User manual NAPCO EN50131-1 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO EN50131-1. We hope that this NAPCO EN50131-1 user guide will be useful to you.

Lastmanuals help download the user guide NAPCO EN50131-1.


Mode d'emploi NAPCO EN50131-1
Download
Manual abstract: user guide NAPCO EN50131-1DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] GEM-P1664 Series: 8 to 64 Zone Hybrid Hardwire/Wireless Controls Suitable for EN50131-1 Installations The GEM-P1664 Series hardwire/ wireless control panel with partitioning ideal to standardize on for both residential & commercial applications! Features: · 8 to 64 hardwire/wireless zones (including two 2-wire fire zones) · Programmable partitioning for up to four areas · Up to 64 users · Supports full range of reliable NAPCO Wireless crystalcontrol transmitters­ proven to outperform leading competitive brands in independent tests!· Choice of custom alphanumeric, digital and icon keypads · Temperature display on keypad (with optional temperature sensor), shown at left. Two configurations for every application requirement: · GEM-P1664EX model suitable for use in EN50131-1 Installations (wall mount transformer not included). [. . . ] · Up to 2 NAPCO helically-filtered, crystalcontrol RF receivers · Interior bypass group with programmable automatic interior bypass · 600 event log · Auto Arm · Uses up to 7 of any of the Classic/RP- or KSeries Stay & Away keypads · Programmable telephone line cut supervision with delay · 3 Keypad panics (F, P, A) · Supports all major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pager · Backup/double/split reporting; three 20-digit telephone numbers · Dynamic battery test · Reports alarms, restores and troubles by zone. · 2 programmable entry delay times · Chime by zone · 8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc. · Supports series zone doubling and Loop supervision using double EOL resistors (feature requires use of GEM-EZM4/8 Multiplex Modules) · Multiplex Expandability with GEM EZM4/8 or GEM EZM8 zone expansion modules · Quickloader up/downloading, including unique unattended method · Choice of RF receivers · Partitioning by area · Event log with open/close suppression · Event log viewable at keypad (total log, burglar alarm log, fire alarm log, system trouble log, o/c log) · Cellphone-style keypad programming of zone descriptions ( text) · Programmable 50Hz Clock Setting · Programmable Daylight Savings Time · Programmable Security Bypass (code required for bypass) · Un-Bypassing while disarmed (code required) · Temperature Display at Keypad (-30 to 600C Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display) · Programmable High/Low Temperature Alarm Reporting (requires feature enabled; zone 6) · 24 Hour day zone trouble · Programmable security blocking of keypad display messages ­Informational displays made visible contingent on user's assigned area(s) within system · Programmable Swinger Shutdown (2 or 3 activations ­ selectable) · Zone Anding/Cross Zoning (Grouping of zones in which sequential zone activation is required to generate an alarm) SPECIFICATIONS · Environmental Classification: Class I (+5C to +40C), Class II (-10C to +40C) and Class III (-25C to +50C) · Input power: 16. 5VAC via Class 2 plug-in 20VA, 40VA or 50VA transformer · Loop voltage: 10-13VDCdc · Loop current: 32. 5mA with 2. 2k ohm EOLR; 5mA for 2-wire fire · Loop resistance: 300 ohm max. ; 50 ohm max for 2-wire fire · Aux & remote power: 12VDC regulated (11. 7 to 12. 5VDC) · Maximum Combined standby current: 650mA · Maximum Alarm current: 2A · Burg. voltage output: 1 · Programmable negative outputs: 2 · Loop response 750ms, programmable 50ms to 2, 000ms POWER (With Type A Power Supply): Grades 1 and 2 Installations with 4AH battery: Maximum combined standby current: 210mA Maximum combined standby current and alarm current: 650mA Grades 1 and 2 installations with 7AHbattery: Maximum combined standby current is: 460mA Maximum combined standby current and alarm current: 500mA Grade 3 installations (requires 7AH battery): Maximum combined standby current is : 110mA Maximum combined standby current and alarm current: 500mA GEM-TEMP64 Optional temperature sensor, for use with either of the two keypads above, programmable for celsius or fahrenheit. Indoor or outdoor temperature display at keypad. GEM-RP2ASe2 Alpha/Icon Keypad (Version 7 firmware+ support required). GEM-K2AS, as above, with STAY and AWAY user functionality. GEM-RP3DGTL Digital Keypad (Version 3 firmware+ support required). GEM-K3DGTL, as above, with STAY and AWAY user functionality. GEM-EZM4/8 Mulitplex Module for 4 to 8 zones expansion (supports series zone doubling and loop supervision using double EOL resistors). GEM-EZM8 8-Zone Mulitplex Module Choice of NAPCO Wireless Receivers & Full Range of NAPCO GEM or Libra Wireless Transmitters (consult manual for selection for your region's frequency): GEM-K4RF Fixed English Language Display Keypad with 32Pt. Built-in Wireless Receiver (Version 2 firmware+). [. . . ] (Firmware Version 9A+) GEM-K1CA, as above, with STAY and AWAY user functionality. (Firmware Version 9A+) 333 Bayview Ave. , Amityville, NY, USA 11701 +1. 631. 842. 9400 · +1 (631) 842-2382 fax www. napcosecurity. com NASDAQ: NSSC email: 4-intl-sales@napcosecurity. com A497 © NAPCO, 6/05 Preliminary specifications subject to change. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO EN50131-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO EN50131-1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag