User manual NAPCO P 801 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO P 801. We hope that this NAPCO P 801 user guide will be useful to you.

Lastmanuals help download the user guide NAPCO P 801.


Mode d'emploi NAPCO P 801
Download
Manual abstract: user guide NAPCO P 801DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Gemini P801 SERIES GEM-P801 control includes classic GEMRP8 keypad and transformer; analogous K-P801 includes K-Series numeric keypad & transformer. GEM-P801ALPHA includes GEMRP8LCD custom alpha keypad & transformer Gemini P801 Series: economical 9 zone hybrid now with your choice of numeric or custom alpha keypads. Gemini keypads compatible with the GEMP801 RP8/K800 RP3DGTL RP1CAe2 RP2ASe2 K3DGTL RP8LCD K1CA K2AS K4RF GEMP801 K4 Gemini Manufacturing great security products is all we do. [. . . ] The K-P801 is the control, transformer and numeric keypad with K-Series Stay and Away keys. The Gemini P801 Series features 8 user codes and 50 event log. Plus, it supports all the same standard Gemini Transmitters used with other Gemini panels. Wireless transmitter signal strength is also audibly and visually reported right at the keypad. Programming for the panel is easy with the NAPCO PCD-WINDOWS software. CONTROL PANEL FEATURES: · 9 Programmable Zones, including 2Wire (No Zone Doubling) · 6 Hardwire or Wireless Zones plus: 2 Wireless Zones plus 1 2-Wire Fire Zone Supports all Gemini Transmitters using · Gemini GEMRECVXP8 Wireless Receiver · 8 Individually Reporting User Codes · 50 Event Log · Windows PC Programmable with PCD-Windows · Line- and Bell-Cut Supervision · Up/Downloadable Even with Phone Company Answering Service · Unique Unattended Downloading · All Major Communicator Formats plus Point ID & Pager Format · Programmable Telco Line Cut Supervision · Fuseless, maintenance-free operation · · · · Programmable Bell Cut Supervision Double Reporting & Backup Reporting EZ Wire Full-Size Terminal strips Output: 2A, max. - fire · Designer Keypad Dimensions: 4 3/8" x 5 7/8" pads with Stay and Away functions. · · · · COMMUNICATOR FEATURES: · All Major Communicator Formats including, Point ID, Ademco Slow, Radionics Slow/Fast, Silent Knight Fast, Universal High Speed, 4/2, etc. · Pager Format · Programmable Telco Line Cut Supervision · Programmable Bell Cut Supervision · Double Reporting & Backup Reporting · 8 Individually Reporting User Codes with open/close reporting by user Restoral reporting: AC, Battery, Trouble, · Fire · Reporting: Low Battery, Opening/closing, conditional closing; system, zone report, tamper, wireless smoke supervisory and low battery SPECIFICATIONS: · Operating Temperature: 0- 49 degrees C (32-120 F) Input Power: 16. 5 VAC Plug-in 20VA · Transformer · Loop Voltage: 5 Volts · Loop Current: 1. 1 mA · Loop Resistance: 300 per zone (max. ) · Alarm Output: Burg: 12 VDC, 2A (max. ) Fire: 12 VDC, 65 mA · Combined Standby Current: 500 mA Residential Burglary (4 hour standby) 500 mA Residential Fire (4 hour standby) 120 mA Residential Fire (24 hour standby) · Current Limiting: Burg/Fire: 2. 25 A · Output: 2A, max. -burglar; 125mA, max. -fire · Maximum Charging Current: 165mA · Housing: 11" x 12 1/8" x 3" (H x W x D) · Required Battery: 12V 4 AH or 7 AH Rechargeable · Max. Number of Keypads: 4 (NOTE: Classic GEM-RP8 keypads cannot be intermixed on systems with other key- x 1 1/6" (H x W x D); 11. 1cm x 14. 9cm x 2. 7cm (HWD) Supports All Gemini Wireless Max. Number of Receivers: 2 (GEMRECV-XP8) Max Number of Compatible Smoke Detectors: 10 Max. [. . . ] GEM-K800 Numeric K-Keypad, above, with STAY & AWAY functions GEM-RP8LCD Custom Alphanumeric Keypad with STAY & AWAY functions and 2 Built-in Zones GEMP801ALPHA Panel, transformer & custom alpha keypad, above NAPCO NETLINKTM Intranet/Internet Alarm Reporting Components GEMINIACCESSTM economically add up to 8 doors of access control to Gemini Panels. Several paks are available Compatible with these 3 standard Gemini keypads GEMRP8LCD with Stay & Away and Built-in 2 Zone Expansion Module K800 with Stay & Away Keys GEMRP8 Classic Keypad In North America 1-800-645-9445 · 631-842-9400 333 Bayview Avenue, Amityville, New York 11701 USA · www. napcosecurity. com International 224 Europa Blvd, Gemini Business Park Warrington WA5 7TN England UK 44 (0) 1925242428 Gemini and Wizard are trademarks of Napco. A449B [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO P 801

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO P 801 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag