User manual MIELE DA403

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE DA403. We hope that this MIELE DA403 user guide will be useful to you.

Lastmanuals help download the user guide MIELE DA403.


Mode d'emploi MIELE DA403
Download
Manual abstract: user guide MIELE DA403

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions Ventilation System DA 403 To prevent accidents and machine damage, read these instructions before installation or use. UV M. -Nr. 06 473 940 Contents IMPORTANT SAFETY INSTRUCTIONS Functional description Guide to the appliance Operation Turning on the fan . 15 Cleaning and Care Cleaning the casing . 20 After Sales Service Installation instructions Structural support Electrical data Appliance dimensions Installation Installation accessories . [. . . ] ^ To deactivate the automatic switch back press the "­" button. ^ To save the setting press the Delay Shut down button. The number of flashing "­/+" indicators show the percentage of programmed hours that have been used. 1 indicator 2 indicators 3 indicators 4 indicators = = = = less than 25 % less than 50 % less than 75 % less than 100 % This information will remain stored in memory in the event of a power failure. The charcoal filter indicator will light once the selected time has elapsed. The charcoal filter must then be replaced and the charcoal filter timer reset. ^ To do this, press the charcoal filter button for about 3 seconds. The indicator will go out. 14 Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. ­ A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. ­ A time of 20 hours should also be programmed if the kitchen is only used occasionally to prevent grease which has accumulated over a long period of time from hardening on the filters making cleaning more difficult. Reprogramming the grease filter timer ^ Store the selection by pressing the grease filter button. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. The lit indicator shows the programmed time: 1st indicator from the left 2nd indicator from the left 3rd indicator from the left 4th indicator from the left = = = = 20 hours 30 hours 40 hours 50 hours ^ Use the "­/+" button to select the desired time. ^ Press the On/Off button to turn off the fan. ^ Press the Delayed Shut Down and grease filter buttons at the same time. The indicator for the grease filter and one of the "­/+" indicators will flash. 15 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and cannot be used to exhaust fumes. The charcoal filter timer is not preset. Before using the hood in recirculation mode, the charcoal filter timer must be programmed. The lit indicator shows the programmed time: 1st indicator from the left 2nd indicator from the left 3rd indicator from the left 4th indicator from the left = = = = 20 hours 30 hours 40 hours 50 hours ^ Use the "­/+" button to select the desired time. ^ Turn off the fan using the On/Off button. ^ Store the selection by pressing the charcoal filter button. ^ Press the Delayed Shut Down and charcoal filter buttons at the same time. The indicator for the charcoal filter and one of the "­/+" indicators will flash. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. 16 Cleaning and Care Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet, or manually "tripping" the circuit breaker. Stainless steel Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can be applied. Controls These controls may become discolored or damaged if not cleaned regularly. [. . . ] Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. The exhaust gases extracted by the hood should be vented outside of the building only. Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. Please read and follow the "Important Safety Instructions" to reduce the risk of personal injury. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA403

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA403 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag