User manual MIELE KM402 INSTALLATION MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE KM402. We hope that this MIELE KM402 user guide will be useful to you.

Lastmanuals help download the user guide MIELE KM402.


Mode d'emploi MIELE KM402
Download

You may also download the following manuals related to this product:

   MIELE KM402 (417 ko)
   MIELE KM402 (329 ko)

Manual abstract: user guide MIELE KM402INSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] 9 Laying out the support bars and clamps. 14 3 IMPORTANT SAFETY INSTRUCTIONS Note to the installer: Please leave this instruction book with the consumer for the local electrical inspector's use. Installation The minimum distances given in these Installation Instructions must be observed in order to ensure safe operation. [. . . ] The minimum safety distance between the KM 410 / KM 411 and the bottom of a venting hood should be no less than 26" (650 mm). If more than one appliance is installed beneath a hood and they have different minimum safety distances, the greater distance should be followed. Keep this instruction book in a safe place and pass it on to any future owner. 5 Appliance dimensions KM 400 / KM 408-1 a Clamps b Please allow an additional 3/4" (18 mm) depth below the cooktop for clearance of the power cord. 6 Appliance dimensions KM 402 / KM 403 a Clamps 7 Appliance dimensions KM 410 / KM 411 a Clamps 8 Installation Cutting out the countertop Installing one or multiple appliances: Cut out the countertop using the dimensions listed in the following table. Number of cooktops 1 2 3 4 5 All Miele combisets have the same length and width. Make sure that there is enough room beneath the countertop to allow for the depth of the various appliances. When installing a KM 402 / KM 403 or KM 410 / KM 411 remember to allow clearance for the drain valve that will be located in the cabinet beneath the appliances. 6 7 Cut out width Dimension "B" 10 13/16" 22 1/8" 33 7/16" 44 13/16 56 1/8" 67 1/2" 78 13/16" (274 mm) (562 mm) (850 mm) (1138 mm) (1426 mm) (1714 mm) (2002 mm) The tolerance for each dimension is 1 /16" (1 mm). The following safety distances must be maintained: ­ Between the cooktop and rear wall: 2" (50 mm). ­ Between the cooktop and side wall or cabinet: KM 400 = 2" (50 mm) KM 402 / 403= 2" (50 mm) KM 408-1 = 2" (50 mm) KM 410 / 411 =10" (250 mm) Refer to section "Important Safety Instructions" for further information. When installing more than one combiset cooktop, a support bar must be installed between the appliances. Install the support bars as shown on the following page before setting the appliances into the countertop. 9 Installation Laying out the support bars and clamps a Clamps b Support bars This illustration shows the layout for 3 combisets, their respective support bars, b, and the 14 spring clamps, a, required for correct installation. If more than 3 combisets are being installed, add an additional 11 3/8" (288 mm) to the overall width of the cut out for each extra combiset, or use the table on the preceding page. c Slight gap between support bar and countertop. 10 Installation Securing the support bars Securing the spring clamps d c Wood or Corian countertops ^ Arrange the bars, b, as shown in the illustration ^ Drill 1/16" (1. 5 mm) pilot holes through the brackets and secure them using the supplied screws. ^ Fill the gap, c, between the bars and the countertop using the supplied silicon sealant. Wood or Corian countertops ^ Place the spring clamps, a, as shown in the illustration. ^ Drill two 1/16" (1. 5 mm) pilot holes for each clamp and secure using the supplied screws. Granite countertops For granite countertops, the support bars, b, can be secured using double-sided construction tape. Do not allow the bars to "float", they must be securely fastened. [. . . ] The manufacturer cannot be held responsible for damages caused by the lack, or inadequacy of an, effective grounding system. Power supply: ­ 240 V, 60 Hz, 15 A fuse rating or ­ 208 V, 60 Hz, 15 A fuse rating The oven is equipped with a power cord consisting of 3 leads. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE KM402

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE KM402 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag