User manual NAPCO GEM-P800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO GEM-P800. We hope that this NAPCO GEM-P800 user guide will be useful to you.

Lastmanuals help download the user guide NAPCO GEM-P800.


Mode d'emploi NAPCO GEM-P800
Download
Manual abstract: user guide NAPCO GEM-P800

Detailed instructions for use are in the User's Guide.

[. . . ] Using Your GEM-P800 Security System GEMINI TUS STA ED ARM &20387(5, =(' 6(&85, 7< 6<67(0 1 23 4 5 6 7 8 Oi219c page 1 Tuesday, September 16, 1997 08:24 Introduction Congratulations on your purchase of an advanced GEMINI-P800 Security System. Meticulously developed by a leading manufacturer of state-of-the-art security products, this system will provide you with unprecedented peace-of-mind & incorporates some of the most sophisticated features available today. Above all, it has been designed an extra step, to provide all those operating it with very easy, intuitive use. Please carefully review the information contained in this manual, so that you and all potential users of the system familiarize yourselves with its operation, and can therefore take full advantage of GEMINI's many convenience features and amenities. [. . . ] 2 When the fire alarm signals, escape quickly. If it is hot, use your alternate route through the window. If the door is cool, brace your shoulder against it and open it cautiously. Be ready to slam the door if smoke or heat rushes in. Crawl through the smoke, holding your breath. Close the doors again on leaving to help prevent the fire from spreading. 4 Go to your specific outdoor meeting place so you can see that everyone is safe. 5 Call the Fire Department from a neighbor's telephone. 9 Oi219c page 9 Tuesday, September 16, 1997 08:24 Fire Protection Floorplan Draw a plan of your premises below. 10 Oi219c page 10 Tuesday, September 16, 1997 08:24 Special Functions By pressing A followed by the the appropriate key, (do not press simultaneously) these special functions and features can be enabled: Easy Arm (when system is disarmed) The Easy Arm feature allows the system to be armed by followed by . This will allow the easy pressing arming of the system by someone who is not a regular system user. Easy Exit (when system is armed) This function (if programmed) allows an occupant to leave the premises without disarming the system. Pressing followed by while the system is armed will start a 3 minute period, during which you can leave through the Exit/ Entry door. Bell / Battery Test will cause the bell, or Pressing followed by siren to sound for 2 seconds. This will also initiate a test of your battery to make sure it is adequately charged. The P800 also performs an automatic battery test very 24 hours Access Output followed by ll If programmed, pressing activate the Access Output which may be configured to open a door strike, turn on lighting, or activate some other special feature your installer has provided. Display System Trouble ollowed by Pressing is lit will cause the system to display any current system will exit the Display System troubles. Chime Mode On / Off will activate / deactivate Pressing followed by the door chime. Activating this feature will cause any door to beep the keypad sounder when it is opened. Program Mode will enable the "Program Pressing followed by Mode", which will allow you to program and erase user codes. (see Programming user codes, page 14) Keypad Sounder On / Off Pressing followed by will deactivate / activate the keypad sounder, depending on its present state. By deactivating the sounder on a keypad installed in a bedroom, for example, you will only turn off that keypad's sounder. All other keypads on the system will still sound normally. wi f when TROUBLE 11 Oi219c page 11 Tuesday, September 16, 1997 08:24 System Troubles The GEM-P800 is constantly monitoring its own components, as well as all critical services, such as AC power and the telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble does occur, it will caution you by lighting the TROUBLE light and beeping the keypad buzzer. If you cannot immediately clear the system trouble, the system can still be used. [. . . ] After repair or replacement, NAPCO assumes the cost of returning products under warranty. NAPCO shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, improperly installed, improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts of God, or on which any serial numbers have been altered, defaced or removed. NAPCO will not be responsible for any dismantling, reassembly or reinstallation charges. This warranty contains the entire warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO GEM-P800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO GEM-P800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag