User manual NAVMAN FUEL 2100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAVMAN FUEL 2100. We hope that this NAVMAN FUEL 2100 user guide will be useful to you.

Lastmanuals help download the user guide NAVMAN FUEL 2100.


Mode d'emploi NAVMAN FUEL 2100
Download
Manual abstract: user guide NAVMAN FUEL 2100

Detailed instructions for use are in the User's Guide.

[. . . ] 4 Fuel Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Other Fuel Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Changing the fuel remaining value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Setting the low fuel alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Individual calibration will increase this level of accuracy to better than 2% over a fuel flow range of 10. 0 to 120 litres per hour. Use the following steps to calibrate your fuel flow meter: 1. Reset the total log value to zero (see previous page). The larger the amount the more accurate the calibration will be. Take note of the actual volume of fuel used and the fuel used indicated by the total log. If these two totals are different the instrument may require calibration. Press and hold the key while applying power ^ V TOTAL Hold down during power up 2. The display will indicate the current display unit with: 3. To select the display unit desired, use the and keys to change the value. To exit this mode, press and hold both the and keys simultaneously for one second. Imperial Gallons ^ US Gallons 5. Release the Litres WOLF Hold down during power up key. Display will flash current total log value. 260 6. Use the or keys to make the display indicate the actual volume of fuel used. Press both keys simultaneously for 1 sec to exit. Press and hold for 1 second The fuel flow meter is now calibrated. Press and hold to exit Information will now be indicated in the selected display unit. 6 NAVMAN FUEL 2100 Installation and Operation Manual 3 Installation WARNING IT IS VERY IMPORTANT TO INSTALL A FUEL FILTER BETWEEN THE FUEL FLOW TRANSDUCER AND THE FUEL TANK. THIS FILTER WILL CATCH LARGER PARTICLES OF DIRT FROM THE FUEL TANK AND PREVENT THE FINE GAUZE FILTER IN THE FUEL FLOW TRANSDUCER FROM BECOMING BLOCKED AS THIS MAY DAMAGE THE ENGINE. Location The FUEL 2100 is designed for above or below deck installation. Select a position that is: · · · · · · On a flat surface At least 300mm (12") from a compass At least 500mm (20") from any radio Easy to read by the helmsman and crew Protected from physical damage Accessible to electrical cable connections Mounting The instrument panel must be 3mm to 19mm (1/8" to 3/4") in thickness. · · · Drill a 51mm (2") hole in the instrument panel. Remove brackets and insert the instrument so the back is flush with the instrument panel. Slide the bracket over the instrument and tighten the mounting nut until secure. Instrument Panel 51mm (2") Hole Mounting Nut Mounting Bracket Instrument Sealing Gasket NAVMAN FUEL 2100 Installation and Operation Manual 7 Wiring Connection · Keep electrical and transducer cables away from alternator or other noise generating electrical cables. Avoid connecting the instrument to power circuits that share loads with ignition, alternators, inverters and radio transmitters. Electrical power supply connections should always be as short as possible. [. . . ] 923/588 Thaprong Road, Alegre - RS, Brasil. Mahachai, Ph: +55 51 3242 9972 Muang, Samutsakhon 74000, e-mail: equinautic@equinautic. com. br Thailand. Ph: +66 34 411 919 MIDDLE EAST Lebanon and Syria Letro, Balco Stores, Moutran Street, Tripoli VIA Beirut. Ph: +961 6 624512 e-mail: balco@cyberia. net. lb United Arab Emirates Kuwait, Oman, Iran & Saudi Arabia Abdullah Moh'd Ibrahim Trading, opp Creak Rd. Ph: +971 4 229 1195 e-mail: mksq99@email. com AFRICA South Africa Pertec (Pty) Ltd Coastal, Division No. 16 Paarden Eiland Rd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAVMAN FUEL 2100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAVMAN FUEL 2100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag