User manual MOFFAT MGH620B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual MOFFAT MGH620B. We hope that this MOFFAT MGH620B user guide will be useful to you.

Lastmanuals help download the user guide MOFFAT MGH620B.


Mode d'emploi MOFFAT MGH620B
Download
Manual abstract: user guide MOFFAT MGH620B

Detailed instructions for use are in the User's Guide.

[. . . ] GAS HOB MGH 620 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance Keep this instruction book for future reference and ensure it is passed on to any new owner. 3 1 2 3 4 1. Hob Top Rapid Burner Semi-rapid Burners Auxiliary Burner Control knobs Electric Ignition Push Button 6 5 These instructions are only valid for : GB Important Safety Information You MUST read these warnings carefully before installing or using the oven. If you need assistance, contact our Customer Care Department on 08705 950950 Installation This hob must be installed by qualified personnel, according to the manufacturer's instructions and to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. [. . . ] * The guarantee is for the same period and to the same extent for labour and parts as exist in the new contry of use for this brand or range of products. * This guarantee relates to you and cannot be transferred to another user. * Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i. e. a normal household The electrical supply complies with the specification given in the rating label. * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 3 44 62 20 13 Germany Nürnberg +49 (0) 800 234 7378 Italy Pordenone +39 (0) 800117511 Sweden Stockholm +46 (0) 20 78 77 50 UK Slough +44 (0) 1753 219898 Instructions for the Installer This hob must be installed by qualified personnel to the relevant British Standards. Any gas installation must be carried out by a registered CORGI installer. The manufacturer will not accept liability, should the above instructions or any of the other safety instructions incorporated in this book be ignored. Engineers technical data Overall dimensions Width: 580 mm. Cut out dimensions Width: Depth: 550 mm. 470 mm. Supply connections Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. Rear Left Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (rapid) Heat Input 3. 0 kW (10236 BTU/HR) 2. 8 kW L. P. G. (9554 BTU/HR) Rear Right Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR) APPLIANCE CLASS: 3 APPLIANCE CATEGORY: II 2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Burner Auxiliary Semi-rapid Rapid Dia. Tap By-pass 1/100 mm 28 32 40 Aeration adjustment none Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. [. . . ] Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red. Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath. A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely. FO 0390 Wiring Diagram L 1 A 0 2 3 220/240 4 B A. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MOFFAT MGH620B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual MOFFAT MGH620B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag