User manual MITSUBISHI PLA-A-BA4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MITSUBISHI PLA-A-BA4. We hope that this MITSUBISHI PLA-A-BA4 user guide will be useful to you.

Lastmanuals help download the user guide MITSUBISHI PLA-A-BA4.


Mode d'emploi MITSUBISHI PLA-A-BA4
Download
Manual abstract: user guide MITSUBISHI PLA-A-BA4

Detailed instructions for use are in the User's Guide.

[. . . ] For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. Before installing the unit, make sure you read all the "Safety Precautions". the "Safety Precautions" provide very important points regarding safety. Please report to or take consent by the supply authority before connection to the system. [. . . ] This is used only to decide direction conclusively. Attention: Be careful not to set wrong air conditioner. Press Fan Speed button and Filter button for more than 2 seconds simultaneously and it becomes the fixed airflow direction mode after a while. The fixed setting completed (Go to step [4]. Only the air from the selected outlet blows downward. Air from the wrong outlet blows downward. The numbers of the air conditioner (refrigerant address No. It is also canceled by pressing Fan Speed button and Filter button for more than seconds simultaneously. Do not operate wired remote controller for 30 seconds after the "Fixed airflow direction mode" is canceled. Each air conditioner has its own refrigerant address No. Is found by its airflow direction with the unit No. The refrigerant address does not have further unit No. Check from refrigerant address 00 at first. * By changing refrigerant address, unit No. When "Err" is displayed, refrigerant address does not heve further "unit No. Change to the next "refrigerant address No. To clear fixed setting To clear all fixed setting(reset to factory default), press check button(clear botton) for wired more than 3 seconds in fixed airflow direction mode. Run the ventilator together with the indoor unit. Running the ventilator independently is not available. Timer functions are different by each remote controller. For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller. Following indication shows that the filter needs cleaning. [. . . ] (*) The operation lamp near the receiver for the IR wireless remote controller on the indoor unit is blinking. If nothing appears even after the batteries are replaced, make sure that the batteries are installed in the correct directions (+, ­). The self diagnosis function has operated to protect the air conditioner. Do not attempt to repair this equipment by yourself. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI PLA-A-BA4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI PLA-A-BA4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag