User manual NAPCO ACM1D DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO ACM1D. We hope that this NAPCO ACM1D user guide will be useful to you.

Lastmanuals help download the user guide NAPCO ACM1D.


Mode d'emploi NAPCO ACM1D
Download
Manual abstract: user guide NAPCO ACM1DDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Each GEM-ACM1D Module provides 1 door of access, expanded for a second controlled door by simply adding a Plug-In PCB, model no. The Gemini Security System Control Panel is made compatible with easy replacement of its standard EPROM with a GeminiAccess software enhancement upgrade. GeminiAccess provides controlled access to a door by releasing a mag or electric strike when a valid Prox card or Prox keyfob is presented to an HID or GEM-PX proximity reader. Access control is integrated with the burglary functions of the GEM-X255. [. . . ] And, the 2 prox readers controlled by each expanded GeminiAccess Module can be programmed to function independently on different doors, or together, controlling access for both sides of one door. Manufacturing great security products is all we do. It's that simple. TM PRELIMINARY SPECIFICATIONS: The GeminiAccess System supports HID standard 26 bit format and/or NAPCO Gemini Prox format. Recommended prox readers: · HID Prox Point Plus Model 6005B · NAPCO GEM-PX Prox Reader with Alarm Status LEDs The GEM-ACM1D also supports the use of any "Request to Exit" device and any UL 294 listed mag lock. GEM-PX Prox Reader with Alarm Status Indicators The unique GEM-PX Prox Reader includes LED status indicators for both the access and alarm system The LED's function as follows: · RED ­ Displays System Armed (on solid), system disarmed, (off) and system in alarm (blinking). · GREEN ­ Displays Ready to Arm (on solid), not ready (off). (Note: Alarm Status indication is a programmable option by Module and may be eliminated in undesirable instances, for example, where the reader is visible from outside the premises, etc. ) GEM-ACM1D Power Supply The GEM-ACM1D has an integral power supply which includes two primary linear regulators. The first regulator is used to power the panel, the readers and to recharge the battery. The panel and readers are supported with battery standby. The second regulator is used to supply up to 1. 5A 12VDC for the door locks, which provides enough current to support two 750mA electromagnetic locks. The Door Lock Power has an option to enable battery standby with a shunt connector placed across jumper JP3 (factory default). The battery is prevented from damage caused during extended power failures with a battery drop out circuit that disconnects the battery when there is no AC present and battery voltage drops to approximately 9VDC. When AC is restored, the battery is automatically re-connected and begins to recharge. The GEM-ACM1D tests the battery under load every 4 hours and when the RESET button is pressed. The low battery condition will only restore after it passes the active test. The duration of this test is 15 seconds. The separation of the door lock power from the rest of the system reduces the likelihood that turning off the power to the door lock coils will affect performance of the system. The use of linear versus switching regulators significantly reduces electrical noise that may hinder the sensitivity of proximity card readers. Fire System Integration GeminiAccess includes an "Emergency Free Access" zone for integration with a fire system. The output(s) from the fire alarm system must be wired so that if there is a fire alarm or AC failure of the fire alarm system, the "Emergency Free Access Zone" is either shorted or opened. (Before installing the access control system, be sure to consult with the authority having jurisdiction to be sure to comply with all local codes. ) SPECIFICATIONS Housing Dimensions: 11"x12 1/8"x3" (28x30. 8x7. 6cm) HxWxD GEM-X255 Current Draw: 5mA Operating Temperature: 0­49°C (32-120°F) Input Power: 16. 5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer Door Zone Loop Voltage: 10-13VDC Door Zone Loop Current: 2. 4mA with 2. 2K EOLR Door Zone Loop Resistance: 300 ohms maximum Combined Door Lock Power: D1 PWR (terminals 3+ and 4-) + D2 PWR (terminals 5+ and 6-) Voltage Rating: 12VDC Maximum Current: 1. 5A Battery Standby Time: JP3 not installed: Standby Time = 0* JP3 installed (factory default) Reader 1 PWR: READER 1 PWR (terminals 17+ and 18-) Voltage Rating: 12. 5VDC to 11. 7VDC with JP1 set to 12V (default). Maximum Current: 125mA Battery Standby Time: JP3 not installed and 4AH battery used = 4 Hour* JP3 installed (factory default) Reader 2 PWR***: READER 2 PWR (terminals 35+ and 36-) Voltage Rating: 12. 5VDC to 11. 7VDC with JP4 set to 12V. Maximum Current: 125mA Battery Standby Time: JP3 not installed and 4AH battery used = 4 Hour* JP3 installed (factory default) Typical Applications: App. [. . . ] Cards GEM-PX Gemini Prox Reader with Access and Alarm Status Indicators GEM-PXC/50 50 Additional Gemini Prox Cards GEM-H1326 HID Prox Reader GEM-H1326C/100 100 Add'l HID Cards 333 Bayview Avenue, Amityville, New York 11701 USA · 1-800-645-9445 · www. napcosecurity. com * UL installations require JP3 to be removed. Preliminary specifications , subject to change. Gemini and GeminiAccess are trademarks of NAPCO. HID and Windows are trademarks of their respective companies. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO ACM1D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO ACM1D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag