User manual NAPCO MVA-1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO MVA-1000. We hope that this NAPCO MVA-1000 user guide will be useful to you.

Lastmanuals help download the user guide NAPCO MVA-1000.


Mode d'emploi NAPCO MVA-1000
Download
Manual abstract: user guide NAPCO MVA-1000

Detailed instructions for use are in the User's Guide.

[. . . ] Your system consists of a control panel (a computer housed within a white metal panel enclosure), one or more GEMINI Decorator Keypads for controlling the system, and various security detection devices. These detection devices are divided among separate areas known as "zones", set up throughout your premises. Each zone number corresponds to a Zone light on your Keypad's display area. When a zone's number is ON (or lit), it indicates that one or more detection device(s) assigned to that area are active or open. [. . . ] Disarming the system with the Ambush Code will cause the system to disarm and simultaneously send a silent ambush alarm signal to Central Station. If your system has the Ambush feature enabled, the code assigned as the User 8 code will function as your Ambush Code. 7 Yes Oi219c page 7 Tuesday, September 16, 1997 08:24 Disarming Your System / Silencing an Alarm Disarming Your System when Returning 1 2 Enter your premises through the Entry/Exit door. The keypad will sound a steady tone to remind you to disarm the system before your Entry Delay time expires. The red Armed light will go out, indicating that the system has been disarmed. Note: If you make a mistake entering your code, press Alarm Indication Silencing an Alarm and re-enter the code, followed by. If the Red Armed light is flashing rapidly, an alarm occurred while you were away. For your own protection, leave immediately and call authorities from a neighbors phone . In the event that the system goes into alarm due to a violated burglary zone, the siren and the keypad sounder will activate and the number of the zone in alarm will flash in the display. To silence the system, enter your User code followed by. The keypad sounder and siren will silence, but the zone in alarm will continue to flash. Press to reset this alarm memory. Silencing a Fire Alarm In the event that the Fire alarm activates due to an violated smoke or fire detector, the bell or siren will sound a distinct pulsating tone. If you cannot immediately clear the system trouble, the system can still be used. Simply press trouble as described below, and then arm the system. To determine the nature of the trouble, press ollowed by count the number of keypad beeps and observe the number of the illuminated zone. Refer to the following table to determine the cause of the trouble. If there is more than one trouble to view, will scroll to the next trouble, and then exit the TROUBLE mode if there are no more troubles to view. pressing Keypad Beeps or lashes 1 Beep F f , followed by t o view the Zone light ON 1 System Trouble Condition AC Power Failure Action This trouble will occur if AC power is not present. Make sure system transformer is plugged into AC receptacle and check the circuit breaker, otherwise call installing company for service. If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If the trouble does not go away in 24 hours, call installing company for service. The system was not able to report to central station. If this is due to a temporary interruption in the telephone service, the trouble can be cleared when the service is restored by pressing ollowed by again to view the trouble, and and then o exit. Otherwise, call installing company for service. [. . . ] Any action for breach of warranty, including but not limited to any implied warranty of merchantab ility, must be brought within the six months following the end of the warranty period. IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured to NAPCO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MVA-1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MVA-1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag