User manual MIELE KM451 INSTALLATION MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MIELE KM451. We hope that this MIELE KM451 user guide will be useful to you.

Lastmanuals help download the user guide MIELE KM451.


Mode d'emploi MIELE KM451
Download

You may also download the following manuals related to this product:

   MIELE KM451 (345 ko)

Manual abstract: user guide MIELE KM451INSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] 9 3 IMPORTANT SAFETY INSTRUCTIONS Note to the installer: Please leave this instruction book with the consumer for the local electrical inspector's use. The minimum distances given in these Installation Instructions must be observed in order to ensure safe operation. [. . . ] If cutlery inserts are placed in the drawer, they must be heat resistant. The cooktop must not be installed over a dishwasher, washer, dryer, refrigerator or freezer. The high temperatures radiating downwards from this type of cooktop could damage these appliances. Make sure that the power cord to the cooktop does not come in contact with any mechanical parts once the cooktop has been installed. Safety distance above the appliance As a general rule there must be a safety distance of at least 30" (760 mm), b, between the appliance and any flammable objects above it, e. g. cabinetry, venting hood or utensil rail. The minimum distance of combustible surfaces located above and to the side of the cooktop, c, is 18" (457 mm). If the manufacturer of these items states a different figure, follow that manufacturer's recommendation. If more than one appliance is installed beneath a venting hood, e. g. an electric cooktop and a gas wok cooktop, and they have different minimum safety distances to the hood, select the larger safety distance of the two. 5 Appliance dimensions and countertop cut-out KM 451 5 (8m16" m) 24 (58 16" mm ) 20 16 ) m (514m 4 " (930 36 5 10 mm) 16 " 16 " (8m 4 m) 16 3 " m) max. R4 2 " . 50) in (m 11 16" ) 19 0mm c m (83 b 31 (9 6 16" 16 mm ) (5 0 (m 2" ) 50 in. b a Spring clips b There must be at least 3 1/4" (83 mm) of usable depth to the right hand side of the cut out. ^ Seal the cut surfaces with a suitable sealant to avoid swelling caused by moisture. Be sure the materials used are heat resistant. If, during installation, the seal around the frame does not sit flush with the countertop or the corners, the corner radius max. [. . . ] To reduce the risk of electric shock, make sure that the appliance is properly grounded after installation. WARNING: THIS APPLIANCE MUST BE GROUNDED The appliance is provided with 3 leads; L1 (black), L2 (red) and GND (green). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE KM451

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE KM451 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag