[. . . ] The stopcock for the steam oven water inlet must be located so that it is easily accessible after the appliance has been built in. To ensure that the waste water is pumped away completely, the mains drainage outlet point should not be positioned higher than the drain hose outlet position on the steam oven. The temperature of the water being drained is approx. The hoses and mains connection cable must be fitted in such a way that the appliance can be easily taken out of the housing unit by a service technician should repair work ever be necessary.
This steam oven must only be installed in a suitable tall housing unit. [. . . ] Important UK: Do not position the isolator behind the appliance!c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!h Drain hose
Important: The top end of the drain hose i must not be higher than 500 mm where it connects to the odour trap.
11
Appliance and building-in dimensions
DG 4064 L and AB 45-7 in 450 mm tall housing unit
45
2 200 cm
595
05
55
448-452
324
b fg
56
8 0-56
593-595
378
385
55
270
5
95
05
55 8
54
c d e
h
5
56 60-
1 22
59
54
500
4
59 22
5
i
12
700
a
552
63
65
Appliance and building-in dimensions
a Cut-out in the housing unit for feeding the water inlet and outlet hoses through b Isolator switch position. Important UK: Do not position the isolator behind the appliance!c Stopcock (cold water connection) d Water inlet connection with safety valve e Water inlet hose f Second separate siphon g Do not connect the drain hose here!h Drain hose
Important: The top end of the drain hose i must not be higher than 500 mm where it connects to the odour trap.
13
Installation
Building in and connecting to services
^ Before connecting the appliance to the mains supply you must disconnect the electricity supply to the isolator switch. ^ Connect the mains connection cable to the isolator switch in accordance with current local and national safety regulations. ^ Feed the water inlet and drainage hoses through the cut-out a in the housing unit. ^ Push the appliance into the recess as far as it will go, making sure that the mains connection cable and the water inlet and drain hoses do not get trapped or damaged when doing so. After aligning the appliance, it must be secured against slippage. ^ Secure the appliance using screws j supplied, as shown in the diagrams. ^ Switch the electricity supply back on again. ^ Connect the appliance to the water supply and drainage outlet. ^ Using the Operating Instructions as a guide, check all oven functions are working correctly. Before using for the first time, check all hose connections for leaks. DG 4064
DG 4064 L
14
Electrical connection
All electrical work should be carried out by a suitably qualified and competent person, in strict accordance with current local and national safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held liable for unauthorised work. Ensure power is not supplied to the appliance until after installation or repair work has been carried out. The appliance must only be operated when built-in. This is to ensure that all electrical parts are shielded. Do not connect the appliance to the mains electricity supply by an extension lead. [. . . ] If necessary a pressure reducing valve must be fitted. The water connection must be fitted so that the stopcock is easily accessible (e. g. The person installing the appliance is responsible for ensuring its correct operation. If a water softener is already installed in the building, the electrical conductivity of the water must be maintained. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DG 4064
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.