warm water and liquid dish soap applied with a soft sponge. Do not use too much water when cleaning the controls. Water could penetrate into the electronics and cause damage. 16 Cleaning and care Grease filters The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). Cleaning the grease filters ^ Clean the filters: ­ by hand: use a scrub brush in warm water with a mild detergent. ­ in a dishwasher: place the filters vertically and diagonally in the lower basket. Make sure that the spray arm can rotate freely. [. . . ] At the same time counter the joystick with a wrench. 33 Installation Electrical connection Before connecting the appliance to power read the "Important Safety Instructions". ^ Before using the appliance remove the grease filters and remove the protective foil from the filter frame. Insert the grease filters back into place. 34 Air extraction Danger of toxic fumes!Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 362-75

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 362-75 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag